background image

Paradox Magellan Systems

 

35

CID#

Reporting Code

Programming 
Value

335

Local printer paper out

54

336

Local printer failure

55

337

Expansion module DC loss

56

338

Expansion module low battery

57

339

Expansion module reset

58

341

Expansion module tamper

59

342

Expansion module AC loss

5A

343

Expansion module self-test fail

5B

344

RF receiver jam detect

5C

Communication Troubles - 350 and 360

350

Communication

5D

351

Telco 1 fault

5E

352

Telco 2 fault

5F

353

Long range radio

60

354

Fail to communicate

61

355

Loss of radio supervision

62

356

Loss of central polling

63

357

Long range radio VSWR problem

64

Protection Loop Troubles - 370

370

Protection loop

65

371

Protection loop open

66

372

Protection loop short

67

373

Fire trouble

68

374

Exit error alarm

69

375

Panic zone trouble

6A

376

Hold-up zone trouble

6B

377

Swinger trouble

6C

378

Cross-zone trouble

6D

Sensor Troubles - 380 and 390

380

Sensor trouble

6E

381

Loss of supervision - RF

6F

382

Loss of supervision - RPM

70

383

Sensor tamper

71

384

RF transmitter low battery

72

385

Smoke detector Hi sensitivity

73

386

Smoke detector Low sensitivity

74

387

Intrusion detector Hi sensitivity

75

388

Intrusion detector Low sensitivity

76

389

Sensor self-test failure

77

391

Sensor watch trouble

78

392

Drift compensation error

79

393

Maintenance alert

7A

Open/Close - 400

400

Open/Close

7B

401

Open/Close by user

7C

402

Group open/close

7D

403

Automatic open/close

7E

406

Cancel

7F

407

Remote arm/disarm

80

CID#

Reporting Code

Programming 
Value

408

Quick arm

81

409

Keyswitch open/close

82

Remote Access - 410

411

Call back request made

83

412

Success - download access

84

413

Unsuccessful access

85

414

System shutdown

86

415

Dialer shutdown

87

416

Successful upload

88

Access Control - 420 and 430

421

Access denied

89

422

Access report by user

8A

423

Forced access

8B

424

Egress denied

8C

425

Egress granted

8D

426

Access door propped open

8E

427

Access point door status monitor trouble

8F

428

Access point request to exit

90

429

Access program mode entry

91

430

Access program mode exit

92

431

Access threat level change

93

432

Access relay/trigger fail

94

433

Access RTE shunt

95

434

Access DSM shunt

96

Arming - 440 and 450

441

Armed Stay

97

442

Keyswitch armed Stay

98

450

Exception open/close

99

451

Early open/close

9A

452

Late open/close

9B

453

Failed to open

9C

454

Failed to close

9D

455

Auto-arm failed

9E

456

Partial arm

9F

457

Exit error (user)

A0

458

User on premises

A1

459

Recent close

A2

System - 460

461

Wrong code entry

A3

462

Legal code entry

A4

463

Re-arm after alarm

A5

464

Auto-arm time extended

A6

465

Panic alarm reset

A7

466

Service on/off premises

A8

Sounder Relay Disabled - 520

520

Sounder/Relay disabled

A9

521

Bell 1 disabled

AA

522

Bell 2 disabled

AB

523

Alarm relay disabled

AC

524

Trouble relay disabled

AD

Содержание MG-6060

Страница 1: ...All In One Wireless Security System V1 0 Model MG 6060 Reference and Installation Manual...

Страница 2: ......

Страница 3: ...es to Stay Arming 20 Regular Arming Switches to Force Arming 20 Stay Arming Switches to Force Arming 20 Timed Auto Arming 20 No Movement Auto Arming 20 Auto Arming Options 20 One Touch Arming 21 Exit...

Страница 4: ...2 Reference Installation Manual Panel Answer Options 33 Panel Identifier 33 PC Password 33 PC Telephone Number 33 Call Back Feature 33 Appendix 1 Ademco Contact ID Report Code List 34 Index 37...

Страница 5: ...you read this entire manual before you begin installation Conventions Specifications Power input AC 9Vac 1A 9VA transformer or 16 5Vac 20VA transformer or DC 12Vdc to 18Vdc power supply Current consu...

Страница 6: ...immediately access the Zone Profile menu For more in depth programming of the console s communication features see Reporting and Dialer Settings on page 24 4 Adding and Programming Zones 1 From the Zo...

Страница 7: ...y 2 Press NEXT until you reach the Time and Date menu and press OK or press the 3 key to access the Time and Date menu 3 Select the time format 12Hr clock or 24Hr clock and then program the time Press...

Страница 8: ...to a telephone line by connecting the telephone company s wires directly to Magellan s dialer or by connecting a standard 4 pin RJ 11 cable between the LINE plug of the console to a standard telephone...

Страница 9: ...lug Connection Programmable Outputs PGMs Magellan comes equipped with two 50mA solid state PGM outputs When a specific event occurs in the system a PGM can be programmed to activate lights garage door...

Страница 10: ...Software for Windows WinLoad allows for remote or on site uploading and downloading using most standard modems It also allows for advanced printing of reports and supports several languages simultaneo...

Страница 11: ...lation near or in the path of strong RF fields i e neon lights computers and on or near metal objects circuit breakers boxes air conditioners and heater ducts since they may cause interference and red...

Страница 12: ...with Magellan are two plastic feet as well as two rubber stops The plastic feet raise the Magellan console to a slight angle for easy viewing while the rubber stops prevent the console from sliding wh...

Страница 13: ...ection s options are set When the options are set press the key to save and advance to the next section Press the key twice to exit without changing any data Programming Using a Paradox Memory Key The...

Страница 14: ...to program all features options and commands except for the console s communication settings sections 100 to 154 as well as any user code The Maintenance code can be 4 or 6 digits in length see User C...

Страница 15: ...16 3 digit 002 Entry Delay 2 zones are identical to the Entry Delay 1 zones see Entry Delay 1 on page 13 except it uses a separate Entry Delay Timer Entry Delay 2 Timer Section 061 001 to 255 seconds...

Страница 16: ...d bell siren output signal as shown in Figure 17 on page 14 Figure 17 Bell Siren Output during a Fire Alarm Delayed Fire Zones Sections 001 to 016 Zones 1 to 16 3 digit 008 When a Delayed 24Hr Fire Zo...

Страница 17: ...Option 2 OFF Bypass option disabled Option 2 ON Selected zone is bypass enabled default When a user uses the Bypass Programming feature only zones with the Bypass option enabled can be programmed as b...

Страница 18: ...breached Fire zones cannot be programmed with the Force Zone option because the console will not bypass a Fire zone when the system is being Force armed Stay Delay Zones Section 094 Options 1 Option 1...

Страница 19: ...e pushbutton is pressed Magellan will in turn become a doorbell and play a predetermined tone see Wireless Doorbell Tones on page 17 Please refer to the appropriate Magellan Wireless Door Contact Inst...

Страница 20: ...rogrammed to perform up to 5 different actions Each digit in sections 161 to 176 represents a button or combination of buttons see Table 4 on page 18 To program a remote control s buttons 1 Access the...

Страница 21: ...de 5 Future use D Turn FM radio ON OFF 6 Future use E FM radio memory scan 7 Future use F Paramedic alarm Inset 1 Removing the Battery Inset 2 Inserting the New Battery Step 1 Step 2 WARNING Damage to...

Страница 22: ...g report code programmed in section 124 Example To automatically arm the system everyday at 6 15PM enable section 092 option 1 to activate Timed Auto arming and then key in 18 15 into section 085 Auto...

Страница 23: ...the system is armed with a remote control Exit Delay Termination Section 093 Option 6 Option 6 OFF Exit delay termination feature disabled Option 6 ON Exit delay termination feature enabled default Wh...

Страница 24: ...ypassed zone When option 5 is OFF the Tamper Recognition feature page 22 will follow the zone s bypass definition This means the console will ignore any tampers that occur on a bypassed zone Check in...

Страница 25: ...econds See Table 7 on page 23 for the appropriate panic alarm keys Whether these panic alarms will generate a silent or audible alarm is determined by section 091 options 4 to 6 see Panic Alarm Types...

Страница 26: ...s Section 125 One touch Arming The system was armed using a One touch Arming feature see page 21 Remote Arming The system was armed using the WinLoad software Future use Future use Disarming Report Co...

Страница 27: ...d or battery voltage is d less than or equal to 6 9V Timer Loss The console has detected a loss in time or clock failure Section 150 Future use Fail To Communicate The Magellan console has failed all...

Страница 28: ...e Installer menu Refer to the Magellan Quick Setup Guide for more information to play a pre recorded message to an external telephone or cellular telephone Please note the following when programming a...

Страница 29: ...ndard messages and report codes Event Call Direction Section 100 Options 1 to 3 Arming Disarming Option 1 ON Call CSTN 1 Option 2 ON Call CSTN 2 Option 3 ON Call Pager telephone number Section 100 Opt...

Страница 30: ...an console switches from tone DTMF dialing to pulse dialing on the fifth attempt to report events to the Central Monitoring Station The console continues to use pulse dialing until it establishes comm...

Страница 31: ...tion 149 after the Power Failure Report Delay period has elapsed Disarm Reporting Options Section 093 Option 5 Option 5 OFF Always Report Disarming Option 5 ON Report Disarming only after Alarm Defaul...

Страница 32: ...programmed period elapses see PGM Delay on page 30 If using the PGM Delay sections 087 and 089 can be used as a second PGM Activation Event For the Event List see the PGM Table in the Magellan Program...

Страница 33: ...ngs Time Section 096 Option 5 Option 5 OFF Daylight savings time disabled default Option 5 ON Daylight savings time enabled With section 096 option 5 ON Magellan adjusts the system s clock time for da...

Страница 34: ...lan console has failed to contact the monitoring station Fail to Communicate with Voice Reporting The Magellan console has failed to contact telephone number programmed for Voice reporting Fail to Com...

Страница 35: ...le will answer the call You must wait at least 10 seconds before attempting the second call or Magellan will think it is the same call Panel Identifier Section 108 4 digit Hexa decimal number from 000...

Страница 36: ...rigeration 27 153 Loss of heat 28 CID Reporting Code Programming Value 154 Water leakage 29 155 Foil break 2A 156 Day trouble 2B 157 Low bottled gas level 2C 158 High temperature 2D 159 Low temperatur...

Страница 37: ...nance alert 7A Open Close 400 400 Open Close 7B 401 Open Close by user 7C 402 Group open close 7D 403 Automatic open close 7E 406 Cancel 7F 407 Remote arm disarm 80 CID Reporting Code Programming Valu...

Страница 38: ...trigger test BD 602 Periodic test report BE 603 Periodic RF transmission BF 604 Fire test C0 605 Status report to follow C1 606 Listen in to follow C2 607 Walk test mode C3 608 Periodic test system t...

Страница 39: ...131 to 134 24 135 to 138 24 139 24 140 12 24 25 141 to 144 25 145 to 148 25 149 25 150 25 151 25 153 25 154 12 25 155 25 156 25 161 to 176 18 180 31 181 12 182 12 187 14 190 14 200 12 201 31 24Hr zon...

Страница 40: ...Key 9 10 PGMs 7 Telephone Line 6 UIP 256 8 WinLoad 8 X10 9 Console account number 26 Console audible trouble warning 31 Console tamper supervision 31 Console telephone numbers 25 Contact ID 27 Cut of...

Страница 41: ...rings 33 O Options zone Alarm types 15 Auto zone Shutdown 15 Bypass option 15 Delay before Alarm Report Code Transmission 16 Force Zones 16 Intellizone 15 Overview zone programming 13 P Pack backup ba...

Страница 42: ...es Follow Stay Zones 14 Instant Stay Zones 14 Supervision Check in 22 Console tamper 31 Wireless transmitters 22 Supervision Bypass options 22 Switch to Pulse dialing 28 System master code 12 System m...

Страница 43: ...come hardwire 16 Wirless doorbell tones 17 X X10 connections 9 X10 PGM option 30 Z Zone alarm report codes 24 Zone alarm restore report codes 24 Zone definitions 24Hr Burglary Zones 14 24Hr Buzzer Zon...

Страница 44: ...42 Reference Installation Manual...

Страница 45: ...ediate disconnection of terminal equipment Standard jacks shall be so arranged that if plug connected thereto is withdrawn no interference to operation of equipment at customer s premises which remain...

Страница 46: ......

Страница 47: ......

Страница 48: ...780 Industriel Blvd Saint Eustache Quebec J7R 5V3 CANADA Tel 450 491 7444 Fax 450 491 7313 www paradox ca Printed in Canada 09 2004 MAGELLAN EI01...

Отзывы: