36
(2)
Input resolution acquisition command
Offset
Label
Setting value (Hex)
0
INC
Please enter an arbitrary value different from the value previously
sent.
1
CMD
0x05
2
RSV1
0x00
3
RSV2
0x00
4
DATA1
※
ASCII code
Axis number
Setting value (Hex)
‘
1
’~’
10
’
0x30
~
0x39
‘
11
’~’
16
’
0x41
~
0x46
5
~
15
DATA2
~
DATA11
Dummy
0x00
(3)
Reference point use setting command
Offset
Label
Setting value (Hex)
0
INC
Please enter an arbitrary value different from the value previously
sent.
1
CMD
0x06
2
RSV1
0x00
3
RSV2
0x00
4
DATA1
※
ASCII code
Axis number
Setting value (Hex)
‘
1
’~’
10
’
0x30
~
0x39
‘
11
’~’
16
’
0x41
~
0x46
5
DATA2
※
ASCII code
Use reference point
Setting value (Hex)
‘
0
’:
OFF
0x30
‘1’:
ON
0x31
6
~
15
DATA3
~
DATA11
Dummy
0x00