(E)
15
RS97-1024NGZ Series
9-4. Alarms
Th
is product outputs alarm information to the controller based on the errors detected and the results of self-diagnosis.
Contained in the alarms is the bit information which indicates the causes of the alarms referred to as “fault causes,” and
these are defi ned for this product as below.
Name
When OK
When NG
Details
Most signifi cant bit
Functional
safety
redundant
system
statuses
Address00
0
code2
The code indicating details of the location where the redundant
system alarm occurred is stored here. (
※
1)
Address01
0
Address02
0
F2
0
1
Alarm has occurred in the redundant system → 1
Reserved
0
Always 0
Reserved
0
Always 0
Reserved
0
Always 0
PDV2
1
0
Data was transferred normally by the redundant system → 1; otherwise → 0
System Fault
0
1
Electrical circuit trouble or some other internal problem has
occurred in the redundant system → 1
Reserved
0
Always 0
Position FS Fault
0
1
The redundant system has detected a position information error
relating to the functional safety → 1
Reserved
0
Always 0
Reserved
0
Always 0
Reserved
0
Always 0
Reserved
0
Always 0
Reserved
0
Always 0
Primary
system
statuses
Address00
0
code1
Th
e code indicating details of the location where the primary
system
alarm occurred is stored here. (
※
2)
Address01
0
Address02
0
F1
0
1
Alarm has occurred in the primary system → 1
Reserved
0
Always 0
Reserved
0
Always 0
Reserved
0
Always 0
PDV1
1
0
Data was transferred normally by the primary system → 1; otherwise → 0
System Fault
0
1
Electrical circuit trouble or some other internal problem has
occurred in the primary system → 1
Reserved
0
Always 0
Position FS Fault
0
1
The primary system has detected a position information error
relating to the functional safety → 1
Position Fault
0
1
Th
e primary system has detected a position information error other
than one relating to the functional safety → 1
Sensor SY Fault
0
1
A system error has been detected in the interpolation circuit of the
primary system → 1
Sensor OV Fault
0
1
An incremental-type overfl ow has been detected in the interpolation
circuit of the primary system → 1
Sensor AB Fault
0
1
An absolute-type error has been detected in the interpolation circuit
of the primary system → 1
Least signifi cant bit
Sensor LV Fault
0
1
An incremental-type level error has been detected in the
interpolation circuit of the primary system → 1
(
※
1)
code2
Address00
Always 0
Address01
Always 0
Address02
Th
e redundant system FPGA has detected an alarm → 1
(
※
2)
code1
Address00
ASIC of sensor block A has detected an alarm → 1
Address01
ASIC of sensor block B has detected an alarm → 1
Address02
Primary system FPGA has detected an alarm → 1
Содержание RS97-1024NGZ Series
Страница 3: ...RS97 1024NGZ Series J 1...
Страница 4: ...RS97 1024NGZ Series 2 J...
Страница 6: ...ii J RS97 1024NGZ Series...
Страница 9: ...J 3 RS97 1024NGZ Series 1 6 2006 42 EC...
Страница 10: ...4 J RS97 1024NGZ Series 2 MR LSI SIEMENS SIEMENS DRIVE CLiQ...
Страница 11: ...J 5 RS97 1024NGZ Series 3 S N...
Страница 12: ...6 J RS97 1024NGZ Series 4 4 1 SIEMENS DRIVE CLiQ cw CW 4 2 7...
Страница 13: ...J 7 RS97 1024NGZ Series 5 SIEMENS DRIVE CLiQ 7 2 DRIVE CLiQ...
Страница 17: ...J 11 RS97 1024NGZ Series 7 2 SIEMENS DRIVE CLiQ SINUMERIK 4 4SP2 SINAMICS 4 4SP1 SIEMENS...
Страница 18: ...12 J RS97 1024NGZ Series 8 6 3...
Страница 22: ...16 J RS97 1024NGZ Series 9 5 6 16 9 6 20 9 6 18 1 250 m 2 1...
Страница 24: ...18 J RS97 1024NGZ Series...
Страница 28: ...ii E RS97 1024NGZ Series...
Страница 46: ...18 E RS97 1024NGZ Series...
Страница 50: ...ii G RS97 1024NGZ Series...
Страница 69: ...RS97 1024NGZ Series 1...