6
Using the LiftPlus
NOTE:
The LiftPlus must be unfolded and the folding latch locked before the quick change latch is
lifted or lowered. Failure to do so can damage the unit.
Loading the LiftPlus
1. Do not exceed the load capacity of 350 lbs. (120 lbs. on high-speed models).
2. Set the parking brake before loading (see page 10).
3. Be sure the load center of gravity is located as close as possible to the center or rear of the attachment.
Lift/Lower Operation
1. Move the power switch to the On position.
2. To lift the load, pull the lift actuation switch toward the back of the unit.
3. To lower the load, press the lift actuation switch toward the front of the unit.
Lift Overload
1. The overload protection circuit prevents lifting motion when it senses an excessive load. When the
circuit is triggered, a red light illuminates on the back of the LiftPlus.
2. To reset the overload circuit, lower the platform all the way to the bottom. The red light will turn off
when lifting function has been restored.
Circuit Breaker
1. When the circuit breaker trips, the button will pop-up and show a white face.
2.
Reset the circuit breaker by pressing the button down until you hear a click. It will not reset for the first
few seconds after tripping.
3. If the circuit breaker tips repeatedly, contact Magline.
Tripped
Normal