TROUBLE SHOOTING GUIDE

Relieve the pressure before you check or repair the dispensing valve. Be sure all other valves 

and controls and the pump are operating properly.

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always 

follow the pressure relief procedure on page 3.

E7

TECHNICAL

DETAILS

EXPLODED AND

PARTS LIST

INSTALLATION

MAINTENANCE

DETAILS OF OPERATION

TROUBLE 

SHOOTING GUIDE

LIMITED

WARRANTY

Problem

Slow or no fluid flow

Oil leaks from swivel

Oil drips from nozzle

Valve leaks

Leakage from meter

No Display

Wrong Reading

Problem

Filter is clogged, or pump pressure is 

low, or shut-off valve is not fully open, 

or foreign materialis jammed in the 

metering element.
Swivel is loose

O-ring is worn or damaged

Nozzle is damaged or obstructed

O-rings or valve seat are worn or 

damaged

O-ring damaged

Loosing Battery

Battery out of power

Correction coefficient error

Solution

1. Relief the pressure.

2. Loose swivel fitting, clean or replace the filter.

3. If the problem remains, contact your

distributor for repair or replacement.

Torque the swivel.

If the problem remains, contact your distributor 

for repair or replacement.
Replace the o-ring.

If the problem remains, contact your distributor 

for repair or replacement.
Inspect the nozzle for damage or obstructions,

and replace if damaged.

If the problem remains, contact your distributor 

for repair or replacement.
Replace the o-rings and/or the valve seat.

If the problem remains, contact your distributor 

for repair or replacement.
1. Get the meter off from the dispense system.

2. Take off the protector.

3. Loosing four the socket head cap screws on 

the cover of the meter.

4. Loosing eight the hex bolts on the bottom of 

the meter.

5. Take off the seat.

6. Check the o-ring, replacing the o-ring if it is

damaged.

7. After replacing the o-ring, assemble the meter

and fix it back to the dispense system.

1. Get the meter off from the dispense system

2. Take off the protector.

3. Take off the labels sticks on the bottom of the

meter.

4. Loosing the five socket head cap screws on 

the bottom of the meter.

5. Take off the seat.

6. Check the battery, replacing the battery if it is

out of power.

7. After replacing the battery, assemble the 

meter and fix it back to the dispense system.

Reset the correction factor (follow the 

instructions on Page 6).

WARNING: 

Your risk from these exposures varies, depending on how often you 

do this type of work. To reduce your exposure to these chemicals: work in a well 

ventilated area, and work with approved safety equipment, such as those dust 

masks that are specially designed to filter out microscopic particles.

Содержание OCVF-001

Страница 1: ...fore operating Failure to follow the safety rules and other basic safety precautions may result in serious personal injury Save these instructions in a safe place and on hand so that they can be read...

Страница 2: ...ere are certain applications for which this equipment was designed It will do the job better and more safely at the capacity for which it was intended Do not modify this equipment and do not use this...

Страница 3: ...rection factor to decide the right connection factor then set the proper correction factor refer to 3 Button usage part Once the meter has been installed please make sure that no air pressure shocks o...

Страница 4: ...the move key entering instrument calibration mode Used together the two keys permit entering configuration mode BATTERY REPLACEMENT When replacing the battery please open the cover remove the plug and...

Страница 5: ...tor which can be reset 1234567 is the general total which cannot be reset Measurement unit change See Fig 6 Press MOVE and RESET together and hold for more than 3 seconds Zone 7 on the display is the...

Страница 6: ...Proper correction factor 1 000 20 75 18 96 1 000 1 094 1 094 1 2 3 4 5 Wait for the meter to go standby Reset the resettable total Press the MOVE key Keep it pressed until it shows similar to the rig...

Страница 7: ...ut the actual value The volume that is displayed on the LCD is the Display Value not the Actual Value which may be slightly higher For example in the figure on the right the Display Value is 18 96 whi...

Страница 8: ...ase your hand the transmission will be finished Notes When Using Cautions 1 For working condition please refer to the specification parameter list Temperature 10 C 60 C 2 Media Lubricant Oil OIL CONTR...

Страница 9: ...contact your distributor for repair or replacement Inspect the nozzle for damage or obstructions and replace if damaged If the problem remains contact your distributor for repair or replacement Replac...

Страница 10: ...caused by accident misuse or faulty installation 4 The product must be installed and maintained in compliance with the instructions EXPLODED AND PARTS LIST METER Part No 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2...

Страница 11: ...1 1 Part No 4 10 4 11 4 12 4 13 4 14 4 15 4 16 4 17 4 18 Description Washer Seal Slip Pole O Ring O Ring Bushing O Ring O Ring Piston Sleeve Q ty 1 1 1 1 1 1 1 1 1 Wearing Parts E9 TECHNICAL DETAILS...

Страница 12: ...Macnaught Americas 813 628 5506 info macnaughtusa com Read Manual Before Use...

Отзывы: