background image

 

4. Troubleshooting 

 

4.1 Common Problems 

 

In most cases, nearly every issue with the MultiView™ Series can be resolved by 
checking the AC mains and DC connections to each of the MV units.  

 

Problem:               

No power LED at Mini Dense Pack. 

 

Solution:            

• Check AC connection at both unit and at outlet 

                              • Ensure Mini Dense Pack is plugged in and outlet is live. 
                              • Check fuse at AC switch inlet. 

 
Problem:               

Powered Unit shuts off after period of time 

 

Solution:            

• 

Over current situation may be present, causing DC port protection 

                                device to shut down port. Check DC cable for shorts or mis-pining. 

 
Problem:               

Mini 

Dense Pack  turned on, but no or low voltage at outputs. 

 

Solution:            

• Check for  unit load exceeding units maximum rating.             

                              • Check for over temperature condition ( lack of rack ventilation ). 
                                 ( power supply entered thermal shutdown )  
                              • Check for cabling issues ( one output shorted to another output)  
                                 

 

 

 

 

 

MAGENTA MULTIVIEW™ MINIDENSE PACK POWER SUPPLY . 

 

Appendix A. Cabling Pinouts

 

 
   
 
 

Mini Dense Pack End 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

2.5mm Center Positive 

5.5mm Ring  minus 

MultiView Device End 