A-2045 Series
© 2015 Magnaflux
Page 2
Magnaflux-SRVC-IG002
Issued: Apr 2015
Rev. 2
1. A minimum of two feet is required at both ends and the rear of the inspection unit to ensure
adequate space for servicing (removing machine panels and accessing the circulating
pump) and ventilation.
2. A firm, reasonably level floor capable of supporting the inspection unit and the materials
awaiting inspection.
3. Adequate space to accommodate a black light inspection canopy (Optional), material stor-
age, material movement and access to the materials.
4. A power source of the proper voltage, frequency and phase (as designated on the
Mag-
naflux Data Plate
located on headstock end of inspection unit) capable of providing current
per the nameplate. Connect the incoming power to the Incoming Power Connection located
inside the unit on the back side. Attach the Chassis Ground wire to the inside of the unit to
the Chassis Ground Connection Screw. Follow all local electrical codes for wiring. It is high-
ly recommended that an electrical fused disconnect be installed on the headstock side of
the unit—Either on the wall behind the unit or on a pedestal near the unit. See page 3 for
correct fuse sizes.
Operating Manual and
Drawings
The manual is shipped with the unit in electronic format wrapped
in a green bubble wrap mailer within the Accessories Box. In the
manual is an extensive step by step process of how to assemble
the enclosure and attach it to the unit.
Getting Started
Air Pressure
Regulator
Front of Unit:
Back of Unit:
120VAC receptacle
for pump
Incoming Power
Connection
Chassis Ground
Connection
Incoming Air Connection
1/8” NPT Thread
Set-Up
continued on Page 3...