Specifications

Tank Capacity ...............................................  220 ml (0.9 cups) - min 142 ml (0.6 cups), Max 187 ml (0.8 cups)
Tank Size .............................................................................................................................................. 3.0 x 3.0 x 1.9 inches
Cleaning Cycle ........................................................................................................................................................5 minutes
Auto-Timer Shut Off .......................................................................................................................................................... Yes
Ultrasonic Frequency ..........................................................................................................................................36~40 Khz
Tank Material ..................................................................................................................................Stainless Steel SUS304
Thermal Switch..................................Activates if cleaner reaches 122°F (50°C). Deactivates after 10-15 min
Power Input .......................................................................................................................AC 100V-240V, 50/60Hz, 25W
Power Cable Length .......................................................................................................................................... 61.0 inches
Dimensions ......................................................................................................................................... 4.3 x 4.2 x 5.0 inches
Weight ............................................................................................................................................................................2.25 lbs
Product Certifications ............................................................................................................. LVD, FCC, ICES, cETL/ETL

FAQ/Troubleshooting

Cleaner is not turning on

A. 

Please check that the unit is plugged in and the LED indicator lights up blue when the power 
button is pressed.

B. 

If your cleaner was running for too long, it may have triggered the thermal switch. The 
thermal switch is activated when this cleaner reaches a temperature of 122°F (50°C). If the 
thermal switch is triggered, the LED indicator will turn red. Please allow 10-15 minutes for 
your cleaner to cool down and the thermal switch to turn off. The red LED indicator will turn 
off entirely once the thermal switch is off. You will then be able to use your cleaner again.

Items are not clean

A. 

We recommend adding a bit of liquid dish soap to the water to get rid of any stubborn dirt 
and grime. For cleaning tarnished gold, copper, or silver, please refer to page 6 for enhanced 
cleaning instructions.

IMPORTANT: Do not operate the cleaner without at least 142ml (0.6 cups) of liquid inside the tank. 
Damage to the unit could occur.

Содержание UC21

Страница 1: ...r your purchase of this Magnasonic product Please read this user manual carefully before using product to ensure proper use Keep this manual in a safe place for future reference magnasonic com support...

Страница 2: ...e using six key fundamentals superior quality performance simplicity style value and a fanatical obsession with outstanding customer service At Magnasonic our mission is a simple one create people dri...

Страница 3: ...Contents What Can Be Cleaned 4 Product Information 5 Using Your Cleaner 6 Care and Maintenance 7 Specifications 8 FAQ Troubleshooting 8 Magnasonic Warranty 9 Important Safety Precautions 10 FCC IC Inf...

Страница 4: ...r items that have tarnish see special instructions on page 7 Other Items tools watch parts coins key chains valves machine nozzles badges instruments filters and kitchen utensils Items NOT suitable fo...

Страница 5: ...5 Product Information MAX MIN Touch Sensitive Power Button Power Cord LED Indicator Minimum Fill Line 142 ml Maximum Fill Line 187 ml...

Страница 6: ...tely normal during the cleaning cycle You also may notice slight rippling in the water during the cleaning process 6 This ultrasonic cleaner has an automatic shut off feature and will stop running onc...

Страница 7: ...dd clean water Run for another 5 minutes to remove chemical residue Tarnished Silver Items 1 For items that are not tarnished heavily use a silver cleaning cloth to rub off tarnish then clean followin...

Страница 8: ...button is pressed B If your cleaner was running for too long it may have triggered the thermal switch The thermal switch is activated when this cleaner reaches a temperature of 122 F 50 C If the ther...

Страница 9: ...nstallation or inappropriate use as outlined in the owner s manual B Any Magnasonic product tampered with modified adjusted or repaired by any party other than Magnasonic C Any cosmetic damage to the...

Страница 10: ...st Do not spray water or liquid over the device Never operate the device unattended Do not use components unapproved by the manufacturer Do not use if the power cord is damaged Do not disassemble the...

Страница 11: ...ot occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encoura...

Страница 12: ...magnasonic com...