Page 36
3.10. Installation Procedure (Inset Model)
If applicable, carefully unpack the contents of the carton and check them against the checklist
given in
Section 3.8
.
Make sure that the fireplace opening is suitable for the installation of the fire and prepare the
fireplace to suit the dimensional requirements given in
sections 3.2, 3.4
and
3.6
(i.e. fitting the
fire surround, the hearth, etc.).
1. Place the burner centrally within the
fireplace opening and position it as far
back as possible.
2. No part of the burner tray should be
allowed to project beyond the vertical
plane of the fireplace opening.
3. Mark, drill and plug the holes in the front
legs of the fire tray onto the hearth.
4. If fitting a heat shield fold it to shape in
accordance with the instructions supplied
and position the left hand fixing hole on
the heat shield coincident with the hole in
the leg of the tray and mark drill and plug
the three holes (see
Figure 60
).
5. Connect the gas supply to the inlet of the
gas valve via easy fit pipe and the
isolating valve supplied. Route the cable
for the Optimum Control Model if
applicable.
6. Secure the tray (and heat shield) to the
hearth (or Thermobox) with appropriate
screws.
7. For LPG models, the gas bottle must be
fitted with a non-adjustable, low-pressure
regulator with 37mbar (GB) supply.
8. Remove the transit tape.
9. For Manual Control models. Proceed to
Section 3.10.4
. For other control
options, proceed to instructions from
those in
Sections 3.10.1
to
3.10.3
as
applicable.
Heat
Shield
Figure 60
Содержание Premos 16 Inset
Страница 8: ...Page 4 This page is left intentionally blank...
Страница 20: ...Page 16 Large Random Coals Figure 27 Small Random Coals Figure 28...
Страница 39: ...Page 35...