16 (E)
5. Siemens: Operations to be performed
using SIMATIC STEP 7
The description in this section uses the Siemens “SIMATIC STEP 7 Basic V13 SP1
Update 9” as the development environment.
This description also uses the Siemens SIMATIC S7-1200 CPU1211C (CPU,
PROFINET RT master) as the network element. The network is constructed locally, and
the IP address of each element is set as a static IP address as shown below.
Table 5-1 Siemens: IP address settings of various equipment used in the description of
SIMATIC STEP 7 introduction
Equipment name
IP address
Subnet mask value
Development computer
192.168.0.1
255.255.255.0
CPU1211C
(
CPU
,
PROFINET RT master
)
192.168.0.12
X20BC00E3
(
PROFINET RT slave
)
192.168.0.101
5.1. Importing the GSDML file
1.
Start up SIMATIC STEP 7, and select “Options”
→
“Manage general station
description files (GSD)” from the “Project view” menu.
Fig. 5-1 SIMATIC STEP 7 -- Importing the GSDML file -- No.1
2.
Select the folder in the displayed window that contains the GSDML file
downloaded in section 3 above.
After that, select “GSDML-V2.25-BR-X20BC00E3-20160415.xml” from “Content
of imported path”, and click “Install”.
Fig. 5-2 SIMATIC STEP 7 -- Importing the GSDML file -- No.2
1. Select Folder
2. Check
3. Push Button