compressor is generally controlled by a thermostat . When the temperature in the 

refrigerator reaches its desired value, the thermostat will shut down the compressor 

automatically. Never take this normal operation as a trouble, care should be taken to 

differentiate it from other real troubles in servicing.

D. Compressor won ‹t start In case the compressor cannot be started, you must find 

out the origins of this trouble through checkup step by step, because probably there are

many causes, including those electrical and mechanical.

1) Inspect the power supply to see whether it is connected to the compressor circuit. 

Analysis of Trouble

In case the compressor cannot be started, this will generally exhibit in

the power supply circuit, for instance, power failure, poor contact of switch,

and blown fuse. Make a comprehensive analysis of these phenomena, fine

out its real cause and take correct measures to remove this trouble.

Remedy

 a) Check the input power circuit to see whether where is voltage of the power supply, 

namely, the circuit which is connected to the knife switch. This can be determined with 

an avometer or a test pencil. If a blown fuse is found, ascertain and remove its cause, 

then replace it with a new one of the same specifications.

b) Check the compressor accessories, including its thermal protector and relay. In case 

the thermal protector is damaged, the compressor cannot be powered on. If the relay 

is out of order, the motor will not run and hum sound can be heard from it after the 

compressor is turned on, in that case, shut it down immediately, otherwise, the motor 

windings will be burned out in case this condition lasts longer.

c) Check the relay contacts and plugs to see if they are perfect and work reliably. Poor 

contact may cause the motor not running or humming.

2) Check the circuit voltage to see whether it is normal. Analysis of trouble If the circuit 

voltage is obviously lower than its rated value, it will be difficult to start the motor, and 

a hum sound can be heard from it. Remedy Measure the voltage with a voltmeter, if it 

is really too low, give directions to the user for buying a stabilizer so as to step up the 

voltage, thus normal operation can be achieved.

3) Check the thermal relay to see whether its contacts are closed. Analysis of Trouble The 

contacts of thermal relay sometimes may be open due to the leakage of temperature 

air is higher gas discharge pressure, higher discharged gas temperature (the gas discharge 

tubing is considerably hot when you feel it with your hand), and poorer refrigerating 

effect. Furthermore, the gas discharge pressure will exceed its normal value when the 

compressor has run for a period not too long, thus making the protective relay actuate 

and bring to a stoppage. Remedy Check up how the air has been left in the refrigerating 

system. Generally, there are two possibilities: one is that the air has been sucked into the 

system when repairing due to carelessness, or it has not been purged out totally when 

evacuating the system; the other is that there are leak points at the low pressure end 

of the refrigerating system. Leak points appear mostly in those low temperature parts 

or assemblies, because the evaporation temperature is lower for such low temperature 

devices, especially at the low pressure end, it is easier for the air goes into the system. 

Once it has been ascertained that air does exist in the system, you have to open the 

tubing, re-evacuate it and then charge it with refrigerant.

2) Stoppage due to electric troubles

a) Thermostat is out of control Analysis of Trouble In case the thermostat does not work 

in its good order or its temperature sensor has not been installed properly, frequent 

stoppage is also likely to occur. Remedy Try to adjust the temperature sensor›s position 

until the compressor can be started and stopped normally. If this cannot be achieved, 

and the stoppage still occurs repeatedly, it is most likely that the mechanical parts or 

contacts are out of order, disassemble the thermostat, make a thorough checkup and 

repair it.

b) Overload of electric motor Analysis of Trouble Probably, too many things have been 

put into the refrigerator, and hence the thermal load exceeds its refrigerating capacity ; 

or in case the power supply voltage drops considerably, the current flowing through the 

motor will increase drastically making the thermal protector actuate and the fuse blown 

, and hence the motor stops running. If the motor is still running continuously in such a 

case , its windings will be burned out . Remedy Reduce the thermal load, pay attention 

to the variation in voltage of the power supply.

c) Abnormal thermal protection

Analysis of Trouble The compressor current is within its normal range, but the thermal 

protector actuates repeatedly. Remedy Replace the thermal protector with a new one.

3)  Sudden  stoppage  due  to  other  causes  Normal  Stoppage  Start  and  stop  of  the 

Содержание MCSR-6085W

Страница 1: ...Please read the following instructions completely before operating this appliance INSTRUCTION MANUAL REFRIGERATOR MCSR 6085W MCSR 6085B MCSR 6085BSS MCSR 5585W MCSR 5283W MCSF 5585BSS...

Страница 2: ...icefromsurfacesoftherefrigeratorand orfreezercompartment Doingsocouldpuncturethecoolingcoil causingtheunittoloseitsabilitytomaintaincoldtemperaturesandvoidingthewarranty SeetheCareandCleaningsectionfo...

Страница 3: ...CTRICITY 4 operationinstruction 5 ControlSettings 5 Abouttherefrigeratorfeatures 6 Careandcleaningoftherefrigerator 6 Careandcleaningoftherefrigerator 6 Careandcleaningoftherefrigerator 7 Preparingtoi...

Страница 4: ...ibility andobligationtohaveitreplacedwithaproperlygrounded3 prongwalloutlet The refrigerator should always be plugged into its own individual electrical outlet whichhasavoltageratingthatmatchestherati...

Страница 5: ...emilktest Placeacontainerofmilkonashelfandcheckitadaylater Ifthemilkis toowarmortoocold adjustthetemperaturecontrol Afterchangingthecontrol allow This provides the best performance and also prevents o...

Страница 6: ...side To help prevent odors leave an open box of baking soda in the refrigerator Unplug the refrigerator before cleaning If this is not practical wring excess moisture out of sponge or cloth when clean...

Страница 7: ...r unscrew the lens and pull horizontally until the lens is removed Gently unscrew the light bulb and replace with a bulb of 15 watts orless Careandcleaningoftherefrigerator Defrosting Defrost whenever...

Страница 8: ...yandcarefully RefrigeratorLocation Do not install the refrigerator where the temperature will go below 50 F 10 C becauseitwillnotrunoftenenoughtomaintainpropertemperatures Installitonafloorstrongenoug...

Страница 9: ...erator 12 Re install the adjustable legs Insure that the smaller leg is on the same side as the bottomhinge 13 Placethefreshfooddooronthebottomhinge 14 Place the bottom peg of the middle hinge in the...

Страница 10: ...10 Troubleshootingtips Savetimeandmoney...

Страница 11: ...Safety precautions...

Страница 12: ...12 Safetyprecautions...

Страница 13: ...Thickinsulationforenergyefficiency SystemFlowChart 1 SchematicdiagramofSystemFlowChart 2BriefDescriptionofSystemFlowChart Allmodelsareadirectcoolingsingle systemrefrigeratororfreezer Whenthe refriger...

Страница 14: ...oting 1 Nocooling CircuitDiagram 1SchematicCircuitDiagram BriefDescriptionofControlPrinciple Amechanicaltypeofallthecontrolisgenerallyadopted Thethermostatdirectlycontrolsthestartandstopofcompressor a...

Страница 15: ...15 3Coolingcapacityisinsufficient 2Thecompressordoesn tstop...

Страница 16: ...tstoppedrunning arumblingsoundcanbeheardfrominsideits evaporator Thisisasoundcausedbytheflowingofrefrigerantintheevaporatortubing Because the pressure difference is still greater after the compressor...

Страница 17: ...inside the compressor this means that some moving parts have loosened note to differentiate this sound from thoseformedduringstartingorstoppingthecompressor 4 For the direct cooling refrigerator a kin...

Страница 18: ...othosepartsthatareliableto leak check main connection points for oil seepage and tubing for cracks If there is no b ListentothesoundcausedbytheflowingofgasintheevaporatorOpentherefrigerator doorwhilet...

Страница 19: ...r the heat conduction effect will be severer leak point charge the system with nitrogen and detect leak points with the commonlyadoptedmethod repairthem evacuate chargethesystemwithrefrigerant andthen...

Страница 20: ...ntly sometimes therefrigeratorworkswell andsometimesnotwell Inorder todeterminewhetheritiscloggedwithice heatthesuspiciouspointswithhotwaterto make ice melt and after a while if a gas flowing sound re...

Страница 21: ...e system with a properquantityofrefrigerant b Air left in the system Analysis of Trouble The residual air in the system will circulate togetherwiththerefrigerantinthesystem Themajorsymptomscausedbythi...

Страница 22: ...ue to the leakage of temperature airishighergasdischargepressure higherdischargedgastemperature thegasdischarge tubing is considerably hot when you feel it with your hand and poorer refrigerating effe...

Страница 23: ...ationtemperatureinthesystemistoo high thetemperaturesensingagentinthetemperaturesensorisalsohotter therefore sensing agent from the temperature sensor Remedy Remove the relay cover to check up its con...

Страница 24: ...dthattherefrigerantinthesystemisinsufficientinquantity recharge it with refrigerant In case clogging occurs disassemble the part where it is blocked If the evaporation temperature is too high settle t...

Страница 25: ...25...

Страница 26: ...26...

Страница 27: ...27...

Страница 28: ...28...

Страница 29: ...29...

Страница 30: ...30...

Страница 31: ...31...

Страница 32: ......

Отзывы: