background image

4

1.2  Restrictions

PROHIBITED

–  Modify and/or attempt to repair the 

product. All repairs must be per-

formed exclusively by authorised 

personnel.

–  Leave the device exposed to atmos-

pheric agents.

–  Place the device near to heat sourc-

es or expose it to direct sunlight.

–  Install the device near other electri-

cal equipment as this may lead to 

signal disturbance.

–  Open and/or replace the battery.
–  Use solvents to clean the device.
–  Incorrectly dispose of packaging 

material and keep it out of chil-

dren’s reach as it may represent 

a hazard. Disposal must be per-

formed in line with applicable laws.

–  Dispose of the device as domestic 

waste.

1.3  Device description

Arrow

WAN

 is a radio module with pulse input 

compatible with 

Maddalena water meters 

and with those of other brands. The device 

allows for measuring, transmitting and re-

motely reading the consumption values and 

the alarms using a wireless transmission 

technology.

Arrow

WAN

  is  available  in  two  versions:           

Arrow

WAN

 

169 and Arrow

WAN

 

868. The two 

versions  differ  for  their  transmission  fre-

quency (respectively 169 MHz and 868 MHz) 

and for the protocol used.

Arrow

WAN

 

169 uses the wM-Bus transmis-

sion protocol and also conforms to AFNOR 

E17Z v2.

Arrow

WAN

 

868 uses the LoRa protocol and is 

certified by LoRa Alliance®.

This guarantees a high level of interopera-

bility with various reading systems on the 

market, including third-party systems.

Содержание ArrowWAN

Страница 1: ...LLATION USE AND MAINTENANCE ArrowWAN Translation of the original instructions Before installing and using the device carefully read this manual and store it together with the product wM Bus 169 MHz ra...

Страница 2: ...Warranty limitations Maddalena S p A declines all responsibili ty with immediate invalidation of the war ranty in relation to Damage or defects caused by transport or loading unloading Incorrect insta...

Страница 3: ...ts where it will be exposed to atmospheric agents The device must always be pro tected from extreme humidity and heat Penetration of humidity and intense heat may damage the bat tery and the device If...

Страница 4: ...spose of the device as domestic waste 1 3 Device description ArrowWAN is a radio module with pulse input compatible with Maddalena water meters and with those of other brands The device allows for mea...

Страница 5: ...ole cable of the fol lowing signals pulses flow meter revo lutions flow direction anti fraud earth Thanks to this data the module calculates the volume both directions manages alarm situations and mem...

Страница 6: ...rrowWAN A ARROW 169 WAN Maddalena S p A Via G B Maddalena 2 4 33040 Povoletto UD IT P N 1 ETRMD 0670 S N MAD0078718707160 ARROW 169 WAN Maddalena S p A Via G B Maddalena 2 4 33040 Povoletto UD IT P N...

Страница 7: ...BW125 500 CR 4 5 ArrowWAN 169 WMBUS N2 a b c d e f Operating fre quency range ArrowWAN 868 863 at 876 MHz ArrowWAN 169 169 400 MHz at 169 475 MHz Radiated power 25 dBm max ArrowWAN 169 14 dBm max Arr...

Страница 8: ...anual is an inte gral part of the device and should be carefully read and stored d PROHIBITED Packaging material must be prop erly disposed of and kept out of children s reach as it may repre sent a h...

Страница 9: ...onnecting the wires The ArrowWAN module is supplied with a four pole cable with earth 1 White pulse input Pulse signal for both the delivery and return flow Yellow flow direction Contact closed return...

Страница 10: ...The radio module stores the volume record ed via an external sensor The module is set up in the factory with initial volume at zero If the meter on which the radio module is installed has a reading ot...

Страница 11: ...at the login 2 During activation 3 parameters are re quested the serial number of the mechani cal meter the pulse weight and the reading of the volume measured by the meter ex pressed in litres Once t...

Страница 12: ...mode l WARNING The Collect mode parameter is set by default to Fixed If module ArrowWAN 169 is activat ed the radio type can be set to Fixed AMR mode for fixed net work Mobile mobile reading mode or...

Страница 13: ...tion to verify that the module serial number reading and pulse weight values have been entered correctly From the Install menu click Summary 1 to view the information of the installed modules 2 1 2 Cl...

Страница 14: ...n failure No or difficult connec tion to the NFC port Place the smartphone so that its NFC port is above that of the radio module With some smartphones that have a weak NFC antenna the operation could...

Страница 15: ...ick on UNINSTALL 2 Place the smartphone above the radio module to allow the NFC communication Click on START UNINSTALL 3 1 2 3 Wait for the deactivation 4 to terminate 4 Once completed the Uninstall s...

Страница 16: ...e electronic board in stand by mode transmitter consumption and num ber of transmissions performed Battery life depends largely on the frequen cy of data transmission set 4 2 Cleaning No particular cl...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...right to change its products at any time and without prior notice with the aim of improving them and without compromising primary features All the graphic illustrations and or photographs appearing i...

Отзывы: