26
www.magmaweld.com
USER MANUAL | KULLANIM KILAVUZU
ID 300 M / MW
EN
Fan is not operating
Machine operates noisily
Unstable and / or non-adjustable
welding current
Heater outlet is not operating
• Check the fuse
• Contact the authorized service
• Contact the authorized service
• Check the fuse. Contact the
authorized service
• The fuse has blown
• Contactor failure
• Diode group failure
• The fuse has blown
• Fan motor failure
• Contact the authorized service
Failure
Reason
Solution
The list below contains all the error codes of the welding machines. Consider the error codes related with your machine.
4.4 Error Codes
• Check visually whether the fan is
working or not
• If the problem continues, contact the
authorized service
• Open the front of the air ducts
• If the problem continues, contact the
authorized service
• Fan may not be working
• The front of the air inlet-outlet ducts
may be blocked
• The machine working environment
may be too hot or stuffy
• The uptime of your machine may have
been exceeded
• Make sure that the working
environment of the machine is not
excessively hot or stuffy
• If the problem continues, contact the
authorized service
• Allow the machine to cool down by
waiting for a while. If the fault
disappears, try to use the machine at
lower amperage values
• If the problem continues, contact the
authorized service
E01
E02
Thermal
Protection
(Primary)
• Check the mains connection cables
and the voltage. Make sure the
correct voltage input is provided.
If the mains voltage is normal,
contact the authorized service
• Mains voltage may have decreased
E03
E04
E05
E06
Mains Voltage
Low
• Check the mains connection cables
and the voltage. Make sure the
correct voltage input is provided.
If the mains voltage is normal,
contact the authorized service
• Mains voltage may have increased
Mains Voltage
High
Current / Voltage
Reading Error
Temperature Sensor
Reading Error
Water Cooling
Unit Error
• Contact the authorized service
• Contact the authorized service
• Check water cooling unit connector
and torch inlets/outlets
• Make sure there is water circulation
• If the problem continues, contact the
authorized service
• There may be a hardware error
• There may be a hardware error
• There may be an error in the water
cooling unit
Error Code
Error
Cause
Solution
Maintenance and Service