CooLift
®
Area
Description
Method of
Inspection
Normal Condition
Findings
Pass or Fail
T
iming
Notes
Propulsion
System
Electrical
Operate Fwd/Rev
switch several
times
•
Unit should run smoothly in either
direction
•
No rattling or excessive noise
Daily
General
Inspection
W
arning
and branding
labels
are in good condition
V
isual inspection
•
Labels are in place and not coming
loose
•
Labels are in good condition
•
Red stripes are in place and in
good condition
W
eekly
Frame
Frame is in good condition
•
No damage
•
No excessive wear
V
isual inspection
•
Straight sections
•
Smooth curves
•
Flat surfaces
•
Minor scratches and dings are
expected
W
eekly
Frame
Containment strap plate
V
isual inspection
•
Plate should be flat and free of
damage or excessive wear
•
Plating should not be cracked or
damaged
•
Mounting screw should be tight
W
eekly
Deck
Deck is in good condition
•
No damage
•
No excessive wear
V
isual inspection
•
Straight sections
•
Smooth curves
•
Flat surfaces
•
Minor scratches and dings
W
eekly
Deck
Y
oke screws are not loose
in deck
Manual inspection
Screws are tight
W
eekly
Brake System
No system leaks
•
Fittings on master cylinder
,
connecting block & calipers
•
Master cylinder body
•
Caliper body
•
Hoses
Wipe around
fittings and master
cylinder with dry
rag
No leaks (rag remains dry)
W
eekly
Brake System
Brake lever in good
condition and operating
properly
V
isual inspection
Operate brake
•
No visible damage
•
Smooth operation
W
eekly
Brake System
Mounting screws tight
•
Master cylinder mount to
handle
•
Master cylinder cap
•
Connecting block to base
of enclosure
•
Caliper mounting
Manual inspection
•
Parts are tight to mounting surfaces
W
eekly