Programming menu No. 1
When the door is open and ignition is on keep buttons
I
and
II
pressed simultaneously for
2 sec.
No.
Function
Options
Button I
Button II
Button III
Button IV
1-04
Emergency code RPS
Off
On
-
-
1-06
Flashing when the doors
are open
Off
On
-
-
1-08
Flashing when the trunk
is open
Off
On
-
-
1-10
PIN code
Off
On
-
-
1-11
Start kill/IG kill
IG kill
Start kill
-
-
1-12
Dome light delay
Off
5 sec
15 sec
50 sec
1-14
CAN mode
Read only
Read and Write
Read, Write and
close windows
-
1-15
Open the Trunk
with unlock
and disarm
without unlock
and without
disarm
-
-
Functions description:
1-04
When on, you can enter a 4-digit emergency code to cancel the alarm and open the
car.
1-06
When on, alarm will warn of the door opened by flashing the lights.
1-08
When on, alarm will warn that the hood is open by flashing the lights.
1-10
It allows you to enter the valet mode in two ways:
- simple access
– by turning ignition on/off 3 times in row
- secure access
– by turning ignition on/off 3 times in row and entering a 2-digit PIN code by
the button on the back side of RPS.
1-11
In case of using the
IG kill
function, the blocking output is
– active (on -250mA) when
armed, - inactive during a remote starting and disarmed; in case of using the PANIC function
when disarmed, the output will be activated after 30 sec. In case of using the S
tart kill
function,
blocking output is
– active when armed and remotely started, - inactive when disarmed; in
case of using the PANIC function when disarmed, the output will be activated immediately.
1-12
It is possible to set up a delayed reaction to opened door contacts when turning on the
alarm. The function is supposed to be used with indirect closed doors scanning (from the roof
light, etc.)
1-14
This function is available with CAN BUS Magicar module. In case of using the
Read only
function, Magicar only read CAN information (open door, trunk, hood, lock/unlock with OEM
remote, etc.)
In case of using the
Read and Write
function, Magicar can also control lock/unlock, lights and
klaxon except closing windows.
In case of using the
Read, Write and close windows
, Magicar can also close windows when
armed.*
1-15
When option No.1 is chosen, after pressing button
III
system unlock the door, disarming
and open the trunk. When option No.2 is chosen, after pressing button
III
system only open
the trunk, not unlock the door and not disarming. Trunk input will be able trigger system when
trunk is closed.
*See possible function Module CAN BUS Magicar in Table of functions depending on car type.
Содержание M881A
Страница 2: ...Slovensky Strana 3 esky Strana 17 English Page 31 Magyarorsz g Oldal 45 SK CZ EN H...
Страница 16: ...MAGICAR M881A Autoalarm s integrovan m pagerem Mont n manu l...
Страница 30: ...MAGICAR M881A Car alarm with two way remote Installation guide...
Страница 44: ...MAGICAR M881A K tir ny t vvez rl rendszerrel ell tott riaszt Beszerel si tmutat...
Страница 58: ......
Страница 59: ...59...
Страница 60: ...60...