Страница 1: ...STADIUMSHOT III USER AND INSTALLATION MANUAL CONFETTI STREAMER FX PART01839 rev 01 02 ENGLISH...

Страница 2: ...red trademarks of their respective owners LIABILITY MAGIC FX accepts no liability for claims from third parties arising from unauthorised use use other than that stated in this manual and use other th...

Страница 3: ...eral safety rules 14 2 2 Transport 14 2 3 Compressed air 15 2 4 Outdoor use 15 2 5 Rigging 15 2 6 Noise level 15 2 7 Confetti streamers 15 2 8 Safety symbols 16 2 9 Precautions for operation 16 3 Inst...

Страница 4: ...eath or serious injury CAUTION Indicates a hazardous situation that if not avoided could result in minor or moderate injury NOTICE Indicates information considered important but not hazard related e g...

Страница 5: ...RDM Remote Device Management ARM SYSTEM MAGICFX SFX SAFETY ARM SYSTEM ARM CONTROLLER MAGICFX SFX SAFETY ARM CONTROLLER E STOP MAGICFX SFX SAFETY E STOP TERMINATOR MAGICFX SFX SAFETY TERMINATOR STADIU...

Страница 6: ...display to accommodate different venues When the machine is loaded with MAGICFX CONFETTI or STREAMERS a single push on the physical button on the STADIUMSHOT III will charge the air tank to the set p...

Страница 7: ...OR ON OFF BUTTON INDEX PLUNGER TOP COVER OUTPUT PIPE STRAP PLATE REMOVABLE HANDLE WITH AIRFILTER BRAKE COUPLING WITH LOCKING CLAMPS PRESSURE GAUGE DMX INPUT OUTPUT 5 POLE FX WARNING LED POWER INPUT OU...

Страница 8: ...sing Electrical Voltage Input Vac 100 250 Vac Voltage Frequency 50 60 Hz Power Consumption Vac 350 W Power Connector Vac Neutrik powerCON TRUE1 in out Controlling Control Options DMX 24 Vdc Control Pr...

Страница 9: ...D HHHHHHHHHHHH Bootloader CRC Serial Number DDDDD Build Date Uptime DDDD HH MM SS E ect Time DDDD HH MM SS Status Display DMX Start Address 1 512 DMX Enable Address 1 512 DMX Footpr DMX Enable DMX inp...

Страница 10: ...N cables that carry the safety signal from the ARM CONTROLLER For more information about the ARM SYSTEM and to learn how to configure a complete safety system refer to the ARM SYSTEM Configuration Man...

Страница 11: ...ase there is a locking error present this button will reset the appliance If the fault does not persist the locking error will not reappear DMX Start Address 1 512 Setting the DMX start address DMX En...

Страница 12: ...oftware CRC CRC of the functional software Bootloader CRC CRC of the bootloader software Build Date Release date of functional software Up Time DDDD HH MM SS Time counter which indicates how long the...

Страница 13: ...PART01882 1 9 INPUT OUTPUT The output pipe has a payload of 5 litres and can be filled with MAGICFX confetti or streamers The maximum load per shot depends on the type of input material The output dis...

Страница 14: ...have been made other than by or on behalf of MAGICFX Make sure that children unauthorised people and animals do not obtain access to the STADIUMSHOT III Make sure there are no freestanding objects or...

Страница 15: ...on valve 2 4 OUTDOOR USE The STADIUMSHOT III is designed for outdoor use WARNING The STADIUMSHOT III can be used indoors in large event halls and arenas Please refer to page 17 2 5 RIGGING Please foll...

Страница 16: ...rious injury or property damage Never leave the machine and the power switch unattended when the machine is ready for use WARNING Do not use the STADIUMSHOT III if alterations have been made other tha...

Страница 17: ...as shown in the image below clear of all people animals and objects Not doing so results in death or serious injury WARNING Always create a safety zone around the machine with a radius of 5 meters 16...

Страница 18: ...CFX STADIUMSHOT III User and Installation Manual 3 INSTALLATION AND USE 3 1 INSTALL THE MACHINE 1 Bring the cased machine to the desired location 2 Place the machine in its final position and set the...

Страница 19: ...machine to fixate the machine and prevent it from moving WARNING Always make sure to properly fixate the machine on a stable and suited surface Not doing so can result in death or serious injury NOTIC...

Страница 20: ...20 MAGICFX STADIUMSHOT III User and Installation Manual 5 Remove the output pipe 6 Pull the locking clamps downwards to unlock and rotate them upwards...

Страница 21: ...ards 8 Lock the output pipe in place with the locking clamps 9 Pull the clamps outwards to check if the locking pins are properly locked in place If not remove the output pipe and repeat step 5 and 6...

Страница 22: ...the tank in the desired position Make sure the index plunger is properly in place WARNING Never use the machine when the index plunger is not properly in place or working properly Not doing so can re...

Страница 23: ...CONTROLLER the STADIUMSHOT III the control equipment and other ARM SYSTEM components and machines if applicable Check the following variants for connection details A The STADIUMSHOT III is controlled...

Страница 24: ...hen enabling the ARM CONTROLLER Pressure safety checks will not work and it is possible to shoot confetti and streamers at an unsafe pressure See Section 1 8 CAUTION Do not connect more units to a sin...

Страница 25: ...nd the gauge pressure is 0 bar Not doing so can result in death or serious injury 1 Place a lifting core in the bottom of the output pipe Make sure the lifting core lies flat and closes off the hole i...

Страница 26: ...g so will result in death or serious injury DANGER Always make sure unauthorized persons animals or objects are not able to get in front of the shooting direction Not doing so will result in death or...

Страница 27: ...for the desired quick connector 4 Close the top cover see Section 4 1 5 Connect the hose from an external air source to the quick coupling Only use an air source with an air filter with a maximum outp...

Страница 28: ...w 5 Deactivate the external low voltage pyro controller 24V 6 Set the safety key in the OFF position to disarm the ARM SYSTEM and disable operation of the STADIUMSHOT III and other connected SFX machi...

Страница 29: ...is ready to be used again 3 7 CLEAN UP 1 Open the vent valve to release the pressure and make sure the gauge pressure is 0 bar 2 Disconnect the cables 3 Rotate the tank to the vertical 0 position 4 P...

Страница 30: ...30 MAGICFX STADIUMSHOT III User and Installation Manual 5 Remove the output pipe from the coupling...

Страница 31: ...MAGICFX STADIUMSHOT III User and Installation Manual 31 6 Store the output pipe in the flightcase 7 Remove the lashing ratchet...

Страница 32: ...32 MAGICFX STADIUMSHOT III User and Installation Manual 8 Place and lock the flightcase cover 9 Release the brakes...

Страница 33: ...cooling fins and motor housing Contact MAGIC FX if the machine is not functioning correctly DANGER Do not replace parts yourself other than specified in this chapter always consult MAGIC FX DANGER Nev...

Страница 34: ...ng an air in filter The compressor may be seriously damaged NOTICE Replace the air in filter element periodically The replacement frequency depends on operating frequency and operating environment For...

Страница 35: ...using from the machine by rotating clockwise 3 Open the plastic housing of the air in filter 4 Replace the air in filter 5 Close the plastic housing of the air in filter 6 Screw the air in filter hous...

Страница 36: ...the vent valve is entirely closed Press the compressor on off button to pressurize again If the problem is not solved contact MAGIC FX Troubleshooting Always contact MAGIC FX if any malfunctions or e...

Страница 37: ...oHS 2011 65 EU Restriction of the use of certain Hazardous Substances WEEE 2012 19 EU Waste Electrical Electronic Equipment PED 2014 68 EU Pressure Equipment The following harmonized standards were ap...