Device Configuration Menu

Displays options available within the device configuration menu 

 

 

 

 

F1

 = DISPLAY: enters Adjust Visibility screen 

F2

 = POWER: enters Power Modes screen 

F3

 = INFO: goes to Device Information screens 

F4

 = EXIT: returns to main screen

 

CANCEL

 = returns to main screen  

OK

 = returns to main screen 

UP

 = no function 

Down

 = no function 

Device Reset

This device include two reset options, Hardware and Power Interruption

 

 

 

Power Interruption:

 

isplayed as notification when power is interrupted during device operation.

 

F1

 = OK: accepts notification and displays main screen 

F2

 = no function 

F3

 = no function 

F4

 = no function 

CANCEL

 = no function 

OK

 = accepts notification and displays main screen 

UP

 = no function 

DOWN

 = no function

Hardware Reset:

 

Displayed as notification when a hardware reset has occurred.

F1

 = OK: accepts notification and displays main screen

F2

 = no function

F3

 = no function

F4

 = no function

CANCEL

 = no function

OK

 = accepts notification and displays main screen

UP

 = no function

DOWN

 = no function

Содержание pHTemp2000

Страница 1: ...pHTemp2000 Red 485 Dark Blue Pantone 289 Light Blue 58 of Pantone 289 pHTemp2000 pH and Temperature Data Logger with LCD Product User Guide...

Страница 2: ...oftware Installation 5 Device Operation 5 6 Computer Interface 6 Front Panel Overview 7 Screen Descriptions 8 9 Device Maintenance 10 General Specifications 11 Table of Contents To view the full Madge...

Страница 3: ...n recognized 5 Select the start method reading rate and any other parameters appropriate for the desired data logging application Once configured click the Start icon and deploy the data logger 6 To d...

Страница 4: ...s Delay start Wait Icon device is busy Device reset has occurred External power present Product Overview The pHTemp2000 is a pH and temperature data logger with LCD display The convenient LCD provides...

Страница 5: ...or an appropriate adapter Select a probe with an output impedance less than 300 megaohms at the desired tem perature 2 The temperature probe must be a 100 platinum RTD in the standard 2 3 or 4 wire co...

Страница 6: ...rt method 6 Disconnect the data logger from the interface cable and place it in the environment to measure Note The device will stop recording data when the end of memory is reached or the device is s...

Страница 7: ...d F2 to the pH probe Pressing these function keys will cause the channels to scroll between show or hide channels displaying show will appear on the main screen and channels displaying hide will not A...

Страница 8: ...and Time Statistics Statistics Menu Screen Displays options available within the statistics menu pH Channel Statistics Displays pH statistics Type Statistics Displays statistics from pH statistics Te...

Страница 9: ...ardware and Power Interruption Power Interruption isplayed as notification when power is interrupted during device operation F1 OK accepts notification and displays main screen F2 no function F3 no fu...

Страница 10: ...ww madgetech com Battery Information Materials 3 32 HEX Driver Allen Key and a Replacement Battery U9VL J Remove the back cover from the device by unscrewing the four screws Remove the battery from it...

Страница 11: ...145 40 C to 110 C 40 F to 230 F Temperature Resolution 0 001 0 01 C 0 018 F Calibrated Accuracy 0 015 0 04 C 0 072 F Memory 131 071 channel Reading Rate 1 reading every 2 seconds up to 1 reading every...

Страница 12: ...MadgeTech Inc 6 Warner Road l Warner NH 03278 Phone 603 456 2011 l Fax 603 456 2012 madgetech com l info madgetech com DOC 1176036 00 REV 12 2019 02 01...

Отзывы: