MadgeTech UltraShock Скачать руководство пользователя страница 3

 Product User Guide  |  3

UltraShock

LED Indicator Functions

The red and green LEDs on the front of the UltraShock will flash or 
maintain a static condition to represent operating functions as shown  
in the table below.
The power up indication is only presented if the battery pack is separated 
from the front face and replaced. This should be done only during factory 
service or if directed to do so by a MadgeTech support or repair agent. If  
it is presented at any other time, there may be a malfunction of the unit.

PRODUCT OVERVIEW

Red LED 

Indicator

Green LED 

Indicator

OPERATING FUNCTION

GREEN LED INDICATOR

RED LED INDICATOR

Power-up Indicator

Flashes 4 times

 

Red and green LED indicators alternately and rapidly flash 4 times each at power-up. LED indicators 

continue to flash for error at power-up.

Logging Data  

(without USB connected)

Flashes every 15 seconds

 

Indicates normal operation of logger without USB 

connected and adequate battery charge level.

Flashes every 15 seconds (maximum)

 

Indicates low battery charge level.

Logging Data 

(with USB communication)

Flashes every 15 seconds

 

Indicates normal operation of logger with USB 

connected.

Flashes every 5 seconds (maximum)

 

Indicates when logger communication occurs via 

USB.

Delayed Logging Start

Flashes every 3 seconds 

Red and green LED indicators simultaneously flash every 3 seconds to indicate data logging delayed start is 

set.

USB Charging 

(USB connected)

Pulses slowly on and off

 

Indicates when battery is charging via USB 

connector.

Flashes every 5 seconds (maximum)

 

Indicates when logger communication occurs via 

USB.

Battery Charged 

(USB connected)

On

 

Indicates when battery is fully charged when 

connected to USB.

Flashes every 5 seconds (maximum)

 

Indicates when logger communication occurs via 

USB.

Battery Charging Fault 

(USB connected)

Off

 

On 2 seconds then off 2 seconds

 

Indicates when there is a battery charging fault and 

continues to flash until fault is cleared.

Logger Off

Off 

Red and green LED indicators are off when logger is off and USB not connected.

Содержание UltraShock

Страница 1: ...ck Data Logger PRODUCT USER GUIDE TABLE OF CONTENTS 2 Product Overview 4 Software Installation Guide 5 Device Operation 8 Product Maintenance 9 Specifications 10 Dimensional Drawings To view the full...

Страница 2: ...occur when the UltraShock is mounted by two bolts directly to a solid metal flat surfaced object of significant mass For various applications the rigid bolted down mounting may not be optimal or prac...

Страница 3: ...SB connected and adequate battery charge level Flashes every 15 seconds maximum Indicates low battery charge level Logging Data with USB communication Flashes every 15 seconds Indicates normal operati...

Страница 4: ...ts before other parameters Pressure The UltraShock pressure sensor is designed to measure barometric pressure from very low altitudes to those altitudes found in aircraft up to high altitude balloons...

Страница 5: ...pending upon your start method 6 Disconnect the data logger from the interface cable and place it in the environment to measure Note The device will stop recording data when the end of memory is reach...

Страница 6: ...s will only sample data at the logging rate For instance if a 30 second logging rate was selected then only a single data point is captured at each 30 second instant The potential to lose valuable dat...

Страница 7: ...100 samples are acquired at the selected logging rate The trigger sample count should be chosen carefully because it may gather data points for which we have no interest For instance if 100 were enter...

Страница 8: ...cell pack Please note the safe handling and storage recommendations in the specifications section Inspection The UltraShock may be inspected visually for any signs of damage especially to the gray gas...

Страница 9: ...nto the device to restrict access to configuration options Data may be read out with the password Calibration Digital calibration through software Calibration Date Automatically recorded within device...

Страница 10: ...21 8 mm 1 72 43 7 mm 0 20 5 1 mm 2X 0 20 5 1 mm THRU 4X R0 25 R6 4 mm APPLIQUE COVER GASKET BATTERY PACK RH AND PRESSURE SENSOR PORT TYPE C USB CONNECTOR 3 00 76 2 mm RED LED INDICATOR GREEN LED INDIC...

Отзывы: