1. Keep the Aroma Diffuser in a clear space to allow the mist to freely spread and 

away from appliances especially those sensitive to water to avoid unnecessary 

accidents.

2. Place the Aroma Diffuser on a flat surface, at least 60 cm away from the floor and 

at least 10 cm away from the wall. DO NOT place the Aroma Diffuser on wooden or 

polished furniture that may be damaged by water moisture.

3. Always unplug the Aroma Diffuser from the mains electrical supply when cleaning 

or filling with water. Always use the power adaptor supplied. Ensure the cable is 

secure to avoid tripping or knocking over the Aroma Diffuser. If the power adaptor 

is damaged, it must be replaced with a suitable adaptor provided by the 

manufacturer or its agent. Alternatively, a new adaptor can be purchased from your 

retailer.

4. Use a suitable measuring cup to fill the water into the water tank. Never attempt 

to fill water under a running tap or whilst plugged in. Do not fill the water beyond 

the Max water level line. If overfilled, carefully remove the excess water from the 

water tank, ensure that water does not enter the air vent hole. 

5. The Aroma Diffuser must be kept out of reach from children and pets to avoid 

risk of injury. Children should be supervised at all times to ensure they do not play 

with the appliance or touch the Himalayan Salt crystals (which may become hot). 

6. The Himalayan Salts are not for consumption. 

7. The Aroma Diffuser is not intended for use by persons (including children) with 

reduced physical, sensory or mental capabilities or lack of experience and 

knowledge, unless they have been given supervision or instruction concerning use 

of the appliance by a person responsible for their safety.

8. The Aroma Diffuser must be cleaned after each use and should always be kept 

clean and dry when not in use. Never leave stagnant oil and water in the tank for 

prolonged periods.

9. The Himalayan Salt crystals should be removed and stored into a sealed plastic 

bag, when not being used for long periods of time. This will prolong the life of the 

salt crystals.  

10. Never attempt to disassemble or repair the product as this may void your 

warranty and create a shock hazard. Contact your retailer if your Aroma Diffuser 

develops a fault.

11. In case of any abnormal observations such as smoke, peculiar smells or noise, 

stop using the device immediately and contact your retailer from where you 

purchased the Aroma Diffuser. Never wrap the adaptor or diffuser with cloth or 

paper, as blocking the ventilation could increase the fire risk.

12. Always handle the Aroma Diffuser with care - accidental damage is not covered 

under the warranty.

13. Always use water at room temperature and only use fresh, clean water from a 

reliable source. Do not fill the water tank with other chemicals or liquids other than 

water and a few drops of essential or fragrance oils.

14. Always plug the DC jack into the DC socket on the diffuser before plugging the 

adaptor into the mains.

15. Do not remove the covers during operation.

16. NEVER touch the ultrasonic ceramic disc while the diffuser is plugged in as this 

could cause serious injury.

Do not touch the Himalayan salt crystals during normal operation as they may 

become hot. 

17. Do not immerse the unit in water or other liquids and do not attempt to clean in 

a dishwasher.

18. The Aroma Diffuser needs to be topped up with water to operate. The 

Himalayan Salt Lamp can be used independently to the aroma diffuser. 

19. DO NOT touch the bulb or central part of the unit when the unit is powered or 

when the lamp is still hot.

20. Unplug adaptor when you replace the bulb. Keep your hands clean and dry 

when you replace the bulb. Make sure bulb is clean after it is installed.

21. Keep water away from the Contact Point. If any water accidentally spills onto the 

Contact Point, carefully remove with a dry tissue.

Содержание GLO EW9630

Страница 1: ...GLO Aroma Diffuser and Himalayan Salt Lamp Create a relaxing ambience with a warm crystalline glow and cool scented mist...

Страница 2: ...Diffuser Himalayan Salt Lamp Please keep this manual to help you get the most out of your Glo and for maintenance TABLE OF CONTENTS A ABOUT THE GLO B TECHNICAL SPECIFICATION C OPERATING INSTRUCTIONS...

Страница 3: ...ocks create a wonderfully soothing pink glow that can promote deep relaxation and boost your mood Using state of the art technology and modern design Glo will add a touch of luxury to any home Adding...

Страница 4: ...eight without salt crystals 2 1KG Coverage Area 15 Bulb G4 halogen lamp 24V 10W AC DC adaptor Input 100 240V 50 60Hz Output DC24V 750mA TECHNICAL SPECIFICATIONS A Outer Cover B Inner Cover C Water Tan...

Страница 5: ...Do not fill the water beyond the Max water level line If overfilled carefully remove the excess water from the water tank ensure that water does not enter the air vent hole 5 The Aroma Diffuser must b...

Страница 6: ...oils 14 Always plug the DC jack into the DC socket on the diffuser before plugging the adaptor into the mains 15 Do not remove the covers during operation 16 NEVER touch the ultrasonic ceramic disc w...

Страница 7: ...rect direction The MAX mark inside the water tank should be to the rear of the diffuser and ensure the Contact Point is securely connected OPERATING INSTRUCTIONS Setting Up Your Diffuser 2 Plug bulb p...

Страница 8: ...ter beyond the MAX level mark The diffuser will not work if filled beyond the MAX level mark 4 Then add 3 5 drops of your favourite fragrance or essential oil madebyzen oils recommended OPERATING INST...

Страница 9: ...7 Connect the DC jack into the diffuser then plug the adaptor to the mains power supply 8 Switch the unit on see Settings on next page 6 Replace the Outer Cover 5 Replace the Inner Cover...

Страница 10: ...p operates independently to the Aroma Diffuser function There are 5 levels of light intensity at each touch Touch the button repeatedly to increase the lamp intensity of the Himalayan salt lamp The si...

Страница 11: ...oundings The Himalayan Salt Lamp uses a low energy halogen bulb to create a warm glow to the salt crystals creating a relaxing ambience to your living space Small amounts of minerals contained within...

Страница 12: ...before cleaning Always keep your Aroma Diffuser clean and dry when not in use Never leave stagnant oil and water inside the water tank for prolonged periods If the aroma diffuser stops generating mis...

Страница 13: ...Then lift off the outer cover inner cover and water tank IMPORTANT INSTRUCTIONS RECOMMENDED AFTER EACH USE 2 Drain and rinse the water tank away from the vent hole and clean thoroughly to remove any...

Страница 14: ...d properly Solution Align the water tank correctly to the Contact Point and check there is no water on the contacts Refill the tank with ordinary tap water Take care not to fill past the Max water lev...

Страница 15: ...has been tipped or knocked over The temperature is low or there is high humidity The light is intermittent The light does not come on Remove the cover and replace correctly to allow the mist to flow...

Страница 16: ...retailer for maintenance or claims Proof of purchase will be required so it is vital that you keep your receipt of purchase safely with this manual Corrosive oils such as Citronella may cause damage t...