44
GM
390
210
M 4x16 max.
1,5 Nm
M 4x
5
max.
2,5 Nm
A
B
C
A
4
3
2
1
Trafo
Braun -
+
_
1
Weiß +
2
**
**
44
WINDOWS ·
DOORS
· SLIDING DOORS
Loop for
Assembly
openDoor Access Solutions
Somfy lock controller
A
Motor cable connection
B
Power supply 12 - 24 V DC
min. 1.5 A
C
Tension release
12 - 24V DC
min. 1.5 A
Electrical connections (connection of power supply, connection cable 0.15 m and 10 m) may only be car-
ried out by authorised personnel!
Plug & Play connector /
cable installation
1
Brown: motor operating voltage
minus -
2
White: motor operating voltage
plus +
3
Green: control voltage* minus -
4
Yellow Control voltage * plus +
* The control voltage is required for push-button
(button impulse) and toggle switch (activation/
deactivation of day-release)!
DIP switch
DIP switch 4 ON = IN1 / IN 2 Locking monitoring ON
OFF = IN1 / IN 2 Locking monitoring OFF
DIP switch 5 ON = 3 sec. exit activation 1/2
OFF = 1 sec. exit activation 1/2
Connections
1 GND
2 V in +8 - 24V (DC)
= supply power
3 IN COM
4 IN closed
5 IN double locked
= Isolated free inputs (max. load 24V / 10mA)
6 OUT 1A
7 OUT 1B
= Isolated free outputs 1 (max. load 24V / 600mA)
8 OUT 2A
9 OUT 2B
= Isolated free outputs 2 (max. load 24V / 600mA)
Содержание A-TS Series
Страница 53: ...53 53 WINDOWS DOORS SLIDING DOORS Notes...
Страница 54: ...54 54 WINDOWS DOORS SLIDING DOORS Notes...
Страница 55: ...55 55 WINDOWS DOORS SLIDING DOORS Notes...