19
www.magmaweld.com
USER MANUAL | KULLANIM KILAVUZU
RS 350 MK PRO
EN
Pnt Mode
Welding starts as soon as the trigger is pressed and welding continues for the specified
on-time period and stands by during the length of off-time; the process continues as
long as the button is pressed. Welding will also be terminated when the trigger is
released.
If pnt is selected in the Trigger mode, the On and Off times as well as the welding and
standby times are determined.
On time (Ont)
In pnt mode, the time the welding is active will be set. During this time, the welding will
continue and the welding will stop at the end of the period.
Setting range:
0 - 10 sec.
Off Time (OFt)
Stand-by time during welding is adjusted in pnt mode. During the set time, the welding
will stop and restart at the end of the period.
Setting range:
0 - 10 sec.
Standby Mode (SLC)
When the machine is not used after the time set for sleep mode, it goes into standby
mode. This prevents unnecessary energy consumption.
Setting range:
On - Off
Soft Start (SoS)
When the source is first started, the wire speed rises slowly from the lowest speed until
reaching the set speed. By this means, backlash and spatters are prevented at the
beginning of the welding process.
Setting range:
On - Off
Cooling Time (Cot)
After the use of machine has been completed, the water-cooling unit continues to
operate for the set period of time. This prevents hot water from damaging the torch.
Setting range:
4 - 10 min.
Operation
Содержание RS 350 MK
Страница 1: ...RS 350 MK PRO 90 444 93 53 magmaweld com info magmaweld com 90 538 927 12 62 USER MANUAL...
Страница 3: ...EN MIG MAG WELDING MACHINE TR MIG MAG KAYNAK MAK NES 3 RS 350 MK PRO...
Страница 33: ...33 www magmaweld com USER MANUAL KULLANIM KILAVUZU RS 350 MK PRO EN RS 350 MK PRO Annex...
Страница 63: ...63 www magmaweld com TR USER MANUAL KULLANIM KILAVUZU RS 350 MK PRO RS 350 MK PRO Ekler...
Страница 64: ......
Страница 65: ......
Страница 66: ......
Страница 67: ......