7.2 Status Light Indicators and Warnings
7.2.1
Transmitter STATUS Light Indication
Type
Display Type
Indication
1
Solid red
Voltage goes below 1.9V at initial power on -
transmitter power shuts off.
Voltage goes below 1.8V during operation -
transmitter power and receiver MAIN
shut off.
2
1 red blink followed by a 2-
second pause
Voltage goes below 1.85V during operation -
change batteries immediately.
3
2 red blinks followed by a 2-
second pause
The pushbutton is defective after turning on
the transmitter power.
4
No light displayed
When a defective pushbutton condition
occurs (2 red blinks, type 3 above), find out
which pushbutton is defective by pressing all
the pushbuttons on the transmitter one at a
time. If the pushbutton is in good working
order, the LED will not light up when
pressed. If the pushbutton is defective, the
LED will continue to display 2 red blinks
when pressed.
5
3 red blinks followed by a 2-
second pause
EEPROM error
6
4 red blinks followed by a 2-
second pause
Transmitting error; system cannot lock on
to the designated channel.
7
Solid green for up to 2
seconds
Transmitter power on with no faults detected
(prior to initiating the START function)
8
Blinking green
Transmission in progress
9
Slow red blinks
Stop command initiated with receiver MAIN
deactivated
10
1 orange blink every 4
seconds
Transmitter on standby
11
Alternate red and green
blinks
I-CHIP has lost programming. Reprogram
the I-CHIP.