Installation
MKG Series Gas Griddle
L25-055 Rev. 0 (05/12)
9
regulator, see Figure 6 & 6a. To check the supply pressure to the appliance use the pressure test
point supplied on the manual shut off valve, also see Figure 6 & 6a.
3. Use pipe joint compound that is suitable for use with LP gas on all threaded connections.
4. Turn off all thermostats.
5. Turn on gas supply and check all connections for leaks using ONLY a leak checking fluid or soapy
water. NEVER use an open flame to check for gas leaks.
6. Provisions must be made for adequate air supply for both the appliance and room occupants.
7. Keep area in front of unit clear of obstructions that may block flow of combustion and/or ventilation air.
Figure 6a, Snap Action Regulator System
1.7.2. Gas
Settings
Orifices are sized to provide proper gas flow to the rated BTU/hr for each model. Regulator pressure
must be measured and adjusted before the unit goes into service, following installation and when
operational performance is in question. The manifold and supply pressure readings are taken at the
pressure test points provided, see Figure 6 & 6a.
WARNING
Ensure that the appliance can get enough air to keep the flame burning correctly. If the flame is
starved for air, it can give off a dangerous carbon monoxide gas. Carbon monoxide is a clear odorless
gas that can cause suffocation.
Gas Type
BTU/hr(kW) per Burner
Manifold Pressure (All Models)
Natural
15,000 (4.4)
4.0" WC (10.1cm) [10 mbar]
Propane
15,000 (4.4)
10.0" WC (25.4cm) [25 mbar]