background image

16

4  Maintenance

4.1  Battery

The radio module is equipped with a 3.6 V 

lithium-thionyl chloride (Li-SOCl2) battery 

that is not rechargeable but can be replaced.

Its useful life varies between 12 

(

Arrow

WAN

 MVM 169  mobile  +  fixed)  and 

15 years (

Arrow

WAN

 MVM 169  fixed,  three 

transmissions per day of the measurements 

plus one weekly transmission on the status 

of the module) with the factory set up in the 

following operating conditions:

–  between  -10°C  and  +0°C  for  10%  of 

lifespan

–  between 0°C and +30°C for 80% of lifespan

–  between  +31  °C  and  +55  °C  for  10%  of 

lifespan

WARNING!

Humidity and intense heat may 

damage the battery and reduce 

its lifespan.

The radio module calculates the residual 

lifespan of the battery on the basis of stored 

parameters, such as estimated consump-

tion of the electronic board in stand-by 

mode, transmitter consumption and num-

ber of transmissions performed.

Battery life depends largely on the frequen-

cy of data transmission set.

4.2  Cleaning

No particular cleaning procedures are 

required. However, the installation area 

should be kept clean and periodic checks 

should be performed to ensure the re-

quired environmental conditions are met.

PROHIBITED

Use of abrasive products, petrol 

or trichloroethylene is not per-

mitted.

4.3  Disposal

The device is composed of materials of vari-

ous nature including metal, plastic and elec-

trical and electronic components. It must be 

disposed of in compliance with applicable 

local laws regarding special and industrial 

waste. The device cannot be disposed of as 

domestic waste.

At the end of the product’s life, ensure safe 

removal and responsible disposal of com-

ponents, including recycling of batteries, in 

compliance with applicable environmental 

laws in the country of installation.

Содержание ArrowWAN MVM wM-Bus 169

Страница 1: ...LATION USE AND MAINTENANCE ArrowWAN MVM Translation of the original instructions Before installing and using the device carefully read this manual and store it together with the product wM Bus 169 MHz...

Страница 2: ...a it Warranty limitations Maddalena S p A declines all responsibili ty with immediate invalidation of the war ranty in relation to Damage or defects caused by transport or loading unloading Incorrect...

Страница 3: ...ts where it will be exposed to atmospheric agents The device must always be pro tected from extreme humidity and heat Penetration of humidity and intense heat may damage the bat tery and the device If...

Страница 4: ...n line with applicable laws Do not dispose of the device as do mestic waste 1 3 Device description ArrowWAN MVM is a compact radio module for Maddalena series MVM and MVM Plus C water meters that enab...

Страница 5: ...design are internal sensor that identifies rotation of the pointer on the meter using the prin ciple of induction immune to magnetic interference calculates the volume in both directions manages alarm...

Страница 6: ...module ArrowWAN MVM 2 3 4 ARROW MVM169 WAN Maddalena S p A Via G B Maddalena 2 4 33040 Povoletto UD IT S N MAD0078799444444 P N 1 ETRMD 0601 1 1870028654 ARROW MVM169 WAN Maddalena S p A Via G B Madd...

Страница 7: ...SF7 12 BW125 500 CR 4 5 ArrowWAN MVM 169 WMBUS N2 a b c d e f Frequency ArrowWAN MVM 868 863 at 876 MHz ArrowWAN MVM 169 169 400 MHz at 169 475 MHz Range in an urban context ArrowWAN MVM 868 up to 3...

Страница 8: ...nd stored d PROHIBITED Packaging material must be prop erly disposed of and kept out of children s reach as it may repre sent a hazard Disposal must be performed in line with applicable laws 2 2 Fitti...

Страница 9: ...e relevant housing 2 Lower the module and offset it Attach the eyelet 3 to the catch 4 and realign the module 3 4 l WARNING Do not apply pressure to force the eyelet in Fasten the module using the scr...

Страница 10: ...e radio module stores the volume record ed via an inductive sensor The module is set up in the factory with initial volume at zero If the meter on which the radio module is installed has a reading oth...

Страница 11: ...peat the login 2 During activation 3 parameters are re quested the serial number of the mechani cal meter the pulse weight and the reading of the volume measured by the meter ex pressed in litres Once...

Страница 12: ...ode l WARNING The Collect mode parameter is set by default to Fixed If module ArrowWAN MVM 169 is activated the radio type can be set to Fixed AMR mode for fixed network Mobile mobile reading mode or...

Страница 13: ...tion to verify that the module serial number reading and pulse weight values have been entered correctly From the Install menu click Summary 1 to view the information of the installed modules 2 1 2 Cl...

Страница 14: ...s that have a weak NFC antenna the operation could be difficult or impossible Try with a different phone model Module activation error No or difficult connec tion to the NFC port Place the smartphone...

Страница 15: ...Click on UNINSTALL 2 Place the smartphone above the radio module to allow the NFC communication Click on START UNINSTALL 3 1 2 3 Wait for the deactivation 4 to terminate 4 Once completed the Uninstall...

Страница 16: ...f the electronic board in stand by mode transmitter consumption and num ber of transmissions performed Battery life depends largely on the frequen cy of data transmission set 4 2 Cleaning No particula...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...right to change its products at any time and without prior notice with the aim of improving them and without compromising primary features All the graphic illustrations and or photographs appearing i...

Отзывы: