Chapter 6 - Network Management

LED Indicators

The hub's front panel contains indicators called light emitting diodes or LEDs.

LEDs are used to make a quick diagnostic of the network's status. They allow
users to know, at a glance, what problems the network is encountering. 

Various LEDs, related to different functions, are displayed on the front panel.

There are five types of LEDs:

- PWR indicator:

(For FDH-608/FDH-616)

Color : Green

Label : Power

This indicator lights up in green whenever the hub is connected to the wall

adapter. If the green light fails to shine steadily, contact your dealer.

- 10M COL indicator:

(For FDH-608/FDH-616)

Color : Yellow

Label : Collision

- 100M COL indicator:

(For FDH-608/FDH-616)

Color : Yellow

Label : Collision

A collision occurs whenever two end nodes are sending data at the same time

on the network. Collisions are frequent in a Fast Ethernet network. When a colli-
sion occurs, the two end nodes that are attempting to transmit data simultaneously
back off and try again at different time intervals. 

However, if collisions are too frequent, this may be a sign of:

- Network overload

- Device malfunction

- Cabling problems

Network Management

21

Содержание FDH-608/616

Страница 1: ...1 User s Manual Dynamic Dual Speed Hub FDH 608 616 R acsense...

Страница 2: ...rds 7 Cables Required 7 Chapter 4 How to Configure a Fast Ethernet Network 9 Cable Length 9 Uplinking 9 Different Network Topologies 10 Other Ways to Expand a Network 11 Chapter 5 How to Install a Hub...

Страница 3: ...in a routing table The information on this routing table helps to identify the traffic and directs fast 100BASE TX or slow 10BASE traffic to the proper repeater buses By separating the two repeater bu...

Страница 4: ...e RJ 45 ports using Category 5 UTP UTP 5 Category 1 STP STP 1 for 100BASE TX or Category 3 4 5 UTP UTP 3 4 5 Category 1 STP STP 1 or equiva lent cables for 10BASE T We recommend starting from the high...

Страница 5: ...er Switch Repeater hub Individual port status LEDs for LINK RX 10 100 PAR and 10 100 Collision status LEDs General Features of FDH 616 16 Port Dual Speed Stackable Hub Compliant with the IEEE802 3 10M...

Страница 6: ...EIA designation Each jack serves to connect a cable to the network device The jack label 1X is designated as an uplink jack Uplink jacks are designed for connections to other network devices 4 8 3 7...

Страница 7: ...hat s more these stackable hubs break Fast Ethernet s two hub cascade barrier allowing you to link up to three hubs via the built in stack ports using any combination of these hub models These Dual Sp...

Страница 8: ...ions occur when two or more nodes accidentally attempt to transmit data across the network at the same time This happens more often with increased traf fic Naturally when you have more packets traveli...

Страница 9: ...lisioned nodes to prevent further disruption of the network Showing whether each network node is currently connected and idle trans mitting data or in 10BASE T 100BASE TX mode However according to the...

Страница 10: ...and Fast Ethernet Standards Standards for Ethernet and Fast Ethernet systems are issued by the Institute of Electrical and Electronic Engineers IEEE The standard for Ethernet twisted pair networks is...

Страница 11: ...ed pair UTP 3 4 5 or Category 1 shielded twisted pair STP 1 or any equivalent cable to transmit data 100BASE TX requires Category 5 unshielded twisted pair UTP 5 or Category 1 shielded twisted pair ST...

Страница 12: ...ion to each cable ensuring that no cable exceeds the length limit and that this length is well managed between end nodes and the hub Uplinking Uplinking a hub with another network expansion device suc...

Страница 13: ...ne device or it can used in a multiple device environment Standalone device When just one hub is being used in a network the hub is said to be a stand alone hub The hub can only be connected to users...

Страница 14: ...users may want to expand further improve network capabilities or integrate other networks Here is a brief introduction to the different ways of optimizing a network Dual Speed hubs Dual speed devices...

Страница 15: ...utomatically adjust itself to the power available Humidity The hub and indeed the entire network should be located in the driest area possible Humid places should be avoided as humidity can damage the...

Страница 16: ...led near a power outlet preferably one located in a position that is central to all network end nodes Hardware The availability of all connectors and cables required to install the hub and network sho...

Страница 17: ...nnections Use UTP 5 or STP 1 cables for 100BASE TX connections 2 Connect UTP Cable to the uplink port of the Hub then to a regular port on the Dual Speed Stackable Hub FDH 608 or FDH 616 The figure be...

Страница 18: ...an easily meet the networking needs of most small to medium sized workgroups As your workgroups gradually expand just add more hubs to your stack or cascade to another hub or switch using ordinary str...

Страница 19: ...st Ethernet Hub this protective cover cannot close properly Therefore this cover is designed with a brake away part to provide space for the MII cable to pass through 1 Locate the MII Port on the righ...

Страница 20: ...ng plugged into the end node s adapter it should be plugged into the hub s selected jack The following cable requirements should be remembered before proceeding with connections Cables must be of a UT...

Страница 21: ...ll shine steadily The hub will then automatically test each port connection The end node must be turned on for the test to succeed If the end node is not turned on the port will indicate a connection...

Страница 22: ...never the hub is connected to the wall adapter If the green light fails to shine steadily contact your dealer 10M COL indicator For FDH 608 FDH 616 Color Yellow Label Collision 100M COL indicator For...

Страница 23: ...dicator For FDH 608 Color Green Label Link One link LED is displayed for each port on the hub This indicator shows whenever the hub is receiving information When data is reaching the hub this indicato...

Страница 24: ...ed to see if it is defective Length limits Remember that the length limit for a connection between an end node and a hub cannot exceed 100 meters Cable being used for the connection Straight through c...

Страница 25: ...sure that all cables from node to node do not exceed the recom mended maximum length of 100 meters Checking the quality of the cables and outlets used to connect the hub to end nodes and to the wall a...

Страница 26: ...104 F Storage 25 C to 70 C 13 F to 158 F Humidity 5 to 95 non condensing Net Weight 900g 1 98lbs FDH 616 Standards IEEE 802 3 10BASE T IEEE 802 3u 100BASE TX Ports 16 x 10BASE T 100BASE TX ports and...

Страница 27: ...ticular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to cor...

Отзывы: