18
www.magmaweld.com
proSTICK 200i
EN
USER MANUAL | MANUEL D’UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
Smart Fan
• The internal temperature of the machine is continuously measured.
• The cooling fan speed is increased or decreased according to the measured temperature.
• Fan is stopped completely under 30°C.
• The amount of dust entering the machine is reduced by this function. As the machine life is prolonged, energy
is saved.
• The fan provides continuous cooling performance during welding.
Voltage Protection
• If the mains voltage is above 275 V, the machine automatically protects itself by giving an E03 fault on the
display. By this means, no damage is caused to the machine components and long life of the machine is ensured.
• The same applies for low voltage. If the mains voltage is below 160 V, the machine protects itself by giving an
E02 error.
• After the ambient conditions have returned to normal, the machine functions will also be activated.
Lift TIG
• Lift TIG function allows TIG to be made without damaging the Tungsten tip while rubbing it.
Protection
• Displayed as E03 error.
• Machine functions will be activated when the phases are corrected.
Smart Performance
• Thanks to the intelligent performance control, the welding parameters of the machine are continuously
monitored and analyzed.
• If compulsory conditions occur, the machine switches to the protection mode in order to extend its life and
protect itself against malfunctions.
• This protection is indicated by a thermal led warning on the machine panel.
• The machine is reactivated after 2 minutes of safe time.
Smart Start
• Tungsten provides arc ease in TIG welding by heating the electrode.
Anti Stick
• Anti-Stick feature to prevent the electrode from sticking.
Operation With Generators
• Suitable for operation with generators. The kVA operating value should be determined by referring to the
technical specifications.
VRD Function
• Occupational safety requirements are fulfilled with the VRD function where the
security measures are high.
• It should be ensured that the supply voltage is below 12 Volts when idle.
• The VRD menu is accessed using the current setting pot.
• VRD menu will open by pressing the current setting pot for 3 seconds.
Set the “on/off “ state by turning the current adjustment pot to the left and right.
• When “on” is shown on the digital display, the VRD mode will be on and the VRD led
will be lit, and when “o “ is shown , the VRD mode and the VRD LED will be o .
• If you want to exit the VRD menu, press the current setting pot once to return to the
main menu.
3.2 Machine Features
Operation
Содержание PROSTICK 200i
Страница 1: ...proSTICK 200i 90 444 93 53 magmaweld com info magmaweld com 90 538 927 12 62 USER MANUAL ...
Страница 92: ......
Страница 93: ......
Страница 94: ......
Страница 95: ......