EN
www.magmaweld.com
21
USER MANUAL | KULLANIM KILAVUZU
ID 500 M/MW PULSE
PAGE 2
Select the wire types
The wire type to be used must be selected correctly.
Setting Range
•
Fe
•
307
•
CuAl8
•
CuSn
•
309L
•
CrNiER308
•
CrNiER316
•
Al 99.5
•
AlSi 5
•
AlMg 5
•
AlMg 4.5Mn
•
FCW-B
•
FCW-R
a) WIRE TYPE
Select the wire diameter.
The wire diameter to be used must be selected correctly.
Setting Range
•
0.8-1.6 mm
b) WIRE DIAMETER
Gas type will be selected.
The type of gas to be used must be selected correctly.
Setting Range
•
82/18
•
92/8
•
97,5/2,5
•
%100 Ar
•
%100 C02
c) GAS TYPE
Material thickness is selected.
The material thickness to be used must be selected correctly.
Setting Range
•
0.6-20 mm
Example;
While the smart mode is selected, if you select argon gas and wire as SG 0.8, the value 0 will be displayed on the screen since this wire cannot be used
with argon gas. If you see the value of 0 on the screen, in any case something wrong has been selected in the menu such as method / wire type / gas
mismatch.
d) THICKNESS
Operation