Magnescale MG70-PN Скачать руководство пользователя страница 1

MG70-PN

取扱説明書

 / Instruction Manual

PROFINET RT インターフェイスユニット メインモジュール

 / 

PROFINET RT Interface unit Main module

お買い上げいただき、ありがとうございます。
ご使用の前に、この取扱説明書を必ずお読みください。
ご使用に際しては、この取扱説明書どおりお使いください。
お読みになった後は、後日お役に立つこともございますので、必ず保管してください。

Read all the instructions in the manual carefully before use and strictly follow them. 
Keep the manual for future references.

Содержание MG70-PN

Страница 1: ...G70 PN Instruction Manual PROFINET RT PROFINET RT Interface unit Main module Read all the instructions in the manual carefully before use and strictly follow them Keep the manual for future references...

Страница 2: ......

Страница 3: ...5 4 B R Automation Studio 6 4 1 GSDML 6 4 2 IP 8 4 2 1 8 4 2 2 12 4 3 MG71 CM 13 4 4 15 4 4 1 15 4 4 2 15 5 SIMATIC STEP 7 16 5 1 GSDML 16 5 2 IP 18 5 2 1 18 5 2 2 21 5 3 MG71 CM 22 6 I O 24 6 1 X20PS...

Страница 4: ...2 J 1 MG70 PN Bernecker Rainer Industrie Elektronik B R PROFINET RT MG70 PN MG71 CM B R Automation Studio SIMATIC STEP 7 MG70 PN MG71 CM B R...

Страница 5: ...N 2 1 2 1 Magnescale B R MG70 PN X20BC00E3 1 X20BB80 1 X20PS9400 1 X20TB12 1 PROFINET RT 1 MG71 CM X20DC11A6 1 X20BM11 1 X20TB12 1 1 1 DK800S Series or DK10 25 50 100 Series DK800S Series 1 DK10 25 50...

Страница 6: ...4 J 2 2 2 1 MG70 PN MG70 PN RJ45 8P8C X20BB80 X20PS9400 X20TB12 X20TB12 X20DC11A6 X20BC00E3 Ethernet MG70 PN RJ45 DC24V GND MG70 PN X20BM11 MG71 CM...

Страница 7: ...R http www br automation com Downloads Product Groups Networks and fieldbus modules Networks and fieldbus modules PROFINET PROFINET Bus controllers Bus controllers X20BC00E3 Profinet Buscontroller GSD...

Страница 8: ...ation Studio IP IP 192 168 0 1 255 255 255 0 X20CP3585 CPU 192 168 0 11 X20IF10E1 1 PROFINET RT 192 168 0 20 X20BC00E3 PROFINET RT 192 168 0 101 4 1 GSDML 1 Automation Studio Tools Import DTM Device 4...

Страница 9: ...7 J 4 DTM 4 3 Automation Studio GSDML No 3 5 Output DTM catalog update successfully finished 4 4 Automation Studio GSDML No 4 6 Hardware Catalog Catalog X20BC00E3 4 5 Automation Studio GSDML No 5...

Страница 10: ...Physical View Profinet DTM X20BC00E3 X20CP3585 PROFINET RT I F X20IF10E1 1 4 6 Automation Studio IP No 1 2 X20IF10E1 1 Profinet DTM Device Configuration 4 7 Automation Studio IP No 2 3 Navigation Area...

Страница 11: ...55 0 Gateway address IP 4 9 Automation Studio IP No 4 5 Navigation Area Ethernet Devices Use Network Connections for Scan 4 10 Automation Studio IP No 5 6 X20BC00E3 Device 7 Search Devices Devices Onl...

Страница 12: ...e New device name brpn001 X20BC00E3 4 12 Automation Studio IP No 7 9 IP Set IP Address Use static IP Address IP Address Subnet mask Set Address IP Address 192 168 0 101 Subnet mask 255 255 255 0 Gatew...

Страница 13: ...11 J 10 Search Devices IP 4 14 Automation Studio IP No 9 Web IP X20BC00E3 Web server 4 15 Automation Studio IP No 10...

Страница 14: ...on Area Device Table Device X20BC00E3 X20BC00E3 Name of station 4 2 1 8 Apply 4 16 Automation Studio IP No 1 2 Navigation Area IP Address Table Name of station 1 X20BC00E3 4 17 Automation Studio IP No...

Страница 15: ...ew X20BC00E3 MG70 PN MG71 CM 1 Physical View X20BC00E3 Device Configuration 4 19 Automation Studio MG71 CM No 1 2 Navigation Area Modules 4 20 Automation Studio MG71 CM No 2 3 Add Module 1 MG71 CM 4 2...

Страница 16: ...22 Automation Studio MG71 CM No 4 5 X20DC11A6 X20DC11A6_C1 Submodule details Dataset Parameter X20DC11A6 B R PROFINET RT User s manual 4 23 Automation Studio MG71 CM No 5 6 OK Apply Physical View X20B...

Страница 17: ...ation Navigation Area Controller Settings Process image storage format OK Apply 4 24 Automation Studio 4 4 2 Profinet DTM X20BC00E3 Device Configuration Navigation Area Modules X20BC00E3 X20BC00E3 Dat...

Страница 18: ...MATIC S7 1200 CPU1211C CPU PROFINET RT 192 168 0 12 X20BC00E3 PROFINET RT 192 168 0 101 5 1 GSDML 1 SIMATIC STEP 7 Project view Options Manage general station description files GSD 5 1 SIMATIC STEP 7...

Страница 19: ...17 J 3 GSDML Close 5 3 SIMATIC STEP 7 GSDML No 3 5 4 SIMATIC STEP 7 GSDML No 4 4 5 5 SIMATIC STEP 7 GSDML No 5 5 Devices networks Hardware catalog X20BC00E3 5 6 SIMATIC STEP 7 GSDML No 6...

Страница 20: ...7 5 2 1 X20BC00E3 0x00 X20BC00E3 1 SIMATIC STEP 7 Project view Online access X20BC00E3 Update accessible devices 5 7 SIMATIC STEP 7 IP No 1 2 X20BC00E3 Accessible device MAC Address Online diagnostics...

Страница 21: ...255 255 0 Use router Router address IP X20BC00E3 IP 5 9 SIMATIC STEP 7 IP No 3 4 X20BC00E3 Assign name PROFINET device name Assign name PROFINET device name brpn001 X20BC00E3 5 10 SIMATIC STEP 7 IP No...

Страница 22: ...20 J 5 Update accessible devices 3 4 IP 5 11 SIMATIC STEP 7 IP No 5 Web IP X20BC00E3 Web server 5 12 SIMATIC STEP 7 IP No 6...

Страница 23: ...No 1 2 Device view X20BC00E3 Ethernet addresses IP protocol IP address 5 2 1 3 PROFINET Generate PROFINET device name automatically PROFINET device name 5 2 1 4 5 14 SIMATIC STEP 7 IP No 2 1 Select E...

Страница 24: ...G71 CM 1 Devices networks Device View X20BC00E3 5 15 SIMATIC STEP 7 MG71 CM No 1 2 Hardware catalog X20DC11A6_C1 MG71 CM X20DC11A6 1 MG71 CM 5 16 SIMATIC STEP 7 MG71 CM No 2 Added Double Click 1 Open...

Страница 25: ...23 J 3 X20DC11A6 X20DC11A6_C1 Module parameters X20DC11A6 B R PROFINET RT User s manual 5 17 SIMATIC STEP 7 MG71 CM No 3...

Страница 26: ...8Bit 1Byte 6 1 X20PS9400 6 1 GSDML X20PS9400 I O I O I O I ModuleOK Unsigned8 x 0 Inputs_X20PS9400_a StatusInput01 Bool x 1 0 StatusInput02 Bool x 1 2 SupplyCurrent Unsigned8 x 2 SupplyVoltage Unsign...

Страница 27: ...teger32 x 9 O Outputs_X20DC11A6_C1_a BW_QuitChannel_A Bool y 0 0 BW_QuitChannel_B Bool y 0 1 BW_QuitChannel_R Bool y 0 2 Outputs_X20DC11A6_C1_b Encoder01Reset Bool y 1 0 Encoder01LatchEnable Bool y 1...

Страница 28: ...ot avoided may result in minor or moderate injury or property damage z Cautions Caution Do not attempt to take any unit apart while the power is being supplied Doing so may result in electric shock Do...

Страница 29: ...ss and the device name 8 4 2 1 Main unit side 8 4 2 2 Project side 12 4 3 Configuration setting for MG71 CM 13 4 4 Communication settings 15 4 4 1 Master side 15 4 4 2 Slave side 15 5 Siemens Operatio...

Страница 30: ...evelopment environment B R Automation Studio Siemens SIMATIC STEP 7 when introducing the MG70 PN and MG71 CM digital gauges For information concerning the MG70 PN and MG71 CM refer to the correspondin...

Страница 31: ...el number Description Appearance Qty MG70 PN X20BC00E3 1 X20BB80 1 X20PS9400 1 X20TB12 1 PROFINET RT Interface unit Main module slave 1 MG71 CM X20DC11A6 1 X20BM11 1 X20TB12 1 Counter module 1 Supplie...

Страница 32: ...should be shielded in accordance with the operating environment Use a shielded RJ45 8P8C connector as the MG70 PN side connector X20BB80 X20PS9400 X20TB12 X20TB12 X20DC11A6 X20BC00E3 Ethernet cable MG...

Страница 33: ...ct Downloads Product Groups Networks and fieldbus modules Networks and fieldbus modules PROFINET PROFINET Bus controllers Bus controllers X20BC00E3 Download Profinet Buscontroller GSD Package 2 Save t...

Страница 34: ...ion Studio introduction Equipment name IP address Subnet mask value Development computer 192 168 0 1 255 255 255 0 X20CP3585 CPU 192 168 0 11 X20IF10E1 1 PROFINET RT master 192 168 0 20 X20BC00E3 PROF...

Страница 35: ...ML file No 3 5 The update is complete when the message DTM catalog update successfully finished appears in the Output pane Fig 4 4 Automation Studio Importing the GSDML file No 4 6 X20BC00E3 can now b...

Страница 36: ...0x00 before supplying power to the X20BC00E3 The development computer and the X20BC00E3 should be connected 1 Add X20BC00E3 under Profinet DTM on Physical View in the Automation Studio This manual des...

Страница 37: ...example in this manual IP address is set to 192 168 0 20 and Network mask is set to 255 255 255 0 When using a router set Gateway address to the IP address of the router Fig 4 9 Automation Studio Set...

Страница 38: ...s value matches the MAC address value printed on the main unit Fig 4 11 Automation Studio Setting the IP address and the device name main unit side No 6 8 At the default setting the X20BC00E3 device n...

Страница 39: ...IP address of the router The IP address of the X20BC00E3 will be set Fig 4 13 Automation Studio Setting the IP address and the device name main unit side No 8 10 Click Search Devices again and check t...

Страница 40: ...mation Studio Setting the IP address and the device name project side No 1 2 Select IP Address Table from Navigation Area Of the displayed devices the device with Name of station set to the character...

Страница 41: ...he displayed menu Fig 4 19 Automation Studio Configuration setting for MG71 CM No 1 2 A new tab will open After the tab opens it appears as shown below Check that Modules is selected in Navigation Are...

Страница 42: ...A6_C1 and select the displayed line Submodule details will become active so set Dataset to Parameter The parameters that can be set will be displayed in a list For a description of the parameters regi...

Страница 43: ...tting on the master side can be switched by Process image storage format After switching the setting click OK or Apply Fig 4 24 Automation Studio Communication settings master side 4 4 2 Slave side Op...

Страница 44: ...IC STEP 7 introduction Equipment name IP address Subnet mask value Development computer 192 168 0 1 255 255 255 0 CPU1211C CPU PROFINET RT master 192 168 0 12 X20BC00E3 PROFINET RT slave 192 168 0 101...

Страница 45: ...the GSDML file No 3 Fig 5 4 SIMATIC STEP 7 Importing the GSDML file No 4 4 The hardware catalog will be automatically updated Wait until the update is complete Fig 5 5 SIMATIC STEP 7 Importing the GSD...

Страница 46: ...0E3 The development computer and the X20BC00E3 should be connected 1 Start up SIMATIC STEP 7 expand Online access with Project view further expand the Ethernet interface on the side of the development...

Страница 47: ...s of the router The X20BC00E3 IP address will be set Fig 5 9 SIMATIC STEP 7 Setting the IP address and the device name main unit side No 3 4 The X20BC00E3 device name is also not set at the factory de...

Страница 48: ...above has been added Fig 5 11 SIMATIC STEP 7 Setting the IP address and the device name main unit side No 5 This can also be checked by opening the Web browser entering the set IP address in the URL...

Страница 49: ...om the left menu Set IP address of IP protocol in the Properties tab to the value set in step 3 of section 5 2 1 above In addition remove the check from the Generate PROFINET device name automatically...

Страница 50: ...and select the X20BC00E3 from Device View Fig 5 15 SIMATIC STEP 7 Configuration setting for MG71 CM No 1 2 Find and double click X20DC11A6_C1 from the Hardware catalog pane The MG71 CM X20DC11A6 can b...

Страница 51: ...ties tab and open Module parameters from the left menu The various parameters can be edited from this page For a description of the parameters registers refer to the X20DC11A6 data sheet and the B R P...

Страница 52: ...ccording to the development environment 0 0 Bit 0 of address 0 x 0 Bit 0 of address x x 8 0 Bit 8 to bit 0 of address x 8 Bit 1 Byte 6 1 X20PS9400 Table 6 1 Address map of I O data of X20PS9400 define...

Страница 53: ...der01Latch Integer32 x 9 O Outputs_X20DC11A6_C1_a BW_QuitChannel_A Bool y 0 0 BW_QuitChannel_B Bool y 0 1 BW_QuitChannel_R Bool y 0 2 Outputs_X20DC11A6_C1_b Encoder01Reset Bool y 1 0 Encoder01LatchEna...

Страница 54: ...ent l usage des acqu reurs de l quipement d crit dans ce manuel Magnescale Co Ltd interdit formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des op...

Страница 55: ...ers Note This product or technology may be restricted by the government in your country Please make sure that end use end user and country of destination of this product do not violate your local gove...

Отзывы: