4.2.6.4
Speed Reference (A01.04)
This parameter will automatically define the input terminals for the selections listed below.
(X-Press Programming) for details.
Setting
Description
00
2-Speed Multi-step — Defines Terminal S3 = 2nd speed.
01
3-Speed Multi-step — Defines Terminals S3 and S4 as speeds 2 and 3 respectively.
02
5-Speed Multi-step — Defines Terminals S3-6 as speeds 2-5.
03
2-Step infinitely variable — Terminals S1 and S2 = B01.01 (Reference 1) and speed hold. Terminal
S3 = Accelerate.
04
3-Step infinitely variable — Terminals S1 and S2 = B01.01 (Reference 1). Terminal S3 = Speed Hold.
Terminal S4 =Accelerate.
05
Uni-polar analog — Terminals S1 and S2 = A directional input. Terminal A1 = 0-10V. For 4-20mA
control, configure terminal A2.