background image

MG6250

2-Partition 64-Zone Wireless Console with GPRS/GSM

Version 1.6

Section Programming Guide

Содержание MG6250

Страница 1: ...MG6250 2 Partition 64 Zone Wireless Console with GPRS GSM Version 1 6 Section Programming Guide ...

Страница 2: ...am user codes This code can be either four or six digits in length The system master code cannot be changed by the installer or maintenance code System Reset To reset the system to its default factory settings press and hold the and buttons during system power up or access section 9000 For more information refer to MG6250 Reset Sections on page 3 Demo Mode Demo mode provides a quick preview of the...

Страница 3: ... values Installer Quick keys Installer quick keys provide shortcuts for certain system actions Refer to table 2 for a description of these quick keys To access the installer quick keys 1 Press and hold 0 2 Enter your installer code default is 0000 000000 or maintenance code 3 Press the required quick keys see table 2 Table 2 Installer quick key values MG6250 Reset Sections Table 1 Decimal and hexa...

Страница 4: ...tion Reporting Telephone Number 21 Channel Reporting Format Telephone 21 Central Station Account Number 21 IP GPRS Programming 21 GSM GPRS Gentle Retries 22 Report Codes 23 Special Disarming Disarming After Alarm Cancelling Alarm Report Codes 23 Special Arming Report Codes 23 Special Disarming Report Codes 23 Alarm Fire Alarm Report Codes 23 Alarm Restore Fire Alarm Restore Report Codes 24 Special...

Страница 5: ...l Characters V1 2 and up 42 Installation 49 Wall mount Installation 49 DC Power 49 Backup Battery Pack 49 Telephone Line Connections 50 Programmable Outputs PGMs 50 Hardwire Zone Connections 51 Appendix A EN 50131 Programming 52 System Timers 52 General Options A 52 Arming Disarming Options 52 Wireless Module Options 53 Further Requirements 54 Technical Specifications 54 ...

Страница 6: ...21 24 hr freeze 22 24 hr panic 23 Follow no pre alarm Not armed 24 Instant no pre alarm Not armed 25 Keyswitch maintain 26 Keyswitch momentary 27 Delay 1 sleep full arm Not armed Not armed Entry delay 1 Entry delay 1 28 Delay 2 sleep full arm Not armed Not armed Entry delay 2 Entry delay 2 29 Unarmed Not armed Not armed Not armed Not armed 30 32 Future use 33 Custom template 1 Not armed Instant In...

Страница 7: ...0017 17 1 2 3 4 5 6 7 8 0018 18 1 2 3 4 5 6 7 8 0019 19 1 2 3 4 5 6 7 8 0020 20 1 2 3 4 5 6 7 8 0021 21 1 2 3 4 5 6 7 8 0022 22 1 2 3 4 5 6 7 8 0023 23 1 2 3 4 5 6 7 8 0024 24 1 2 3 4 5 6 7 8 0025 25 1 2 3 4 5 6 7 8 0026 26 1 2 3 4 5 6 7 8 0027 27 1 2 3 4 5 6 7 8 0028 28 1 2 3 4 5 6 7 8 0029 29 1 2 3 4 5 6 7 8 0030 30 1 2 3 4 5 6 7 8 0031 31 1 2 3 4 5 6 7 8 0032 32 1 2 3 4 5 6 7 8 0033 33 1 2 3 4 ...

Страница 8: ...5 6 7 8 0059 59 1 2 3 4 5 6 7 8 0060 60 1 2 3 4 5 6 7 8 0061 61 1 2 3 4 5 6 7 8 0062 62 1 2 3 4 5 6 7 8 0063 63 1 2 3 4 5 6 7 8 0064 64 1 2 3 4 5 6 7 8 Section Description Disarm Stay Arm Sleep Arm Full Arm 0091 Zone definition template 1 0 0 0 8 0 8 0 8 0092 Zone definition template 2 0 0 0 0 0 8 0 8 0093 Zone definition template 3 0 0 0 1 0 8 0 1 0094 Zone definition template 4 0 0 0 8 0 8 0 1 S...

Страница 9: ...6 36 0237 37 0238 38 0239 39 0240 40 0241 41 0242 42 0243 43 0244 44 0245 45 0246 46 0247 47 0248 48 0249 49 0250 50 0251 51 0252 52 0253 53 0254 54 0255 55 0256 56 0257 57 0258 58 0259 59 0260 60 0261 61 0262 62 0263 63 0264 64 Section Doorbell Doorbell Serial Number 0271 1 0272 2 Section Doorbell Tone 0281 1 0282 2 00 Tone 1 01 Tone 2 02 Tone 3 03 Tone 4 Section Doorbell Doorbell Label 0291 1 02...

Страница 10: ...vation Deactivation Event 00 00 0 0328 PGM8 Activation Deactivation Event 00 00 0 Option Description PGM 1 0341 PGM 2 0342 PGM 3 0343 PGM 4 0344 PGM 5 0345 PGM 6 0346 PGM 7 0347 PGM 8 0348 OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON 1 PGM time base OFF Sec ON Min 2 Console supervision 3 Wireless PGM supervision 4 Voice control 5 Remote output time base OFF Sec ON Min 6 Future use 7 Fut...

Страница 11: ...REM1 REM2 RAC1 RAC2 REM3 REM15 and REM101 Section Remote Remote Control Serial Number 0401 RC1 0402 RC2 0403 RC3 0404 RC4 0405 RC5 0406 RC6 0407 RC7 0408 RC8 0409 RC9 0410 RC10 0411 RC11 0412 RC12 0413 RC13 0414 RC14 0415 RC15 0416 RC16 Table 8 Button options for MG6250 remote controls see Decimal and Hexadecimal Programming Table on page 3 Option Description Option Description 0 Empty button disa...

Страница 12: ...3 Remote Control PGM 1 9 PGM 2 0 PGM 3 x PGM 4 PGM 5 PGM 6 PGM 3 4 x PGM 5 6 Default Data 6 7 8 9 A B 0 0 RC Section All 0440 1 0441 2 0442 3 0443 4 0444 5 0445 6 0446 7 0447 8 0448 9 0449 10 0450 11 0451 12 0452 13 0453 14 0454 15 0455 16 0456 17 0457 18 0458 REM1 REM2 RAC1 RAC2 REM15 Reg Arm PGM1 PGM2 Dis Default Data 4 6 7 0 RC Section All 0440 1 0441 2 0442 3 0443 4 0444 5 0445 6 0446 7 0447 8...

Страница 13: ...ture use 8 Future use Section User User Label Section User User Label 0521 1 0529 9 0522 2 0530 10 0523 3 0531 11 0524 4 0532 12 0525 5 0533 13 0526 6 0534 14 0527 7 0535 15 0528 8 0536 16 Section Keypad Keypad Serial Number 0601 1 0602 2 0603 3 0604 4 Section Keypad Keypad Label 0611 1 0612 2 0613 3 0614 4 Section Option Description OFF ON 0620 1 Wireless keypad 1 supervision Disabled Enabled 2 W...

Страница 14: ...eless repeater 4 supervision Disabled Enabled 5 Future use 6 Future use 7 Future use 8 Future use Option Description RPT 1 0721 RPT 2 0741 RPT 3 0761 RPT 4 0781 OFF ON OFF ON OFF ON OFF ON 1 Repeater wireless zone 1 2 Repeater wireless zone 2 3 Repeater wireless zone 3 4 Repeater wireless zone 4 5 Repeater wireless zone 5 6 Repeater wireless zone 6 7 Repeater wireless zone 7 8 Repeater wireless zo...

Страница 15: ... 1 0725 RPT 2 0745 RPT 3 0765 RPT 4 0785 OFF ON OFF ON OFF ON OFF ON 1 Repeater wireless zone 33 2 Repeater wireless zone 34 3 Repeater wireless zone 35 4 Repeater wireless zone 36 5 Repeater wireless zone 37 6 Repeater wireless zone 38 7 Repeater wireless zone 39 8 Repeater wireless zone 40 Option Description RPT 1 0726 RPT 2 0746 RPT 3 0766 RPT 4 0786 OFF ON OFF ON OFF ON OFF ON 1 Repeater wirel...

Страница 16: ...er wireless zone 62 7 Repeater wireless zone 63 8 Repeater wireless zone 64 Option Description RPT 1 0729 RPT 2 0749 RPT 3 0769 RPT 4 0789 OFF ON OFF ON OFF ON OFF ON 1 Wireless keypad 1 2 Wireless keypad 2 3 Wireless keypad 3 4 Wireless keypad 4 5 Future use 6 Future use 7 Future use 8 Future use Option Description RPT 1 0730 RPT 2 0750 RPT 3 0770 RPT 4 0790 OFF ON OFF ON OFF ON OFF ON 1 Wireless...

Страница 17: ...hone Number action through SMS Display only 1002 Console IP Address Display only 1003 Console IP Port 1004 Future use 1005 APN Site Name 1006 APN User Name 1007 APN Password 1008 Console GSM Status Viewer Display only 1009 Console GSM Status Viewer Raw Display only 1010 SMS forwarding provider s phone number 1011 CME CMS error Display only Section Description Data 1021 Console SMS Telephone Number...

Страница 18: ...3 1103 1113 1123 1135 to 1136 1191 to 1198 4 1104 1114 1124 1137 to 1138 1211 to 1288 5 1105 1115 1125 1139 to 1140 1231 to 1238 6 1106 1116 1126 1141 to 1142 1251 to 1258 7 1107 1117 1127 1143 to 1144 1271 to 1278 8 1108 1118 1128 1145 to 1146 1291 to 1298 Section Telephone Number Telephone Number 1101 1 1102 2 1103 3 1104 4 1105 5 1106 6 1107 7 1108 8 Section Format 1111 1112 1113 1114 1115 1116...

Страница 19: ...m Selection A Section Option Description OFF ON 1151 1 Zone 1 Disabled Enabled 2 Zone 2 Disabled Enabled 3 Zone 3 Disabled Enabled 4 Zone 4 Disabled Enabled 5 Zone 5 Disabled Enabled 6 Zone 6 Disabled Enabled 7 Zone 7 Disabled Enabled 8 Zone 8 Disabled Enabled Zone Alarm Selection B Section Option Description OFF ON 1152 1 Zone 9 Disabled Enabled 2 Zone 10 Disabled Enabled 3 Zone 11 Disabled Enabl...

Страница 20: ...d Zone Alarm Selection F Section Option Description OFF ON 1156 1 Zone 41 Disabled Enabled 2 Zone 42 Disabled Enabled 3 Zone 43 Disabled Enabled 4 Zone 44 Disabled Enabled 5 Zone 45 Disabled Enabled 6 Zone 46 Disabled Enabled 7 Zone 47 Disabled Enabled 8 Zone 48 Disabled Enabled Zone Alarm Selection G Section Option Description OFF ON 1157 1 Zone 49 Disabled Enabled 2 Zone 50 Disabled Enabled 3 Zo...

Страница 21: ...GPRS Receiver 1 WAN 1 IP Address 1512 IP GPRS Receiver 2 WAN 1 IP Address 1521 IP GPRS Receiver 1 WAN 2 IP Address 1522 IP GPRS Receiver 2 WAN 2 IP Address 1531 IP GPRS Receiver 1 WAN 1 IP port 1532 IP GPRS Receiver 2 WAN 1 IP port 1541 IP GPRS Receiver 1 WAN 2 IP port 1542 IP GPRS Receiver 2 WAN 2 IP port 1551 IP GPRS Receiver 1 password 1552 IP GPRS Receiver 2 password 1553 SMS Receiver 1 passwo...

Страница 22: ...Disabled Enabled 2 Future use 3 Future use 4 Future use 5 Future use 6 Future use 7 Future use 8 Future use Option Enabled GSM registration retry sequence 5 min 5 min 5 min 5 min 30 min then every 60 min GPRS activation retry sequence 1min 1min 1min 1min 15 min then every 30 min Option Disabled GSM registration retry sequence every 30 seconds GPRS activation retry sequence every 1 min ...

Страница 23: ... 1618 Quick arming Late to close Arming via PC No movement Keyswitch arming Partial arming Future use Default FF Section Description Data Section Description Data 1619 End auto arm 1620 Cancel paramedic alarm Software disarm Keyswitch disarm Software disarm after alarm Keyswitch disarm after alarm Software cancel alarm Keyswitch cancel alarm Default FF Section Description Data Section Description ...

Страница 24: ...rm fire 51 Alarm fire 55 Alarm fire 52 Alarm fire 56 Section Description Data Section Description Data 1635 Alarm fire 57 1636 Alarm fire 61 Alarm fire 58 Alarm fire 62 Alarm fire 59 Alarm fire 63 Alarm fire 60 Alarm fire 64 Default FF Section Description Data Section Description Data 1641 Alarm fire restore 01 1642 Alarm fire restore 05 Alarm fire restore 02 Alarm fire restore 06 Alarm fire resto...

Страница 25: ...8 Section Description Data Section Description Data 1653 Alarm fire restore 49 1654 Alarm fire restore 53 Alarm fire restore 50 Alarm fire restore 54 Alarm fire restore 51 Alarm fire restore 55 Alarm fire restore 52 Alarm fire restore 56 Section Description Data Section Description Data 1655 Alarm fire restore 57 1656 Alarm fire restore 61 Alarm fire restore 58 Alarm fire restore 62 Alarm fire res...

Страница 26: ... 42 Zone tamper 46 Zone tamper 43 Zone tamper 47 Zone tamper 44 Zone tamper 48 Section Description Data Section Description Data 1673 Zone tamper 49 1674 Zone tamper 53 Zone tamper 50 Zone tamper 54 Zone tamper 51 Zone tamper 55 Zone tamper 52 Zone tamper 56 Section Description Data Section Description Data 1675 Tamper Zone 57 1676 Tamper Zone 61 Tamper Zone 58 Tamper Zone 62 Tamper Zone 59 Tamper...

Страница 27: ...9 Zone tamper restore 36 Zone tamper restore 40 Section Description Data Section Description Data 1691 Zone tamper restore 41 1692 Zone tamper restore 45 Zone tamper restore 42 Zone tamper restore 46 Zone tamper restore 43 Zone tamper restore 47 Zone tamper restore 44 Zone tamper restore 48 Section Description Data Section Description Data 1693 Zone tamper restore 49 1694 Zone tamper restore 53 Zo...

Страница 28: ... loss restore GSM missing module restore 1723 IP no service restore 1724 Fail to communicate personal reporting restore IP supervision loss restore Future use IP receiver supervision lost restore Future use Fail to comm with central st restore Future use Default FF Section Description Data Section Description Data 1731 Zone battery trouble 1732 Zone battery trouble restore Zone supervision loss Zo...

Страница 29: ...rouble Wireless siren battery trouble restore Wireless siren AC trouble Wireless siren AC trouble restore Default FF Section Description Data 1741 Wireless remote battery trouble Wireless remote battery trouble restore Future use Future use Default FF Section Option Description OFF ON 2000 1 Access code length 6 Digits 4 Digits 2 Audible trouble warning except AC power failure Disabled Enabled 3 A...

Страница 30: ...ming Disabled Enabled 7 One touch Sleep arming Disabled Enabled 8 One touch Full arming Disabled Enabled Section Option Description OFF ON 2004 1 Future use 2 Report Zone restore On bell cut off On zone closure 3 4 Tamper recognition options console tamper follows this option 3 4 Disabled OFF OFF Trouble only OFF ON Disarmed Trouble only Armed Follow zone s alarm type ON OFF Disarmed Audible alarm...

Страница 31: ...ng Options 1 2 GPRS monitoring disabled OFF OFF Trouble only ON OFF Disarmed Trouble only Armed Audible alarm OFF ON Silent alarms become audible ON ON 3 4 Future use 5 Live event encrypted on external serial port Disabled Enabled 6 Live events on external serial port Disabled Enabled 7 Live events on modem when connected Disabled Enabled 8 Live events on GPRS when connected Disabled Enabled Secti...

Страница 32: ...M fail timer ____ ____ ____ seconds 032 sec 2035 Delay alarm transmission ____ ____ ____ seconds Disabled 2036 Delay between dialling attempts ____ ____ ____ seconds maximum 130 seconds 020 sec 2037 Lowest rate primary communication ____ ____ 01 landline 02 GSM Disabled 2038 Auto test report ____ ____ ____ days Disabled 2039 Auto test report time ____ ____ ____ ____ Disabled 2040 GSM network failu...

Страница 33: ...F Stay arm ON OFF Sleep arm OFF ON Full arm ON ON 3 4 Auto arm no movement 3 4 Disabled OFF OFF Stay arm ON OFF Sleep arm OFF ON Full arm ON ON 5 Switch to Stay arming if no entry delay zone is opened Disabled Enabled 6 Follow zones become Entry Delay 2 zones when Delay Zone is bypassed Disabled Enabled 7 No exit delay when arming with remote control Disabled Enabled 8 Exit delay termination Disab...

Страница 34: ...ion Data 2300 Section Code Data 2301 Installer Code 2302 Maintenance Code Section Software Login Data 2401 Installer Software Username 2402 Installer Software Password 2411 Maintenance Software Username 2412 Maintenance Software Password Section Option Description OFF ON 2501 1 Area 1 access right Disabled Enabled 2 Area 2 access right Disabled Enabled 3 Bypass Disabled Enabled 4 Future use 5 Futu...

Страница 35: ...n Saved Events Table 10 Non Reportable Events Non Saved Events Event Event Description Sub event Sub event Description Area 00 Zone OK 01 64 99 Zone number 1 2 3 01 Zone open 02 Partition status 02 Silent alarm 1 2 3 03 Buzzer alarm 04 Steady alarm 05 Pulse alarm 06 Strobe 07 Alarm stopped 08 Squawk ON 09 Squawk OFF 10 Ground start 11 Disarm partition 12 Arm partition 13 Entry delay started 14 Exi...

Страница 36: ...e 1 22 Missing SIM card 23 StayD mode activated 1 2 3 24 StayD mode deactivated 25 IP registration status change 1 26 GPRS registration status change 27 Remote access denied 28 Fail to communicate to central station channel s 1 2 3 29 Fail to communicate to central station channel s restore 1 2 3 30 User call ended due to central polling 1 07 Remote access 01 16 User number 1 2 3 99 Any user numbe...

Страница 37: ... 01 64 Zone number 1 99 Any zone number 30 Cold start PGM 01 08 Output number 1 99 Any output number 31 Cold start keypad 01 04 Keypad number 1 99 Any keypad number 32 Cold start repeater 01 04 Repeater number 1 99 Any repeater number 33 Cold start siren 01 04 Siren number 1 99 Any siren number Table 12 Reportable Events Saved Events Event Event Description Sub event Sub event Description Area 40 ...

Страница 38: ... 64 Zone number 1 2 3 99 Any zone number 52 Special alarm 00 Panic emergency 1 2 3 01 Panic medical 1 2 3 02 Panic fire 1 2 3 03 Recent closing 1 2 3 04 Global shutdown 1 2 3 05 Duress alarm 1 2 3 06 Keypad lockout 53 Paramedic alarm 01 16 User number 1 2 3 99 Any user number 54 Special 00 System power up 1 01 Reporting test 02 Software log on 03 Software log out 04 Installer in programming mode 0...

Страница 39: ...PGM tamper trouble 01 08 PGM number 1 99 Any PGM number 64 PGM tamper trouble restore 01 08 PGM number 1 99 Any PGM number 65 PGM supervision loss 01 08 PGM number 1 99 Any PGM number 66 PGM supervene loss restore 01 08 PGM number 1 99 Any PGM number 67 Keypad supervision loss 01 04 Keypad number 1 99 Any keypad number 68 Keypad supervision loss restore 01 04 Keypad number 1 99 Any keypad number 6...

Страница 40: ... 83 Siren low battery 01 04 Siren number 1 99 Any siren number 84 Siren low battery restore 01 04 Siren number 1 99 Any siren number 85 Siren AC trouble 01 04 Siren number 1 99 Any siren number 86 Siren AC trouble restore 01 04 Siren number 1 99 Any siren number Table 13 List of alphanumeric key inputs Key Value or Action Key Value or Action 1 1 special characters _ 0 0 2 A B C 2 Inserts a space 3...

Страница 41: ...MG6250 Section Programming Guide Version 1 6 Entering Information 41 Special Characters V1 0 only To enter a special character press the SLEEP key followed by the character s corresponding number ...

Страница 42: ...G6250 Section Programming Guide Special Characters V1 2 and up To enter a special character press the SLEEP key followed by the character s corresponding three digit number Figure 1 Polish Hungarian Czech Croatian Romanian Slovak Slovenian ...

Страница 43: ...MG6250 Section Programming Guide Version 1 6 Entering Information 43 Figure 2 Russian Bulgarian Serbian ...

Страница 44: ...Version 1 6 44 Entering Information MG6250 Section Programming Guide Figure 3 English French Spanish Italian Swedish Portuguese German Dutch Malay Finnish French Canadian Belgian ...

Страница 45: ...MG6250 Section Programming Guide Version 1 6 Entering Information 45 Figure 4 Greek ...

Страница 46: ...Version 1 6 46 Entering Information MG6250 Section Programming Guide Figure 5 Turkish ...

Страница 47: ...MG6250 Section Programming Guide Version 1 6 Entering Information 47 Figure 6 Hebrew ...

Страница 48: ...Version 1 6 48 Entering Information MG6250 Section Programming Guide Figure 7 Lithuanian Estonian Latvian ...

Страница 49: ...the DC Power Supply Backup Battery Pack The MG6250 uses a backup battery pack to provide power during a power loss A 4 8V 1200mAH NiMH Nickel Metal Hydride rechargeable battery pack is included with the console Connect the battery pack as shown in figure 10 Figure 10 Connecting the Backup Battery To order a battery pack the battery pack s part number is Paradox 0781200148 NOTE The backup battery c...

Страница 50: ...t be employed to power the circuit If the current draw on the PGMs is to exceed 50mA we recommend using an external relay as shown in Method 2 in figure 12 For connecting the PGM2 see figure 13 NOTE Using Method 2 connect the device to the output terminal of the external relay that matches the normal state of the MG6250 s PGM output Keep in mind that the maximum voltage of PGM1 and PGM2 is 12Vdc F...

Страница 51: ...g After connecting the detection devices the zones must be defined See Zone Programming on page 6 for more information The hardwire zones follow the console s EOL and tamper definitions NOTE Though any hardwire detection device can be connected to the MG6250 s on board hardwire zone inputs it is recommended that only devices that do not require a power source i e standard door contacts be connecte...

Страница 52: ...e trouble warning except AC power failure Disabled Enabled 3 AC power failure warning Disabled Enabled 4 Lock master code Disabled Enabled 5 Console tamper supervision Disabled Enabled 6 Code necessary to bypass zones Disabled Enabled 7 Partition Disabled Enabled 8 Future use Section Option Description OFF ON 2002 1 Volume boost on entry exit Disabled Enabled 2 Volume boost in speaker phone mode D...

Страница 53: ...low zone s alarm type ON OFF Disarmed Audible alarm Armed Follow zone s alarm type ON ON 8 Generate supervision trouble if detected on bypassed zone Disabled Enabled Section Option Description OFF ON 2009 1 Restrict Arming when zone opens during exit delay Disabled Enabled 2 Acknowledge Trouble s before Arming Disabled Enabled 3 Future Use 4 Future Use 5 Future Use 6 Future Use 7 GSM Antenna Inter...

Страница 54: ... F Humidity range 5 to 90 GPRS14 specs Quad band GPRS GSM module with two SIM cards Interconnection types TIP Ring T1 R1 I 02 I O1 C battery Current consumption Standby 150mA maximum 1A Prioritisation of signal and message processing and indications 1 Alarm 2 Trouble 3 System Status User code details All numbers for 0000 to 9999 are valid giving a total of 10 000 possible combinations EN50131 comp...

Страница 55: ...nd conditions Patents One or more of the following US patents may apply 7046142 6215399 6111256 6104319 5920259 5886632 5721542 5287111 and RE39406 Canadian and international patents may also apply 2014 Paradox Ltd All rights reserved Specifications may change without prior notice Magellan and BabyWare are trademarks or registered trademarks of Paradox Ltd or its affiliates in Canada the United St...

Страница 56: ...e Canada and the U S call 00 1 450 491 7444 Monday to Friday from 8 00 A M to 8 00 P M EST The whole Paradox team wishes you a successful and easy installation We hope this product performs to your complete satisfaction Should you have any questions or comments please visit www paradox com Printed in Canada 07 2014 PARADOX COM MG6250 EP04 ...

Отзывы: