SNOW SAFELY!

The MAGICFX

®

 SNOWCASE has been designed and constructed in such a manner 

that it can be used safely. This applies to the use, the circumstances and the 
regulations as described in this documentation. Reading this documentation and 
following the instructions are therefore necessary for everyone who is authorised to 
work with the MAGICFX

®

 SNOWCASE.

The MAGICFX

®

 SNOWCASE must be used in surroundings that:

•  Have a stable temperature of between 0 and 50 °C.
•  Have a relative humidity degree between 20 % and 90 % (non condensing).
•  Are free of dust, corrosive gases and high concentrations of organic vapours.
•  Are not situated in the vicinity of a source of vibration.

2.1 

GENERAL SAFETY RULES

•  Only authorised persons may carry out work with the MAGICFX

®

 SNOWCASE.

•  Do not use the MAGICFX

®

 SNOWCASE if there are people or animals in the 

direct output.

•  Make sure there are no objects in the direct output that can be damaged by 

the MAGICFX

®

 SNOWCASE (e.g. by getting wet).

•  Make sure that children, unauthorised people and animals do not obtain 

access to the MAGICFX

®

 SNOWCASE.

•  Do not connect more units to a single electrical circuit than the installed fuse 

is able to handle. (Calculate the summed load with the electrical data from 
Chapter 1)

•  Do not remove any safeguards, safety caps and safety symbols.
•  All required safety devices must be in good condition and function properly.
• 

Ensure sufficient lighting of the surroundings.

•  Keep the workplace clean.

2.2 

INDOOR USE

The MAGICFX

®

 SNOWCASE is designed for outdoor use and use in well-ventilated 

indoor spaces. 

WARNING

Do not use the MAGICFX

®

 SNOWCASE in poorly ventilated 

confined spaces. Exposure to high levels of MAGICFX

® 

SNOWCASE 

- SNOW FLUID can cause skin and airway irritation.

2.3 

RIGGING

Please follow the European and national guidelines for safe rigging and trussing.

MAGICFX_SNOWCASE_UM-IM_EN_v01-00_A5.indd   14

14-10-2019   08:11:23

Содержание SNOWCASE Series

Страница 1: ...SNOWCASE SNOW FX PART01729 rev 01 00 USER AND INSTALLATION MANUAL ENGLISH...

Страница 2: ...Any brand names mentioned in this manual are registered trademarks of their respective owners LIABILITY MAGIC FX accepts no liability for claims from third parties arising from unauthorised use use ot...

Страница 3: ...Snow safely 13 2 1 General safety rules 13 2 2 Indoor use 13 2 3 Rigging 13 2 4 Noise level 14 2 5 Safety symbols 14 2 6 Precautions for operation 14 3 Let s snow 16 3 1 Install the machine 16 3 2 Re...

Страница 4: ...us situation that if not avoided will result in death or serious injury This signal word is to be limited to the most extreme situations WARNING Indicates a hazardous situation that if not avoided cou...

Страница 5: ...creates the snow effect The MAGICFX SNOWCASE is a very flexible machine It can be operated with the effect coming straight from the machine itself or an extension hose can be connected This gives the...

Страница 6: ...and Installation Manual 1 1 MAIN PARTS SNOW CABINET LID SNOW HEAD CONE MESH ANGLE PIN FLIGHTCASE DISPLAY WITH BUTTONS AND LED INDICATORS FX LED INDICATOR DMX INPUT OUTPUT 5 POLE POWER INPUT OUTPUT 22...

Страница 7: ...Humidity Relative 20 to 90 non condensing Electrical Voltage Input 210 240 Vac Voltage Frequency 50 60 Hz Power Consumption 1150 W Power Connector Neutrik powerCON TRUE1 in out Controlling Control Op...

Страница 8: ...l the machine without the need for DMX and an external lighting console A simple sequence of effect on and off times and desired distance and density can be set via the manual mode menu on the display...

Страница 9: ...dresses When you link multiple machines with DMX we advise you to use the same Safety address for all machines CAUTION Always plug in a DMX Terminator into the DMX output of the final unit in the cont...

Страница 10: ...er Reset Errors DMX RDM Settings continues on next page Con guration RDM ON OFF Run Timer 0 600 s Output Density 0 255 Manual Mode ON OFF Manual Operation Pause Timer 0 600 s Output Distance 0 255 Fac...

Страница 11: ...ress DMX Safety Address 1 512 Setting the DMX safety address DMX Footprint This parameter indicates the DMX footprint in other words the amount of sequential channels used by the appliance This does n...

Страница 12: ...nt of snow fluid used since the cycle was reset Cycle Avg l min Indicates the average snow fluid consumption since the cycle was reset Cycle Reset Yes No When set to Yes this resets the cycle numbers...

Страница 13: ...X DISC_MUTE X DISC_UN_MUTE X DEVICE_INFO X SUPPORTED_PARAMETERS X SOFTWARE_VERSION_LABEL X DEVICE_MODEL_DESCRIPTION X MANUFACTURER_LABEL X SLOT_DESCRIPTION X SENSOR_DEFINTION X SENSOR_VALUE X DMX_STAR...

Страница 14: ...CFX SNOWCASE if there are people or animals in the direct output Make sure there are no objects in the direct output that can be damaged by the MAGICFX SNOWCASE e g by getting wet Make sure that child...

Страница 15: ...yourself or to others for a long period of time If you experience any hearing loss or ringing in the ears you should immediately stop using the unit 2 5 SAFETY SYMBOLS Symbol Meaning Position Read th...

Страница 16: ...ffective output CAUTION Do not tip over the machine This can damage the machine CAUTION Remove the snow fluid jerrycan when transporting the MAGICFX SNOWCASE The jerrycan can tip over and spill fluid...

Страница 17: ...MAGICFX SNOWCASE User and Installation Manual 17 3 LET S SNOW 3 1 INSTALL THE MACHINE 1 Bring the MAGICFX SNOWCASE to the desired location 2 Unlock and remove the top cover...

Страница 18: ...AGICFX SNOWCASE in its final position and set the brakes 3 2 RE PLACE THE JERRYCAN WITH SNOW FLUID WARNING Always follow the instructions as noted on the jerrycans 1 Make sure that the machine is not...

Страница 19: ...MAGICFX SNOWCASE User and Installation Manual 19 3 Place a jerrycan with snow fluid in the snow cabinet and remove and save the lid 4 Connect the snow lid inside the cabinet...

Страница 20: ...Installation Manual 5 Close the snow cabinet lid 6 Pull the angle pin to adjust the angle of the snow head 7 Let go of the angle pin when satisfied with the angle 8 In case of multiple machines Repea...

Страница 21: ...User and Installation Manual 21 3 3 MOUNT THE TRUSS BRACKET AND HOSE 1 Make sure that the machine is not in operation FX LED indicator is dimmed 2 Disconnect the snow head 3 Connect the hose to the M...

Страница 22: ...22 MAGICFX SNOWCASE User and Installation Manual 4 Connect the other end of the hose to the truss bracket 5 Attach the snow head to the other end of the truss bracket...

Страница 23: ...eye located on the top of the snow head 7 Inspect the machine and remove any foreign objects and material that will block or obscure the output nozzle or the air inlets of the machine during operatio...

Страница 24: ...tput in Manual mode see Chapter 1 3 Make sure that Manual mode is ON 4 Please note that the manual mode settings will be retained even after turning off and on again This includes Manual mode OFF ON 3...

Страница 25: ...female connector of a 5 pole DMX cable in the DMX input 4 Connect the other end of the DMX cable to your DMX controller 5 Power up the machine If Manual mode is ON the machine starts snowing instantly...

Страница 26: ...f the next machine 3 Connect a DMX cable to the DMX output 4 Connect the other end to the DMX input of the next machine 5 Power up the machine If Manual mode is ON the machine starts snowing instantly...

Страница 27: ...y the effect reach and density during the effect duration if desired 6 Enjoy the view 7 To deactivate change the DMX value of the effect density to a value below 10 then deactivate the safety adress T...

Страница 28: ...l 2 Open the snow cabinet lid 3 Disconnect the snow lid from the jerrycan First place lid then remove the jerrycan with snow fluid and close off with the original lid 4 Disconnect all DMX and power ca...

Страница 29: ...6 Wipe down the machine with hand warm water and a cloth 7 Clean the floor in front of the machine 8 Place and lock the top cover Make sure the nozzle is in the most horizontal position before placin...

Страница 30: ...lectrical and electronic products should not be mixed with general household waste For proper treatment recovery and recycling please take this product to designated collection points where it will be...

Страница 31: ...of certain Hazardous Substances WEEE 2012 19 EU Waste Electrical Electronic Equipment REACH 1907 2006 Registration Evaluation Authorisation and Restriction of Chemicals The following harmonized stand...

Страница 32: ...WWW MAGICFX EU...

Отзывы: