INSTALLATION
1. Use thread sealant on all pipe threads.
2. Ensure the meter is installed so that rotor shafts
are always in a horizontal plane.
Flow is bi-directional.
3.The use of flexible connections is recom-
mended
.
4. Extreme care must be taken when installing
the meter. Pipe strain or over tightening meter
connections can cause meter damage.
PULSER DETAILS
Hall Effect Sensor Specifications
1 - 4.5V to 24V (4.6 ~ 9mA) operation needs only
an unregulated supply.
1 - Open collector 25mA output NPN (Current
Sink) compatible with digital logic.
1 - Reverse battery protection.
Reed Relay Specifications
1 - Two wire SPST N/O.
1 - Switching voltage 150VDC maximum
current 0.25 AMPS.
1 - Rating 3 watts.
1 - Duty cycle 20% on 80% off.
MAINTENANCE
Disassembly
1. Ensure the fluid supply to the meter has been
disconnected, and the line pressure has been
released before disassembly.
2. Remove four (4) screws (Item 3) and remove the
meter cap (Item 2).
3. Remove o-ring (Item 5) and inspect (replace o-ring
if damaged).
4. Remove rotors (Item 4), clean and inspect
(replace rotors if damaged).
Reassembly
1. Place rotors (Item 4) into the meter body. The
rotors should be at 90 degrees to each other.
Note: The rotor with magnets must be placed in the
body on the same side as the groove on the body
(refer to diagram).
2. Lightly rotate the rotors (Item 4) by hand (they must
rotate freely).
3. Install o-ring (Item 5).
4. Replace the meter cap (Item 2).
Note: The groove on the cover must line up with
the groove on the meter body (refer to diagram).
5. Replace four screws (Item 3).
CAUTION:
Care must be taken not to over tighten the screws
(Item 3) or damage may occur.
1 - Temperature -40dgr C / -40dgr F ~ 150dgr
C/ 300dgr F.
1 - Temperature -40dgr C / -40dgr F ~ 150dgr
C/ 300dgr F.