D-2000 Series
Revised March 2020
Page | 5-2
Table 5-1: TROUBLESHOOTING GUIDE
Issue
Probable Cause
Remedy
No line voltage at all.
Green power indicator
light not on.
1. External fused disconnect
switch off.
2. Fuse in external fused discon-
nect switch blown.
3. Fuse 1FU blown.
4. Green power indicator lamp
burned out.
1. Turn on external fused disconnect switch.
2. Replace fuse. Check for shorts if fuse continues
to blow.
3. Replace fuse 1FU. Check for shorts if fuse
continues to blow.
4. Replace lamp.
No convenience outlet
power. Internal power
on.
1. Fuse 4FU blown.
1. Replace fuse 4FU. Check for shorts if fuse
continues to blow.
Pump motor does not
operate.
1. Fuse 6FU or 7FU blown.
2. Relay 2CR not functioning.
NOTE: Pump is external.
1. Replace fuse 6FU or 7FU. Check for shorts if
fuse continues to blow.
2. Check 115v on wire 14 (Wire 15 for XL units).
Replace 2CR.
Headstock does not
extend to clamp part
or retract to release
part.
1. Air supply not properly con-
nected.
2. Defective foot switch/dual
palm cable and/or plug.
3. Defective solenoid valve,
2SOL.
4. Fuse 8FU.
5. No power at 1PS, 24VDC
power supply
1. Connect air supply to inlet (90psi). Note:
Pressure Regulator setting (min 40 psi)
2. Check Input, I-00, light on PLC. If it doesn’t light
when Footswitch pressed, replace foot switch
cable and/or plug.
3. Check that Output, O-14, light on PLC toggles
with Footswitch. If so, replace solenoid valve
2SOL or complete solenoid valve.
4. Replace fuse, 8FU.
5. Replace 24VDC power supply
Current Flow with
nothing clamped.
1. Insulators worn or missing.
2. SCR(s) shorted.
1. Check headstock drawing for insulator locations
and repair/replace as needed.
2. Check SCR. Contact an Authorized Service
Center.
Irregular clamping
action at headstock.
1. Dirty or defective pressure
regulator.
2. Dirty air filter.
1. Clean or replace pressure regulator.
2. Clean air filter.
No output current at
Contacts, Coil.
1. Thermo shutdown.
2. Loss of Phase on Firing
Board 1.
3. Fuses 7FU, 8FU, and/or 9FU
blown.
4. Check for Inhibit light on
Firing Board goes out during
mag shot.
1. Turn off disconnect, wait until unit cools.
2. Check for Phase Loss Light ON/investigate
problem.
3. Replace blown fuses.
4. See Troubleshooting Stack (Firing Board)
Section above.
Continuous mag shot
on coil and/or contact.
1. Shorted SCR.
1. Call Authorized Service Center.
Main fuse to unit
blown.
1. Shorted SCR
1. Call Authorized Service Center.
Содержание D-2000 Series
Страница 1: ...D 2000 Series Revised March 2020 Page 1 0 D 2000 SERIES ...
Страница 9: ...D 2000 Series Revised March 2020 Page 1 8 PAGE LEFT BLANK INTENTIONALLY ...
Страница 20: ...D 2000 Series Revised March 2020 Page 2 11 PAGE LEFT BLANK INTENTIONALLY ...
Страница 23: ...D 2000 Series Revised March 2020 Page 3 3 Figure 3 4 Figure 3 5 10 11 12 14 13 1 17 2 18 19 15 16 20 23 21 22 ...
Страница 33: ...D 2000 Series Revised March 2020 Page 3 13 PAGE LEFT BLANK INTENTIONALLY ...
Страница 40: ...D 2000 Series Revised March 2020 Page 4 7 PAGE LEFT BLANK INTENTIONALLY ...
Страница 45: ...D 2000 Series Revised March 2020 Page 5 5 PAGE LEFT BLANK INTENTIONALLY ...
Страница 48: ...D 2000 Series Revised March 2020 Page 6 3 PAGE LEFT BLANK INTENTIONALLY ...