manualshive.com logo in svg
background image

EC DECLARATION OF CONFORMITY

DECLARATION OF CONFORMITY  

According to Annex III A Low Voltage Directive 2014/35/EU +  

Machinery Directive 2006/42/EC 

MAGIC FX B.V. declares as manufacturer and composer of the technical construction file that the 
product with the following specifications: 

Name machine 

: STAGE SHOT II / STADIUM SHOT II / X-TREME SHOT 

Type 

: MFX0410II / MFX0401II / MFX0414 

Voltage 

: 100-250Vac/12-24Vdc 

Max. Working Pressure  : 8 bar / 116 psi 
Volume 

: 17,7L / 36L / 68L 

Serial number 

: on product 

Year of construction 

: on product 

Is in conformity with the minimal safety regulations as stated in the following directive(s): 

 

EMC (2014/30/EC)   ElectroMagnetic Compatibility 

 

RoHS (2011/65/EU)   Restriction of the use of certain Hazardous Substances 

 

WEEE (2012/19/EU)   Waste Electrical & Electronic Equipment 

 

PED  (2014/68/EU)  Pressure Equipment 

The following harmonized standards were applied: 

 

NEN-EN-ISO 12100:2010, Safety of machinery - General principles for design - Risk 
assessment and risk reduction. 

 

NEN-EN-IEC 60204:2010, Safety of machinery - Electrical equipment of machines - Part 1: 
General requirements. 

 

NEN-EN-IEC 61000-6-3:2007/A1:2011, Electromagnetic compatibility (EMC) - Part 6-3: 
Generic standards - Emission standard for residential, commercial and light-industrial 
environments. 

 

NEN-EN 13445-1:2016, Unfired pressure vessels. 

 Original declaration of conformity 

 Translation of the original declaration of conformity 

Name manufacturer 

: MAGIC FX BV 

Address  

: Schouwrooij 27, 5281 RE BOXTEL 

Country 

: The Netherlands 

 
CEO 

: B. Veroude 

Date 

: 6-10-2017 

Signature 

 

Содержание STAGE SHOT II

Страница 1: ...STAGE STADIUM X TREME SHOT USER AND INSTALLATION MANUAL CONFETTI STREAMER FX PART01339 rev 01 02 ENGLISH...

Страница 2: ...anual TRADEMARKS Any brand names mentioned in this manual are registered trademarks of their respective owners LIABILITY MAGIC FX accepts no liability for claims from third parties arising from unauth...

Страница 3: ...UM SHOT II 8 1 4 MAGICFX X TREME SHOT 10 2 Shoot safely 12 2 1 General safety rules 12 2 2 Transport 12 2 3 Compressed air 12 2 4 Rigging 13 2 5 Noise level 13 2 6 Safety symbols 13 2 7 Precautions fo...

Страница 4: ...l result in death or serious injury This signal word is to be limited to the most extreme situations WARNING Indicates a hazardous situation that if not avoided could result in death or serious injury...

Страница 5: ...CFX STADIUM SHOT II is equipped with a 36 litre air pressure tank and is intended for outdoor use The MAGICFX X TREME SHOT is a special effects machine that shoots confetti loads up to 8 kg 30 metres...

Страница 6: ...b Environment Minimum Temperature 10 C 14 F Maximum Temperature 70 C 158 F Humidity Relative 20 to 90 non condensing Electrical Voltage Input Vac 100 250 Vac Voltage Frequency 50 60 Hz Power Consumpti...

Страница 7: ...T II MFX0406II Flexible air hose 5 m II MFX0405 Air Compressor 8 L 8 bar Accessories of the MAGICFX STAGE SHOT II INPUT OUTPUT The output pipe has a capacity of 3 litres and can be filled with confett...

Страница 8: ...lb Environment Minimum Temperature 10 C 14 F Maximum Temperature 70 C 158 F Humidity Relative 20 to 90 non condensing Electrical Voltage Input Vac 100 250 Vac Voltage Frequency 50 60 Hz Power Consump...

Страница 9: ...ories of the MAGICFX STADIUM SHOT II INPUT OUTPUT The output distance depends on the type of input material The maximum load per shot also depends on the type of input material Check the following tab...

Страница 10: ...lb Environment Minimum Temperature 10 C 14 F Maximum Temperature 70 C 158 F Humidity Relative 20 to 90 non condensing Electrical Voltage Input Vac 100 250 Vac Voltage Frequency 50 60 Hz Power Consump...

Страница 11: ...ories of the MAGICFX X TREME SHOT INPUT OUTPUT The output distance depends on the type of input material The maximum load per shot also depends on the type of input material Check the following table...

Страница 12: ...he direct output Make sure that children unauthorised people and animals do not obtain access to the machine Make sure there are no freestanding objects or objects that can be damaged by the machine w...

Страница 13: ...ironmental noise level as measured at the ear is greater than 70 dB A This level of noise is only reached during the short instances that the output is active Always wear hearing protection when you a...

Страница 14: ...ts Not doing so results in death or serious injury X 45 Product Distance X STAGE SHOT II 25 m 85 ft STADIUM SHOT II 40 m 131 ft X TREME SHOT 50 m 165 ft WARNING Always create a safety zone around the...

Страница 15: ...ectrocution WARNING Missing or obscured safety symbols on the machine can lead to death serious injury or property damage Make sure all safety symbols are correctly in place and visible see Section 2...

Страница 16: ...MAGICFX STAGE SHOT II STADIUM SHOT II X TREME SHOT User and Installation Manual 3 LET S SHOOT 3 1 INSTALL THE MACHINE 1 Bring the cased machine to the desired location 2 Unlock and remove the top cov...

Страница 17: ...MAGICFX STAGE SHOT II STADIUM SHOT II X TREME SHOT User and Installation Manual 17 3 Remove the output pipe 4 Pull the locking clamps downwards to unlock and rotate them upwards...

Страница 18: ...STAGE SHOT II STADIUM SHOT II X TREME SHOT User and Installation Manual 5 Place the output pipe in the coupling while holding the locking clamps upwards 6 Lock the output pipe in place with the locki...

Страница 19: ...stallation Manual 19 7 Pull the clamps outwards to check if the locking pins are properly locked in place If not remove the output pipe and repeat step 5 and 6 Never use the machine when the clamps ar...

Страница 20: ...SHOT II STADIUM SHOT II X TREME SHOT User and Installation Manual 9 Set the tank with attached output pipe in an angle between 0 and 90 degrees 10 Turn the tank clamps clockwise to firmly secure the...

Страница 21: ...chine in its final position and set the brakes 12 Take the necessary safety precautions see Section 2 7 3 2 CONNECT POWER 1 Make sure that the power output on your controller or power switch is disabl...

Страница 22: ...wer switch 4 Optionally connect another machine to the power output with a power link cable 100 250 Vac only PowerCon TRUE1 female PowerCon TRUE1 male POWER POWER IN POWER OUT POWER IN POWER OUT CAUTI...

Страница 23: ...ou hear a click sound 3 If desired run a test with pressure Follow the steps from Section 3 5 and 3 6 3 4 FILL WITH CONFETTI AND OR STREAMERS 1 Make sure that the machine is functioning correctly by r...

Страница 24: ...nstallation Manual 4 Fill the output pipe with confetti and or streamers Check Chapter 1 for the maximum amount per approved type of input 5 Place a pressure cap on top of the output pipe 6 Secure the...

Страница 25: ...essor to the air coupling Only use a compressor with a maximum output of 8 bar The end of the hose must be fitted with a quick connect coupling 2 Switch on the air compressor and fill the tank to a ma...

Страница 26: ...S SHOOT 1 Make sure that the prescribed safety zone is free from persons and objects 2 When it s time to shoot switch the power on 3 Enjoy the view 4 Switch the power off 3 7 CLEAN UP 1 Disconnect th...

Страница 27: ...II STADIUM SHOT II X TREME SHOT User and Installation Manual 27 3 Open the ventilation valve to remove any remaining air from the tank TANK PRESSURE 4 Pull the locking clamps downwards to unlock and r...

Страница 28: ...28 MAGICFX STAGE SHOT II STADIUM SHOT II X TREME SHOT User and Installation Manual 5 Remove the output pipe from the coupling 6 Store the output pipe in the flight case...

Страница 29: ...MAGICFX STAGE SHOT II STADIUM SHOT II X TREME SHOT User and Installation Manual 29 7 Place and lock the top cover 8 Release the brakes...

Страница 30: ...d electrical and electronic products should not be mixed with general household waste For proper treatment recovery and recycling please take this product to designated collection points where it will...

Страница 31: ...S 2011 65 EU Restriction of the use of certain Hazardous Substances WEEE 2012 19 EU Waste Electrical Electronic Equipment PED 2014 68 EU Pressure Equipment The following harmonized standards were appl...

Страница 32: ...WWW MAGICFX EU...

Отзывы: