5

Power Door Lock/Unlock Activation

3 Wire Positive Trigger Door Lock System

87

87A

85

86

30

87

87A

85

86

30

Black Wire Unlock

Red Wire Lock

To +12 Volts

(B)

Existing Power Lock/Unlock Switch

Lock

Unlock

To Existing Power Lock System

12V

3 Pin Black

Plug

Orange Wire

Note: No Connection on Orange Wire

5 Wire Ground at Rest Door Locking Systems

87

87A

85

86

30

87

87A

85

86

30

To +12 Volts

(B)

To Power

Lock Switch

To Power

Lock Motors

White Wire: Lock

Green Wire: Lock

Blue Wire: Unlock

Brown Wire: Unlock

Black Wire Unlock

Red Wire Lock

3 Pin Black Plug

Orange Wire

Note: No Connection

on Orange Wire

Violet Wire: 

ALA-DL1

Relay Pack

3 Wire Ground Trigger Door Lock System

(-) Lock Out

Ground Input

(-) Unlock Out

Black Wire: Connect to Unlock

Red Wire: Connect to Lock

To Door Lock

Control Relays

Orange Wire: No Connection

Lock Control

Switch

3 Pin Black

Plug

Step 5: Optional Accessory Connections

Note: Prewired Door Lock

Interconnect T-Harness are

Available for Most Vehicles

Single Zone Electronic Sensor Plug

Red Wire: +12 Volt Sensor Power Supply

Green Wire: No Connection

Black Wire: Sensor Ground Supply

Blue Wire: Sensor Alarm Trigger Input

4 Pin White Plug

Содержание Carbine PLUS-3000

Страница 1: ...yright 2000 Magnadyne Corporation INSTALLATION MANUAL R Vehicle Security For Technical Assistance 800 638 3600 For Fax on Demand Technical Assistance 800 994 9977 Must be a Registered Dealer to Use Fa...

Страница 2: ...of the vehicle In many cases you can ground the black wire to one of the screws used to secure the siren Run the remaining brown wire through the fire wall to the location of the alarm control module...

Страница 3: ...om the siren for proper operation Blue Wire Optional Grounding Sensor Input The blue wire is an instant grounding trigger input for optional hood trunk grounded pin switches or any electronic sensor G...

Страница 4: ...wire is 10 Amp max Do not exceed this limit or damage to the alarm and parking light relay will result Pink Parking Light Relay Input The pink wire is the input to the flashing parking light relay The...

Страница 5: ...ue Wire Unlock Brown Wire Unlock Black Wire Unlock Red Wire Lock 3 Pin Black Plug Orange Wire Note No Connection on Orange Wire Violet Wire ALA DL1 Relay Pack 3 Wire Ground Trigger Door Lock System Lo...

Страница 6: ...ne wire to lock and unlock the doors Example When the door lock controller sees a signal thru a resistor it will unlock If a signal is received without a resistor the doors will lock Some use 2 resist...

Страница 7: ...ay pack E Plug in the orange 2 pin plug into the orange socket located at the rear of alarm module To test the dual circuit disable system refer to the starter disable testing procedures located in th...

Страница 8: ...ated in the side of the control module 87 86 85 30 White Wire with Black Stripe SPST ALA984H Relay Not Supplied Output to Power Trunk Switch To Constant 12 Volts Input to Relay or Insert White Wire wi...

Страница 9: ...The siren will chirp 1 time You are now in the transmitter code programming mode The LED will be a solid RED S t e p 5 Valet Override Switch 1x 2x Push Arm Disarm Regular or Lock Button Code Hopping T...

Страница 10: ...e Valet Override Switch is in the Off Position S t e p 1 Switch in Off Position Switch in On Position Valet Override Switch R Disarm the Security System The LED will be off and the horn siren will emi...

Страница 11: ...Door will Lock 3 seconds after Ignition is Turned On or Door Locks Door will not Unlock when Ignition is Turned Off LOCK UNLOCK 2 Beeps Door will Lock 3 seconds after Ignition is Turned On Door will U...

Страница 12: ...there are no disarming chirps When you disarm the alarm when the siren is off there will be disarming chirps 4 Follow procedures 2 and 3 for all other protected entrances Step 9 General Testing About...

Страница 13: ...ll hear a single chirp The alarm is now armed 6 The LED will flash at a regular rate indicating an armed condition Note When the automatic arming feature is activated so is the RF tamper re arm circui...

Страница 14: ...key back to the start position and the engine will crank over and start LED Status Indicator Operation LED is off Alarm is disarmed LED is flashing Alarm is armed LED is flashing in a 2 flash hold seq...

Страница 15: ...lash fast Automatic arming indicator 4 Wait 60 seconds and the alarm will become rearmed 5 Repeat steps 1 through 4 When the LED starts flashing fast open one of the protected entrances door the LED w...

Страница 16: ...tically Arms Pink Wire Parking Lights Relay Input Red White Wire Parking Lights Relay Output Violet Wire Positive Door Pin Trigger Input Green Wire Negative Door Pin Trigger Input Blue Wire Negative A...

Отзывы: