Made NADIR Скачать руководство пользователя страница 14

 

GU_NADIR_V_3_20_EN 

14 / 20 

 

7  NADIR OPERATION 

 

 

CABLE PRE-IDENTIFICATION " function : 

 

There are two options : 
 

 

The remote Transducer is placed on the cable 

 

Or just the Receiver, using the internal Transducer

 
The measurement is carried out at the point of interest. Since the conductors are twisted in the cable, 
and  the  modulation  is  between  one  phase  and  neutral  or  between  2  phases,  move  the  Transducer 
along or around the cable to seek the best signal. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
This  operation  is  first  done  in  SEARCH  mode,  which  gives  an  instantaneous  measurement 
(acquisition time 

 2 seconds). During the acquisition, hold the transducer still. 

 
When  a  significant  signal  is  found,  change  to  IDENTIFICATION  mode,  which  gives  a  measurement 
integrated over 5 seconds. 
 
As  an  indication,  drawing  on  our  experience,  the  minimum  values  found  on  the  correct  cable  are 
around 35 to 40 % (according to the network and it’s load). 
In ideal circumstances, the received level is from 70 % to 90 %
 
On the "

wrong

" cables or phases, the signal is < 10 %

 
 

3 Cables in the trench 

 
 
 
 

 

 

 

 

 

 

 

 

 1 m 

Measurement         Measurement           Measurement 
          1                              2                                3 
                      with the NADIR Receiver 

Содержание NADIR

Страница 1: ...NADIR USER S GUIDE September 2009 MADE V 3 20...

Страница 2: ...MITTER 7 4 1 CONNECTION OF THE TRANSMITTER 8 5 NADIR RECEIVER 9 6 USING NADIR RECEIVER 10 6 1 USING THE INTERNAL TRANSDUCER 12 6 2 USING THE EXTERNAL TRANSDUCER 12 6 3 USING THE MADE FLEX ROGOWSKI COI...

Страница 3: ...ely to personnel qualified by MADE 1 2 Following the safety recommendations DANGER Indicates a dangerous or potentially dangerous situation which if not avoided could cause serious or deadly injuries...

Страница 4: ...ironments It is incumbent upon those who install these systems in dangerous environments to determine the acceptability of the system for its environment Additionally to guarantee safety the installat...

Страница 5: ...for the connected loads This signal will be found between the Transmitter connection point and the power source i e Substation This signal is analysed digitally in the Receiver which enables the user...

Страница 6: ...isplay screen and integral cable transducer Remote transducer for cable pre identification MADE Flex Rogowski coil for locating the phase s The charger for Receiver battery pack is integrated into the...

Страница 7: ...pply 230 V or 400 V The Transmitter is started by switching it ON and a flashing green LED indicates correct operation In the presence of an internal fault the red FAULT lamp will light Should this oc...

Страница 8: ...GU_NADIR_V_3_20_EN 8 20 4 1 Connection of the Transmitter Phase to Phase connection in a link box Phase to Neutral connection in a link box...

Страница 9: ...grated battery pack This reading will only be correct when the Receiver is disconnected from the charger and the charging cable To recharge the battery pack connect the link cable to the charger in th...

Страница 10: ...find the highest signal To use with the integral Transducer Do not connect a Transducer to the Receiver Place the back of the Receiver on the cable and proceed as above Menu Press VALID to enter the c...

Страница 11: ...for a more precise discrimination between cables and phases The measurement is made with more sophisticated algorithms in order to better identify the transmitted signal and integrated over 5 seconds...

Страница 12: ...GU_NADIR_V_3_20_EN 12 20 6 1 Using the internal Transducer Correct Position Wrong Position 6 2 Using the external Transducer...

Страница 13: ...GU_NADIR_V_3_20_EN 13 20 6 3 Using the MADE FLEX Rogowski coil to identify a phase Rogowski coil...

Страница 14: ...signal This operation is first done in SEARCH mode which gives an instantaneous measurement acquisition time 2 seconds During the acquisition hold the transducer still When a significant signal is fou...

Страница 15: ...e MADE FLEX coil The menus SEARCH or IDENTIFICATION are used as above As an indication the minimum levels observed should be between 30 and 100 depending on the network and loads On the wrong cables t...

Страница 16: ...sumption 4 A Fuse on the front face of the Transmitter power 10 AHPC Charger 200 mA Crocodile clip with 10 AHPC fuses Range of voltage 185 V to 250 V or 350 V to 420 V Receiver supply Internal battery...

Страница 17: ...faces Use only the accessories delivered with the system In the event of a technical problem request assistance from MADE SA Tel 33 494 083 198 or A T M S Tel 07 717 763 510 or Norwich Instruments Ser...

Страница 18: ...MADE Any product that is not used in accordance with the instructions provided by MADE Cost of transport back to MADE Cost of transport by express delivery of parts or products under guarantee Cost t...

Страница 19: ...munication of its content are forbidden without written authorization of MADE The content of this document is destined for use only as information It can be modified without prior notice and must not...

Страница 20: ...336 CEE Low Voltage Directive LVD Electromagnetic Compatibility Directive EMC and that the standards and or technical specifications listed in this manual have been applied The designated product has...

Отзывы: