background image

4

03062022V14IFU122500

MacroMedics ® 

Manual

Instructions for use

  BreastBoards & ThoraxSupports

1.  Warnings

•  Inspect the device thoroughly before use. Do not use the device if damaged or incomplete.

•  Check individual components on MR-Safety when used together in a patient positioning system.

•  Do not use MR Unsafe items in an MR environment.

•  Prevent the surface from damage and scratching.

•  Secure the device properly before positioning the patient.

•  The device shall not extend from the cranial side of the couch.

•  Do not exceed the allowable maximum patient weight of 150 kilograms.

•  Rulers on the devices are only intended for reference of the device positioning of accessories. Rulers 

shall not replace patient position verifi cation.

•  Instruct the patient to lay down calmly and not to reposition themself after set-up.

•  Prevent the formation of closed-loops as they can lead to MRI burns. 

       Use an isolator between the patient’s arms to avoid skin-to-skin contact.

•  When used for proton treatment, ensure that the devices are not in the incoming 

        radiation-treatment-beam pathway. 

•  In the USA, federal law restricts this device to sale by or on the order of a licensed healthcare 

practitioner.

2.  MRI Safety Information

2.1

    MR UNSAFE

           The following devices are MR Unsafe:

•      122100  ThoraxSupport™

•      122300  Upper AS TS/MBLX, set/2

•      122320  Rotatable armrest LV, set/2

•      122330  Cranial AS for BBLX/TS, set/2

• 

    122380  Profi les LB1, set/10

• 

    122390  Profi les LB1, set/2

•      122520  WedgeThoraxSupport™

•      122540  HighBridgeSupp. TS/MBLX

•      122610  ThoraxSupport™ complete

•      122650   ThoraxSupport™ short

•      122670  90D ArmSupports TS

•      122730  Handpole MBLX-LB1

•      122760  Handpoles with armcup

• 

    122350  Profi les BreastBoardLX™ set/10

• 

    122360  Profi les BreastBoardLX™, set/2    

•      122500  BreastBoardLX™

•      122590   BottomStop Adaption

•      126140  OmniBoard™ BTM-SX-EX   

•      126160  OmniBoard™ bottomstop

  

•      172400  BreastBoardSX™, RAS

•      172410  BreastBoard SX™

• 

    172420  Profi les BreastBoardSX™, set/2      

•      172450  BreastBoardSX™, HAS

•      172110  FlexBoard™ base

•      172120  FlexBoard™ BTM-EX

•      172130  OmniBoard™ BTM-EX

•      173600  OmniBoard™ BTM-LX

•      173660  FlexBoard™ BTM-LX

•      174540  OmniBoard™ BTM-SX-RE

•      174630  FlexBoard™ BTM-SX

•      175010  OmniBoard™ BTM-SX-S  

Содержание BreastBoards

Страница 1: ...dics BV Oostbaan 670 2841ML Moordrecht The Netherlands 31 0 182 389777 info macromedics com www macromedics com MacroMedics BreastBoards ThoraxSupports MANUAL 122500 Instructions for use English Instr...

Страница 2: ...2 03062022V14IFU122500 MacroMedics Manual Instructions for use BreastBoards ThoraxSupports This page is intentionally left blank...

Страница 3: ...ts 3 03062022V14IFU122500 MacroMedics Table of Contents 1 Warnings 4 2 MRI Safety Information 4 3 Intended Use and Indications for Use 5 4 Installation Instructions 6 5 Cleaning Storage and Disposal 1...

Страница 4: ...When used for proton treatment ensure that the devices are not in the incoming radiation treatment beam pathway In the USA federal law restricts this device to sale by or on the order of a licensed h...

Страница 5: ...magnetic eld of 1 5 Tesla and 3 Tesla with Maximum spatial eld gradient of 2 500 G cm 25 T m Maximum force product of 50 000 000 G cm 50 T2 m Due to size and location of the metallic parts no clinica...

Страница 6: ...ates at the caudal end of the BreastBoard Module with the slots in the predestined board and slide the BreastBoard in the slots Carefully lower the Cranial end of the BreastBoard towards the OmniBoard...

Страница 7: ...t is possible between the CouchStrip and the couch For more information refer to IFU147100 CouchStrips and Sidepieces The CouchStrips can be screwed onto the baseplate for convenience For the usage in...

Страница 8: ...s of the BreastBoards and ThoraxSupports for accurate patient positioning and record the positions in the corresponding Set Up sheet The Armsupports The armsupports can be adjusted in one direction Th...

Страница 9: ...ber pro les for the Breast Mask in the desired position on the sides of the BreastBoard and lock them with Quickfasteners Refer to the Thermoplastic Masks IFU117000 for instructions on pro le assembl...

Страница 10: ...Slide the EagleBoard 2 towards the caudal side and lock it by turning the lock knobs counterclockwise Turn the lock knobs back in clockwise direction to loosen For adjustment of the EagleBoard 2 in lo...

Страница 11: ...pports 11 03062022V14IFU122500 MacroMedics Turn the grip knobs clockwise to lock the EagleBoard 2 on the desired indexed position Align the M Grip with the rails on the EagleBoard 2 Push the white loc...

Страница 12: ...cs Manual Instructions for use BreastBoards ThoraxSupports Place the M Grip on the desired indexed position and release the lock knobs to x the M Grip to the rails of the OmniBoard EX Place the HeadSu...

Страница 13: ...ore the device in a clean ventilated environment Dispose of the device in accordance with the local laws and regulations applicable to your country 6 Warranty The MacroMedics products are warranted to...

Страница 14: ...for use Caution Indicates the need for the user to consult the instructions for use for important cautionary information such as warnings and precautions that cannot for a variety of reasons be prese...

Страница 15: ...Manual Instructions for use BreastBoards ThoraxSupports 15 03062022V14IFU122500 MacroMedics This page is intentionally left blank...

Страница 16: ...MacroMedics BV Oostbaan 670 2841ML Moordrecht The Netherlands 31 0 182 389 777 info macromedics com www macromedics com Visit www macromedics com for a digital copy of this manual...

Отзывы: