27
www.magmaweld.com
USER MANUAL | MANUEL D’UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
RS 200 MK - RS 250 MK - RS 300 MK - RS 350 MK - RS 400 MK
EN
Fan is not operating
Machine operates noisily
Unstable and / or non-adjustable
welding current
Heater outlet is not operating
• Check the fuse
• Contact the authorized service
• Contact the authorized service
• Check the fuse. Contact the
authorized service
• The fuse has blown
• Contactor failure
• Diode group failure
• The fuse has blown
• Fan motor failure
• Contact the authorized service
4.4 Fuses
Fuse
Amperage
Feature
Protected Circuir
F1
10 A
Fast
Motor and Card of the Wire Feeder
Cooler Fan
CO
2 Heater
Card of Voltmeter / Ampermeter
Delayed
Fast
Fast
1 A
1 A
1 A
F2
F3
F4
Failure
Reason
Solution
Maintenance and Service
Err
Error Code
Error
Cause
Solution
• Check visually whether the fan is
working or not
• If the problem continues, contact the
authorized service
• Open the front of the air ducts
• If the problem continues, contact the
authorized service
• Fan may not be working
• The front of the air inlet-outlet ducts
may be blocked
• The machine working environment
may be too hot or stuffy
• The uptime of your machine may have
been exceeded
• Make sure that the working
environment of the machine is not
excessively hot or stuffy
• If the problem continues, contact the
authorized service
• Allow the machine to cool down by
waiting for a while. If the fault
disappears, try to use the machine at
lower amperage values
• If the problem continues, contact the
authorized service
Thermal
Protection
Water Cooling
Unit Error
• Check water cooling unit connector
and torch inlets/outlets
• Make sure there is water circulation
• If the problem continues, contact the
authorized service
• There may be an error in the water
cooling unit
4.5 Error Codes