background image

MAGICFX

®

 STADIUMBLASTER 

 

User and Installation Manual

    27

Disconnect the CO

2

 hose from the 

CO

2

 Bottle to Hose Connector on 

the CO

2

 cylinder.

Remove the CO

2

 Bottle to Hose 

Connector from the cylinder.

7

 

Connect a CO

2

 Bottle to Hose 

Connector to a new CO

2

 cylinder.

Содержание STADIUMBLASTER MFX0803

Страница 1: ...STADIUM BLASTER CONFETTI STREAMER FX PART01104 rev 01 01 USER AND INSTALLATION MANUAL ENGLISH...

Страница 2: ...KS Any brand names mentioned in this manual are registered trademarks of their respective owners LIABILITY MAGIC FX accepts no liability for claims from third parties arising from unauthorised use use...

Страница 3: ...1 General safety rules 11 2 2 CO2 11 2 3 Indoor use 12 2 4 Rigging 12 2 5 Noise level 12 2 6 Safety symbols 13 2 7 Precautions for operation 13 3 Let s blast 14 3 1 Install the machine 14 3 2 Fill wit...

Страница 4: ...not avoided will result in death or serious injury This signal word is to be limited to the most extreme situations WARNING Indicates a hazardous situation that if not avoided could result in death or...

Страница 5: ...ti continuously from the hopper out of the woofer and into the air The effect is accompanied by a strong hissing sound If liquid CO2 is applied a white plume of smoke will be visible The MAGICFX STADI...

Страница 6: ...Input Vac 100 250 Vac Voltage Frequency 50 60 Hz Power Consumption Vac 20 W Power Connector Vac Neutrik powerCON TRUE1 in out Voltage Input Vdc 18 36 Vdc Power Consumption Vdc 17 W Power Connector Vdc...

Страница 7: ...rees MFX0313 Schuko to Neutrik powerCON TRUE1 cable 1 5 m X Accessories 1 5 CONFETTI The MAGICFX STADIUMBLASTER can be set in 5 different angles between 45 and 90 The output height and output distance...

Страница 8: ...ults in the following DMX Address DMX Value decimal Result Safety 0 99 Device disabled 100 155 Device enabled 156 255 Device disabled Start output 0 199 Valve closed 200 255 Valve open Operation of th...

Страница 9: ...usly lights red when an error is present Idle Display Main Menu DMX Start Address 1 512 DMX Safety Address 1 512 DMX Footprint Fixed Unique ID Bootloader CRC Serial Number Build Date Lock Unlock Contr...

Страница 10: ...upported by the MAGICFX STADIUMBLASTER Parameter ID Discovery GET SET DISC_UNIQUE_BRANCH X DISC_MUTE X DISC_UN_MUTE X DEVICE_INFO X SUPPORTED_PARAMETERS X SOFTWARE_VERSION_LABEL X DEVICE_MODEL_DESCRIP...

Страница 11: ...ect output Make sure that children unauthorised people and animals do not obtain access to the MAGICFX STADIUMBLASTER Make sure there are no freestanding objects or objects that can be damaged by the...

Страница 12: ...O2 could accumulate and taking preventive actions Installing CO2 monitoring devices that will warn for hazardous CO2 levels DANGER Do not use the MAGICFX STADIUMBLASTER in poorly ventilated confined s...

Страница 13: ...mbols on the machine can lead to death serious injury or property damage Make sure all safety symbols are correctly in place and visible see Section 2 6 CAUTION A missing or loose fitted woofer can le...

Страница 14: ...14 MAGICFX STADIUMBLASTER User and Installation Manual 3 LET S BLAST 3 1 INSTALL THE MACHINE 1 Bring the cased MAGICFX STADIUMBLASTER to the desired location 2 Unlock and remove the top cover...

Страница 15: ...MAGICFX STADIUMBLASTER User and Installation Manual 15 3 Unlock and remove the cover from the bottom cabinet 4 Take out the woofer...

Страница 16: ...16 MAGICFX STADIUMBLASTER User and Installation Manual 5 Screw the woofer firmly onto the bayonet socket of the hopper until it locks in place 6 Secure the woofer with the safety steel...

Страница 17: ...ation Manual 17 7 Optionally you can set the hopper with the attached woofer in one of the 5 pre set angles 8 Place the MAGICFX STADIUMBLASTER in its final position and set the brakes 9 Take the neces...

Страница 18: ...18 MAGICFX STADIUMBLASTER User and Installation Manual 10 Make sure the manual CO2 valve is in CLOSED position 11 Connect the CO2 hose to the CO2 quick connector...

Страница 19: ...on Manual 19 12 Connect a CO Bottle to Hose Connector to a CO2 cylinder 13 Connect the CO2 hose to the CO Bottle to Hose Connector on the CO2 cylinder 14 Open the CO2 cylinder 15 In case of multiple m...

Страница 20: ...IUMBLASTER User and Installation Manual 3 2 FILL WITH CONFETTI BEFORE EACH BLAST 1 Unlock and open the lid of the hopper 2 Fill the hopper with confetti Check Section 1 5 for the maximum amount per ty...

Страница 21: ...3 3 BLAST MANUALLY 1 Make sure that the safety zone is free from persons and hazardous objects 2 When it s time to blast move the manual CO2 valve in OPEN position NOTICE The best effect results are...

Страница 22: ...22 MAGICFX STADIUMBLASTER User and Installation Manual 3 Enjoy the view 4 When the hopper is out of confetti move the manual CO2 valve back in CLOSED position...

Страница 23: ...ive when control is applied The controller only powers the output valve 3 5 BLAST WITH 24 V CONTROL 1 Make sure that the safety zone is free from persons and hazardous objects 2 When it s time to blas...

Страница 24: ...the power input 2 Connect the other end of the power cable to a 100 250 Vac 50 60 Hz power source 3 Connect the female connector of a 5 pole DMX cable in the DMX input 4 Connect the other end of the...

Страница 25: ...ses see chapter 1 6 Repeat step 1 to 5 for each subsequent machine CAUTION Always plug in a DMX Terminator into the DMX output of the final unit in the control sequence Using a DMX Terminator improves...

Страница 26: ...l CO2 valve is in CLOSED position b The DMX Safety address is not activated FX LED indicator is dimmed c The 24 V controller if used is not powered 2 Close the CO2 cylinder 3 Move the manual CO2 valve...

Страница 27: ...Installation Manual 27 5 Disconnect the CO2 hose from the CO2 Bottle to Hose Connector on the CO2 cylinder 6 Remove the CO2 Bottle to Hose Connector from the cylinder 7 Connect a CO2 Bottle to Hose C...

Страница 28: ...ottle to Hose Connector on the new CO2 cylinder 9 Open the CO2 cylinder 10 In case of multiple machines Repeat steps 1 9 for each machine 3 10 CLEAN UP 1 Deactivate the Safety address FX LED indicator...

Страница 29: ...ation Manual 29 4 Move the manual CO2 valve in OPEN position to release the pressure from the system 5 Disconnect the CO2 hose from the CO2 quick connector 6 Disconnect the CO2 hose from the CO2 Bottl...

Страница 30: ...stallation Manual 7 Remove the CO2 Bottle to Hose Connector from the cylinder 8 Wait until the ice crust on the output has melted 9 In case you have set the hopper under an angle Position the hopper b...

Страница 31: ...MAGICFX STADIUMBLASTER User and Installation Manual 31 10 Remove the safety steel 11 Remove the woofer...

Страница 32: ...32 MAGICFX STADIUMBLASTER User and Installation Manual 12 Remove the woofer 13 Place and lock the cover of the bottom cabinet 14 Unlock and open the lid from the hopper...

Страница 33: ...MAGICFX STADIUMBLASTER User and Installation Manual 33 15 Remove remaining confetti from the hopper 16 Close and lock the lid from the hopper 17 Place and lock the top cover 18 Release the brakes...

Страница 34: ...that used electrical and electronic products should not be mixed with general household waste For proper treatment recovery and recycling please take this product to designated collection points wher...

Страница 35: ...atibility RoHS 2011 65 EU Restriction of the use of certain Hazardous Substances WEEE 2012 19 EU Waste Electrical Electronic Equipment The following harmonized standards were applied NEN EN ISO 12100...

Страница 36: ...WWW MAGICFX EU...

Отзывы: