35
EN
EN
EN
EN
Programming menu No. 1
When the door is open and ignition is on keep buttons I and II pressed simultaneously
for 2 sec.
Options
No.
Function
Button I
Button II
Button III
Button IV
1-04
Emergency code RPS
Off
On
-
-
1-06
Flashing when the doors
are open
Off
On
-
-
1-08
Flashing when the trunk
is open
Off
On
-
-
1-10
PIN code
Off
On
-
-
1-11
Start kill/IG kill
IG kill
Start kill
-
-
1-12
Dome light delay
Off
5 sec
15 sec
50 sec
Functions description:
1-04 When on, you can enter a 4-digit emergency code to cancel the alarm and open the
car.
1-06 When on, alarm will warn of the door opened by flashing the lights.
1-08 When on, alarm will warn that the hood is open by flashing the lights.
1-10 It allows you to enter the valet mode in two ways:
- simple access – by turning ignition on/off 3 times in row
- secure access – by turning ignition on/off 3 times in row and entering a 2-digit PIN code
by the button on the back side of RPS.
1-11 In case of using the IG kill function, the blocking output is– active (on -250mA)
when armed, - inactive during a remote starting and disarmed; in case of using the PANIC
function when disarmed, the output will be activated after 30 sec. In case of using the Start
kill function, blocking output is – active when armed and remotely started, -inactive when
disarmed; in case of using the PANIC function when disarmed, the output will be activated
immediately.
1-12 It is possible to set up a delayed reaction to opened door contacts when turning on
the alarm. The function is supposed to be used with indirect closed doors scanning (from
the roof light, etc.)
Programming menu No.2
When the doors are opened and ignition is on, keep the buttons I and IV pressed for 2
sec.
Options
No.
Functions
Button I
Button II
Button III
Button IV
2-01
Trunk output time
0.5 sec
2 sec
3 sec
4 sec
2-02
Door lock impulse
0.8 sec
4 sec
2 x 0.8 sec
15 sec
2-03
Door unlock impulse
0.8 sec
4 sec
2 x 0.8 sec
-
2-06
Parking light
Normal
Continuous mode
Pulse mode
-
2-08
AUX 1
0.5 sec
5 sec
40 sec
Latch
2-09
AUX 2
0.5 sec
5 sec
40 sec
Latch
2-11
Shock sensor on/off
during AUX output
On
Off
-
-
Functions description:
2-01 Impulse time set-up for trunk output.
2-02 Impulse time set-up for door lock.
2-03 Impulse time set-up for door unlock.
2-06 Using this function, you can set the lights control by the alarm mode.
- normal – mainly for direct control of hazard lights by (-) or (+).
- 1-2 mode – designed to control hazard lights by the button (see page 36).