Contact tip and nozzle on the torch have to be cleaned regularly and
changed if required. Contact tips must be in good condition, longer tips
generally give better results.
NOTE:
The above recommended maintenence periods are indicative, these may vary according to the
work shop conditions.
If the Thermal Protection LED
lights up while cooling fan is working and the machine doesn't weld; machine
maybe overheated and stopped for auto protection due to overheat. Hot weather or working in high current
values for long time may cause this. Let the machine on for a while in order to cool down itself with the cooling
fan. After it cools enough, Thermal Protection LED
fades away and the machine can weld.
When the Power LED
is lighting, cooling fan is working but the machine does not weld; turn off the machine
for 1 minute then turn it on again and try to weld. If it still doesn't weld,
(3)
(3)
(2)
contact to your authorized technical
service.
10
Clean the labels on the
machine, replace the worn
out labels.
Repair or replace the worn
out welding cables.
Clean and tighten the weld
terminals.
Check isolation of the
electrode holder,
and their cables.
earth
clamp
Open the covers of the
machine and clean with
dry air.
Strictly follow the instructions contained in safety rules while servicing the
machine.
Before removing any screw on the machine for maintenance, power
supply must be disconnected from the electric lines and enough time
should be allowed for capacitor discharging.