![Magnescale LY71 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/magnescale/ly71/ly71_quick-reference-manual_3584789005.webp)
5/9
LY71 with LX71-KR comparator function
Open collector output
4-3. I/O signal connection
1pin
1pin
Open collector output
Relay output
Wiring of connector with terminal block :
The wire size that can be connected on this terminal
block is AWG26 to 20. Remove 8mm of outer sheath, and
while pressing
Ⓐ
in the terminal hole with a flat-blade
screwdriver, insert it until the wire is placed, and then
remove the screwdriver.
Cable :
For the output cable, use a cable with a shield structure equivalent to
AWG26 to 20 as shown in the figure below. Fix the shielded wire to the
expansion unit fixing screw on the LY71 side.
Input connector
(set number, latch input)
Shielded wire processing :
Connect the shielded wire on the expansion unit side to either of the
two screws that secure the expansion unit. Of course, the LY71 body
must be firmly grounded. If the connector case used on the device side
is of the type that contacts the FG, connect the shielded wire to the
connector case. If not, wire the shield with a lead wire so that it drops
on the FG on the device side.
1pin
Number
Signal
Judgement
①
*OC0
Output 0
②
*OC1
Output 1
③
*OC2
Output 2
④
*OC3
Output 3
⑤
*OC4
Output 4
⑥
COM
ー
Output connector pin assignment
Open collector output
Relay output
Display unit side
+V
Pin 1 to Pin 5
Terminal
Output circuit
Pin 6
Relay output
Number
Signal
Judgement
①
*RY0
Output 0
②
*RY0
③
*RY1
Output 1
④
*RY1
⑤
*RY2
Output 2
⑥
*RY2
⑦
*RY3
Output 3
⑧
*RY3
⑨
*RY4
Output 4
⑩
*RY4
Terminal
Contact the shield with
the connector case
Treat the shield
with leads
Connection processing of
shield with lead wire
Output signal rating :
Rated working voltage: AC100, DC24V
Rated working current: (resistive load) 0.3A
Operating time: Approximately 2ms
Recovery time: Approximately 1ms
Electrical life: 100,000 times or more
Output signal rating :
Voltage: DC12V-24V
Current: up to 15mA
Equivalent to AWG 26 to 20
8mm
Cable cross section
Outer sheath
Shield
Accessories
Output circuit
Display unit side
Output connector pin array
Output connector pin assignment