4.2 Trouble Shooting
The following tables contain possible errors to be encountered and their solutions.
Thermal LED on the
front panel has lit up
• The machine’s operation cycle rate may be exceeded. Wait for a while to allow the machine to
cool down. If the failure disappears, try to use lower amperage values.
• The fan may not be working. Inspect the fan for to see if it is functioning properly.
If it is still not working, please contact the authorized service center.
• The air inlet and outlet ducts may be blocked. Clear the air ducts from any blockage.
• The machine operating environment can be extremely hot or airless. Have the
machine placed in an environment where it can work more comfortably.
• Make sure that the machine is connected to power.
• Check that the mains connections are correct.
• Check the mains power supply fuses, mains cable and its plug.
• Check the on / off operating switch.
• If you have made all the checks and if the problem still persists, please contact the authorized
service center.
• Make sure that the machine’s grounding pliers are connected to the workpiece.
• Make sure that the cables are secure and that the connection points are not worn
• Make sure that the parameter and process selection are correct.
• According to the process you have chosen, follow the steps below:
• Check the pole that the electrode must be connected and the current value that must be set on
the machine.
• Check that the gas flow is open, ensuring that the flow is accurate.
• Make sure that the tungsten tip is clean.
• Make sure the durableness of the welding torch.
• If you have made all the checks, if the problem still persists, please contact the authorized
service center.
Machine does not work