3.10.6. Checking for Spillage
1. Close all doors and windows.
2. Turn the fire on to its full rate and leave it
burning for 5 minutes.
3. Test for spillage using a smoke match (in
a ‘Blume tube’) at the top of the
appliance, fireplace opening or under the
canopy at the centre, with the smoke
match being approximately 25mm under
and 6 - 12mm inside the opening.
4. If the test indicates spillage, repeat the
test after a further 10 minutes
5. If the fire shows tendency to spill, this
may indicate either an installation fault or
a flue construction fault.
Disconnect
the fire and seek expert advice.
The imitation fuels must be laid
in accordance with the
instructions prior to
commencing the spillage test.
If there are any extractor fans in
the nearby rooms then repeat
the smoke match test with all
these fans operating and any
interconnecting doors open
between the fans and the fire.
3.10.7. Instructing the User
The installer must hand over these
instructions to the user and explain how to
operate this fire, stressing the importance of
having the fire checked and serviced
regularly. An annual service is
recommended.
It is mandatory as part of the
gas installation that the installer
instructs the user on the correct
operation and care of their
appliance.