DC Power Connector: 

 

Magenta provides ready-to-use power supplies for MultiView™ II products. However, if there is a reason a 
substitute power supply must be used, then the following information is important for maintaining product 
reliability and performance: 
 
Magenta AC/DC Power supply output rating:  

Reg5VDC @ 3Amps. 

 
Power-input rating for MultiView™-DVI-TX:  

5VDC, 1.2Amps max. 

 
The DVI-TX’s DC power input connector accepts an industry-standard coaxial-DC plug with the following 
specifications: 
 

 

Coaxial power connector 

 

OD = 5.5mm 

 

ID = 2.5mm (accepted center-pin diameter) 

 

Length = 11mm (overall length of insertable plug end) 

 

Inner contact (pin-socket) = +5VDC 

 

Outer contact (sleeve) = Ground 

 
It is highly recommended that the inner contact (center-pin contact) of any mating DC plug utilize a “tuning-fork” 
shaped design, rather than a plain barrel shape. The tuning-fork design greatly increases the reliability of the 
power connection. The plain barrel style connector can cause intermittent operation, often resulting in 
“mysterious” system problems that are difficult to identify. 
 

 
     
 

 

 

 

 

 

 

 

 

 

 

 

The Magenta-provided power supply already comes with the correct output ratings and DC-
plug configuration 

 

 

 

Plain barrel center contact. 

NOT RECOMMENDED 

Tuning-fork center 

contact. 

PREFERRED 

Содержание MultiView II DVI-TX

Страница 1: ...Document 5310258 01 Rev 01 12 19 2011 MultiView II DVI TX Transmitter Installation and User Guide TM...

Страница 2: ...ftware or documentation including their quality performance merchantability or fitness for a particular purpose As a result this software or documentation is licensed as is and you the licensee are as...

Страница 3: ...losure which may present a risk of electric shock damage to equipment or facilities Caution Read instructions Read and understand all operating installation and safety instructions before using this e...

Страница 4: ...Tat Centre Chai Wan Hong Kong Main 852 3105 1493 Fax 852 3105 1491 Contact awaung magentaresearch asia com Sales awaung magentaresearch asia com Pan European Office Magenta Research LTD Main 44 7708...

Страница 5: ...232 version 7 3 4 3 Auxiliary Signal support SA version 7 3 4 4 Auxiliary Signal support SAP version 8 3 5 CAT5 Cable Compatibility 8 Chapter 4 Installation 9 4 1 Prerequisites 9 4 2 Installation Proc...

Страница 6: ...configuration setting MVII DVI TX S o Supports simplex serial user configuration setting MVII DVI TX 232 o Supports 9 wire RS 232 serial simplex or duplex TX RX with hardware handshaking o Contains t...

Страница 7: ...ultiView extension and switching systems 2 1 Front Panel interfaces The front panel of the DVI TX has the following ports controls and indicators There are two buttons COPY CFG and DDC MODE SEL and se...

Страница 8: ...nce Local output port drive impedance Standard DVI interface specifications apply at local video output port DDC EDID is supported Audio Characteristics Standard A version Left Right summed audio 232...

Страница 9: ...r 1 DVI I output connector Note The analog VGA signals on the DVI I connector are not supported Audio Characteristics Embedded digital audio is not supported For summed L R analog audio input please s...

Страница 10: ...th a specific display that would otherwise not work properly if simply using the factory default DDC EDID profile Finally the DVI TX supports a pass through mode where the DDC EDID profile of a locall...

Страница 11: ...ing allows either the A or S versions to support digital S PDIF audio The option module 232 SA SAP is a factory installed option However a field upgrade to a 232 SA or SAP version is possible It will...

Страница 12: ...In applications where a DVI TX 232 transmitter is routed through a DA Distribution Amp such as a MultiView 9D for example or a Mondo or other video switch the 232 module will provide simplex serial TX...

Страница 13: ...still works and audio In this mode receive direction serial data RX is ignored 3 5 CAT5 Cable Compatibility The MultiView family of products enable the highest quality video extension over common Cate...

Страница 14: ...ended for nor does it support distribution through an Ethernet network Do not connect these devices to any sort of networking or telecommunications equipment Do not connect DC power until instructed t...

Страница 15: ...led LOCAL OUT 3 Connect the CAT5 cable to the transmitter LINK OUT port 4 Make your audio or serial connections via the phoenix AUX I O connector or DB9 IOIO serial connector as appropriate for your D...

Страница 16: ...Connect the CAT5 cable to the LINK IN connector If you are daisy chaining multiple receivers also connect the downstream CAT5 cable to the LINK OUT port on the receiver 3 Apply power to the receiver...

Страница 17: ...C operating mode For all other configuration settings the DVI TX must be in CONFIG mode CFG indicator is on Once in CONFIG mode any changes are effective immediately and are saved in non volatile memo...

Страница 18: ...upport the most popular VESA standards in standard or widescreen formats To activate STD mode press the DDC MODE button until the STD indicator is on LOCAL Selects the DDC EDID profile from a locally...

Страница 19: ...smitter is in the normal operating state CFG indicator is off Press and release the CFG button once to access configuration mode CFG indicator on Press and release the SEL button once You will now be...

Страница 20: ...change 4th pair option settings LED indicators 4 6 should be illuminated either DIM or ON all others indicators 1 3 7 and 8 should be off Press the CFG button repeatedly to step through the available...

Страница 21: ...signal s refresh rate may be set too high Reset to a lower refresh rate in your display configuration menu for example under Windows on a PC There may be a video skew delay issue See section on skew a...

Страница 22: ...SAP units a maximum of 12 units may be daisy chained within the rated cable length of the receiver if using standard CAT5 6 or a maximum of 8 units may be daisy chained within the rated cable length o...

Страница 23: ...provides the pin out for all 24 pins which are used in the DVI TX unit providing 2 x 165MHz bandwidth Pin Signal Name Pin Signal Name Pin Signal Name 1 TMDS Data 2 9 TMDS Data 1 17 TMDS Data 0 2 TMDS...

Страница 24: ...PIN A Audio S Simplex Serial SPDIF Audio Composite Video SA Audio SAP Audio 1 SIG1 Left Channel Tx Signal Signal Left Channel Left Channel 2 GND Ground ground Signal Signal Ground Ground 3 SIG2 Right...

Страница 25: ...lug DB9 Female to Male is used to connect an external serial device for example a PC to the DVI TX transmitter The DB9 F serial port is only available on DVI TX 232 SA and SAP models DVI TX 232 Simple...

Страница 26: ...21 RJ45 MultiView Link Wiring Standard PIN COLOR PAIR 1 White Orange Stripe 2 2 Orange Solid 2 3 White Green Stripe 3 4 Blue Solid 1 5 White Blue Stripe 1 6 Green Solid 3 7 White Brown Stripe 4 8 Brow...

Страница 27: ...tions Coaxial power connector OD 5 5mm ID 2 5mm accepted center pin diameter Length 11mm overall length of insertable plug end Inner contact pin socket 5VDC Outer contact sleeve Ground It is highly re...

Страница 28: ...module from the main board Transmitter 232 module jumper settings Mode Type Baud Max JP1 1 2 JP1 3 4 1 Simplex one way to 1500 ft 115k OUT IN 2 Full Duplex 2 way Short 500 ft 19 2K OUT OUT 3 5 Default...

Страница 29: ...to 1500 ft 115k 1 2 See Notes 3 4 See Notes 5 6 IN 7 8 IN 9 10 OUT 1 2 IN 3 4 OUT 5 6 OUT 7 8 IN 9 10 OUT 5 Default Full Duplex 2 way Long to 1500 ft 19 2k 1 2 OUT 3 4 OUT 5 6 OUT 7 8 IN 9 10 OUT 1 2...

Страница 30: ...the SAP receiver s address switches you will need to open the receiver enclosure and set the DIP switches directly on the SAP module The DIP switch has 8 switches one for each address bit position Us...

Страница 31: ...FF 1 2 3 4 8 OFF 1 5 ON 1 5 6 ON 1 5 7 ON 1 5 6 7 ON 2 3 4 6 7 8 OFF 2 3 4 7 8 OFF 2 3 4 6 8 OFF 2 3 4 8 OFF 2 5 ON 2 5 6 ON 2 5 7 ON 2 5 6 7 ON 1 3 4 6 7 8 OFF 1 3 4 7 8 OFF 1 3 4 6 8 OFF 1 3 4 8 OFF...

Страница 32: ...N 1 5 6 7 8 ON 2 3 4 6 7 OFF 2 3 4 7 OFF 2 3 4 6 OFF 2 3 4 OFF 2 5 8 ON 2 5 6 8 ON 2 5 7 8 ON 2 5 6 7 8 ON 1 3 4 6 7 OFF 1 3 4 7 OFF 1 3 4 6 OFF 1 3 4 OFF 1 2 5 8 ON 1 2 5 6 8 ON 1 2 5 7 8 ON 1 2 5 6...

Страница 33: ...ith 16 device mounting screws 4 rack mounting screws Note When installing DVI TX devices in an area susceptible to elevated operating temperatures near the maximum specified operating temperature it i...

Страница 34: ...ble from Magenta Research as an aid in system design and configuration You may download them from the Magenta website www magenta research com There is no charge for obtaining these drawings Drawing D...

Страница 35: ...reil numerique de la classe A est conforme a la norme NMB 003 du Canada EUROPEAN UNION DECLARATION OF CONFORMITY Warning This is a Class A product In a domestic environment this product may cause radi...

Страница 36: ...ts 28 Option Module Settings 232 option module 23 SAP option module 25 Pinouts 18 Auxiliary Signal Port 19 DVI Ports 18 Phoenix Connector 19 Power Connector 22 Serial Port 20 UTP CAT5 Link Port 21 Pre...

Отзывы: