2. CHANGE THE BATTERY

• Battery type: Lithium CR2, 3V/1400mAh.

• Change the battery like below when the battery signal is flashing on the display.

• Remove the protector cover, unscrewing the screw.

• Change the battery and screw the lid on again.

USER BUTTONS

The turbine digital meter features two buttons (MOVE and RESET) which individually perform 

two main functions and together, other secondary functions.

The main functions performed are:

For the reset key, resetting the partial Register and reset table total (reset total).

For the move key, entering instrument calibration mode.

Used together, the two keys permit entering configuration mode,

BATTERY REPLACEMENT

When replacing the battery, please open the cover, remove the plug and replace the battery. 

LCD DISPLAY

KEY

 Partial register (5 figures with moving comma from 0.1 to 99999)

Indicating the volume dispensed since the reset button was last pressed.

 Indication of battery charge

 Indication of calibration mode

 Indication of resetting present total to Zero

 Total register

 Indication of flow rate mode 

 Indication of unit of measurement of partial: L= Litres

GAL = Gallons

PT = Pints

QT = Quarts 

DAILY USE

BUTTON USAGE, CALIBRATION AND MEASUREMENT

UNIT CHANGE

• Reset the present total (See Fig. 4)

1) When the meter is on standby, press the RESET key.

2) The display shows all the segments.

3) The meter resets the present total already.

Fig. 4

Содержание OCVF-001

Страница 1: ...fore operating Failure to follow the safety rules and other basic safety precautions may result in serious personal injury Save these instructions in a safe place and on hand so that they can be read...

Страница 2: ...ere are certain applications for which this equipment was designed It will do the job better and more safely at the capacity for which it was intended Do not modify this equipment and do not use this...

Страница 3: ...rection factor to decide the right connection factor then set the proper correction factor refer to 3 Button usage part Once the meter has been installed please make sure that no air pressure shocks o...

Страница 4: ...the move key entering instrument calibration mode Used together the two keys permit entering configuration mode BATTERY REPLACEMENT When replacing the battery please open the cover remove the plug and...

Страница 5: ...tor which can be reset 1234567 is the general total which cannot be reset Measurement unit change See Fig 6 Press MOVE and RESET together and hold for more than 3 seconds Zone 7 on the display is the...

Страница 6: ...Proper correction factor 1 000 20 75 18 96 1 000 1 094 1 094 1 2 3 4 5 Wait for the meter to go standby Reset the resettable total Press the MOVE key Keep it pressed until it shows similar to the rig...

Страница 7: ...ut the actual value The volume that is displayed on the LCD is the Display Value not the Actual Value which may be slightly higher For example in the figure on the right the Display Value is 18 96 whi...

Страница 8: ...ase your hand the transmission will be finished Notes When Using Cautions 1 For working condition please refer to the specification parameter list Temperature 10 C 60 C 2 Media Lubricant Oil OIL CONTR...

Страница 9: ...contact your distributor for repair or replacement Inspect the nozzle for damage or obstructions and replace if damaged If the problem remains contact your distributor for repair or replacement Replac...

Страница 10: ...caused by accident misuse or faulty installation 4 The product must be installed and maintained in compliance with the instructions EXPLODED AND PARTS LIST METER Part No 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2...

Страница 11: ...1 1 Part No 4 10 4 11 4 12 4 13 4 14 4 15 4 16 4 17 4 18 Description Washer Seal Slip Pole O Ring O Ring Bushing O Ring O Ring Piston Sleeve Q ty 1 1 1 1 1 1 1 1 1 Wearing Parts E9 TECHNICAL DETAILS...

Страница 12: ...Macnaught Americas 813 628 5506 info macnaughtusa com Read Manual Before Use...

Отзывы: