MAGIC FX MFX1201 Скачать руководство пользователя страница 9

Version 1.0 

Page 8

6.

SAFETY

6.1 

INTRODUCTION

The Stage Flame is designed and constructed so that it can be used in a safe manner. Specifically, 
this refers to the usage, situations, and prescriptions for the device as described in this 
documentation. It is the responsibility of all persons authorized to use the Stage Flame to read and 
follow the instructions in this manual. 

The Stage Flame should be located and used in an environment that preferably: 

-

Has a fairly constant temperature between 0 and 30ºC.

-

Has a relative humidity not exceeding a maximum of 75%.

-

Is reasonably free of dust, corrosive gases, and high concentrations of organic vapors.

-

Does not contain any source of vibrations in the environment.

6.2 

GENERAL SAFETY RULES 

-

The Stage Flame should only be used when there are no
people, animals, or inflammable objects within the danger
zone. The danger zone is the cylindrical space around the
device with a radius of three meters. See also the red
shading in Figure 3 (not drawn to scale).

-

Ensure that the Stage Flame is not accessible to children,
unauthorized persons, or animals!

-

Do not touch the Stage Flame when it is operational or
turned on. Even if the device is not in operation it might be
ready to activate.

-

Safety devices must not be removed or rendered
inoperative.

-

All required safety devices should be in good working
order and functioning properly.

-

Ensure that there is adequate lighting in the environment.

-

Keep the workplace clean.

-

Only authorized persons may work with the Stage Flame.

-

It not permitted to use the Stage Flame in an environment containing flammable gases or fluids.

-

Always ask the fire brigade for permission to use the Stage Flame at the desired location.

6.3 

EMERGENCY STOP BUTTON 

The Stage Flame is equipped with an emergency stop button (MFX1201) in case of emergencies. The 
Emergency Stop Button has the following characteristics: 

-

The emergency button is easy to recognize because of its red/yellow colors and should be
positioned so that it can be reached easily and quickly.

-

Pressing the emergency stop button immediately stops the Stage Flame. The emergency stop
button remains mechanically blocked and the device cannot be restarted.

In the event of personal injury, immediate assistance can be given straight away. Any other 
emergency procedures should also be carried out as soon as possible. 
The Stage Flame can be reset after the danger is entirely eliminated. 

The emergency stop button also can be used if there is a sudden danger such as a malfunction. Such 
a situation does not require urgent action. The device can be simply turned off. 
Further safety measures may be required depending on the nature of how the device will be used. 
See the relevant prescriptions. 

Recommendations: 

-

Have new operators practice several times with the emergency stop button.

-

Do not use the emergency stop button to stop the device in normal circumstances.

-

Regularly test that it is working properly.

-

An emergency stop button should not be reset when it is not known who or why it was used.

Содержание MFX1201

Страница 1: ...PRODUCT CODE MFX1201 VERSION 1 0 DATE 18 10 2017...

Страница 2: ...and reliability All products are manufactured in accordance with the European Machinery Directive MAGIC FX handles the entire production in house from concept to finished product We take care of the...

Страница 3: ...purposes or situations than specified in this documentation Modifications to the Stage Flame This includes the use of non original spare parts Improper maintenance Unauthorized removal of safety cover...

Страница 4: ...ponsibility We are the manufacturer of the product MFX1201 MAGICFX Stage Flame to which this declaration pertains and it is in conformity with the provisions of the following guidelines Machinery Dire...

Страница 5: ...ttachments in a secure central location and keep another copy of this manual close to the workplace where the Stage Flame will be used If you are well acquainted with the proper handling of the equipm...

Страница 6: ...ECESSARY ACCESSORIES 6 5 3 TYPES OF GAS 6 5 4 CHOICE OF FLAME 7 6 SAFETY 8 6 1 INTRODUCTION 8 6 2 GENERAL SAFETY RULES 8 6 3 EMERGENCY STOP BUTTON 8 6 4 WARNINGS 9 6 5 FEATURES 10 7 PARTS 11 8 ACCESSO...

Страница 7: ...e mode where both aerosol can and gas bottle are used at the same time The Stage Flame is DMX controllable One address is used as a safety channel and one address for the flame A third address is used...

Страница 8: ...ROSOL CAN GAS BOTTLE Flame height approximately six meters high MODE FLAME HEIGHT MINIMUM CLEARANCE HEIGHT AEROSOL CAN 3M 6M GAS BOTTLE 4M 7M BIG FLAME AEROSOL CAN GAS BOTTLE 6M 10M Table 5 3 DANGER W...

Страница 9: ...in the environment Keep the workplace clean Only authorized persons may work with the Stage Flame It not permitted to use the Stage Flame in an environment containing flammable gases or fluids Always...

Страница 10: ...t ensure that the text is always visible and legible and that it remains so DANGER WARNING Any missing spoilt or illegible text or icons must be replaced The icons used are shown below Icons Explanati...

Страница 11: ...op of the Stage Flame 6 5 FEATURES The Stage Flame has many safety features One of these features checks whether the Stage Flame is moved tilted or is exposed to shocks In these cases the Stage Flame...

Страница 12: ...n 2 Power input 3 Power output 4 DMX input 5 DMX output 6 Gas bottle input 7 Display 8 DMX Led 9 MENU button 10 UP button 11 DOWN button 12 RESET button 13 Warning LEDs 14 Cover fasteners 15 Aerosol c...

Страница 13: ...REPARATION FOR USE Unpack the Stage Flame Dispose of packaging material without causing harm to the environment Check the device for any possible damage You must report any damage to the device to MAG...

Страница 14: ...multiple Stage Flames together using 3 pole DMX cables 3 Ensure the Power button is set to off Connect the power cable The Stage Flame runs on 230V 50 60Hz You can use a powerCON link cable to connec...

Страница 15: ...ill turn on making it possible to see in places that would otherwise be dark in the Stage Flame 6 Set the Stage Flame power button to on 5 Connect the other end of the DMX cable male plug to a profess...

Страница 16: ...fter the Stage Flame has been in use for a period of time So always let the Stage Flame cool off before replacing the aerosol can Always remember that escaping gas can ignite at high temperatures Afte...

Страница 17: ...turned in completely to maximize the flow of gas and create the biggest possible flame We recommend turning the bolt to the maximum opening to get the best results The reducer must never be used with...

Страница 18: ...ting flames These options are dependent on the gas sources you choose to use The three options are Option 1 Aerosol can Option 2 Propane cylinder Option 3 Big Flame aerosol can and gas bottle You sele...

Страница 19: ...aerosol can and a gas bottle 1 7 After you have set the safety channel you can set the fire channel You select the desired channel by using the UP and DOWN buttons If you have selected the Big Flame o...

Страница 20: ...flame should now be emitted from the Stage Flame Before you shoot flames always check that there are no persons in the area near the Stage Flame Ensure that you have a full view of the Stage Flame wh...

Страница 21: ...ed the Stage Flame you must set it to safety mode again You put the Stage Flame in safety mode by shutting the safety channel or setting it to a value outside the 40 to 60 range The Stage Flame cannot...

Страница 22: ...age Flame is cooled off before you remove the aerosol can and pack up the Stage Flame 4 If a gas bottle was used then this must be closed first before you disconnect the gas hose 3 Turn off the Stage...

Страница 23: ...life of the Stage Flame for as long as possible you must regularly clean it and test that it is working properly Regardless of the reason contact MAGIC FX if the Stage Flame does not work properly DAN...

Страница 24: ...WWW MAGICFX EU...

Отзывы: