To start the procedure select Soot test in the Operation screen and follow the
steps presented below:
1. Put the soot test filter into the probe holder's slot.
2. Set the pointer on the Pump regulation and press
Start
function key
Drawing 25.
Screen of flow setting for soot measurements
3. Observe the flow meter, set the flow value to 100 l/h by regulating the pump
efficiency using function keys
(+)
,
(-)
.
4. When the flow is set, press the
Stop
function key and set the pointer at the
Soot test.
5. Put the clean paper filter into the hose's holder and start measurement by
pressing Start function key.
6. To confirm the measurement choose
Yes
, to cancel choose
Esc
.
Drawing 26.
Screen of confirmation of Soot measurement