background image

 

 

 

 

999565 – Revision A 

 

P a g e

 | 

16 of 32

 

 

P3 

CA800PP3 

CA800MP3 

CA800SP3 

CA800PAP3 

P4 

CA800PP4 

CA800MP4 

CA800SP4 

CA800PAP4 

P5 

CA800PP5 

CA800MP5 

CA800SP5 

CA800PAP5 

X Small 

CA800PXS 

CA800MXS 

CA800SXS 

CA800PAXS 

Small 

CA800PS 

CA800MS 

CA800SS 

CA800PAS 

Small/Medium 

CA800PSM 

CA800MSM 

CA800SSM 

CA800PASM 

Medium 

CA800PM 

CA800MM 

CA800SM 

CA800PAM 

Medium/Large 

CA800PML 

CA800MML 

CA800SML 

CA800PAML 

Large 

CA800PL 

CA800ML 

CA800SL 

CA800PAL 

X Large 

CA800PXL 

CA800MXL 

CA800SXL 

CA800PAXL 

XX Large 

CA800PXXL 

CA800MXXL 

CA800SXXL 

CA800PAXXL 

CA801 Chest Sling 

P1 

CA801PP1 

CA801MP1 

CA801SP1 

CA801PAP1 

P2 

CA801PP2 

CA801MP2 

CA801SP2 

CA801PAP2 

P3 

CA801PP3 

CA801MP3 

CA801SP3 

CA801PAP3 

P4 

CA801PP4 

CA801MP4 

CA801SP4 

CA801PAP4 

P5 

CA801PP5 

CA801MP5 

CA801SP5 

CA801PAP5 

X Small 

CA801PXS 

CA801MXS 

CA801SXS 

CA801PAXS 

Small 

CA801PS 

CA801MS 

CA801SS 

CA801PAS 

Small/Medium 

CA801PSM 

CA801MSM 

CA801SSM 

CA801PASM 

Medium 

CA801PM 

CA801MM 

CA801SM 

CA801PAM 

Medium/Large 

CA801PML 

CA801MML 

CA801SML 

CA801PAML 

Large 

CA801PL 

CA801ML 

CA801SL 

CA801PAL 

X Large 

CA801PXL 

CA801MXL 

CA801SXL 

CA801PAXL 

XX Large 

CA801PXXL 

CA801MXXL 

CA801SXXL 

CA801PAXXL 

CA900 Transport Sling 

P1 

CA900PP1 

CA900MP1 

CA900SP1 

CA900PAP1 

P2 

CA900PP2 

CA900MP2 

CA900SP2 

CA900PAP2 

P3 

CA900PP3 

CA900MP3 

CA900SP3 

CA900PAP3 

P4 

CA900PP4 

CA900MP4 

CA900SP4 

CA900PAP4 

P5 

CA900PP5 

CA900MP5 

CA900SP5 

CA900PAP5 

X Small 

CA900PXS 

CA900MXS 

CA900SXS 

CA900PAXS 

Small 

CA900PS 

CA900MS 

CA900SS 

CA900PAS 

Small/Medium 

CA900PSM 

CA900MSM 

CA900SSM 

CA900PASM 

Medium 

CA900PM 

CA900MM 

CA900SM 

CA900PAM 

Medium/Large 

CA900PML 

CA900MML 

CA900SML 

CA900PAML 

Large 

CA900PL 

CA900ML 

CA900SL 

CA900PAL 

X Large 

CA900PXL 

CA900MXL 

CA900SXL 

CA900PAXL 

XX Large 

CA900PXXL 

CA900MXXL 

CA900SXXL 

CA900PAXXL 

 

 

 

 

 

Table 4

 

Содержание SA400

Страница 1: ...Doc No 999565 Revision of document A Revision Date 20 04 21 User Manual SA400 Stand Aid...

Страница 2: ...3 3 Stand Aid Assembly 10 3 4 Electrical Connections 11 Final Inspection 11 Operating Instructions 12 5 1 Manoeuvring the Stand Aid 12 5 2 Raising and Lowering 12 5 3 Open Close Stand Aid Legs 12 5 4...

Страница 3: ...19 7 1 Normal Operating Conditions 19 7 2 Shipping and Storage Conditions 19 Disposal 19 Fault Finding 20 General Inspection Maintenance and Cleaning 21 10 1 Service 21 10 2 Inspection 21 10 3 Cleanin...

Страница 4: ...it to the manufacturer and to your national authority Store this manual with the documents included with the Stand Aid and sling s Contents of this manual are subject to change without prior written n...

Страница 5: ...ons before use Caution see instructions for use Manufacturer Safe Working Load represents the maximum load rated for safe operation Packaging indicator This way up Date of manufacture Serial number Pa...

Страница 6: ...support and promote safe patient handling and transfer for both the patient and carer The Stand Aid is one of two components that makes this possible The other component the sling is a specially desig...

Страница 7: ...Stand Aid In areas where children are prone to be present be vigilant when carrying out a transfer To reduce the risk of unintended use when the Stand Aid is not in use remove the sling s from the pr...

Страница 8: ...e provided on the last page of this manual Item Description Item Description 1 Handle 11 Knee Pad Length Adjustment 2 Mast 12 Knee Pad Angle Adjustment 3 Lifting Arm 13 Star Handle Mast Fixture 4 Loop...

Страница 9: ...ial performance of the Stand Aid and to avoid unnecessary damage or injuries to people within the area of the Stand Aid The environment in which the Stand Aid is situated in whilst carrying out a tran...

Страница 10: ...emove Star handle from the top of the base and slot the mast and boom assembly onto the base As shown in Fig 2 and 3 E Ensure all cables are clear from entrapment while fitting the base and mast toget...

Страница 11: ...rm all cables are located and secure Ensure the red emergency stop button on the control box is deactivated Rotate clockwise to release if required Refer to section 5 4 for guidance Press the up butto...

Страница 12: ...ion by applying a single brake lateral movement and parking To apply the brake press the brake pedal down with your foot as shown in Fig 12 To release the brake press the raised pedal towards the whee...

Страница 13: ...worth Service Provider 5 5 2 Electrical Emergency Lowering The Stand Aid lifting arm can be lowered by pushing the emergency lowering button on the control box with a suitable object such as a pen nib...

Страница 14: ...tery Pack The battery pack can be recharged via mains lead terminated with a figure of eight plug A Fit the mains lead figure of eight plug into charger link cable see Fig 22 B Plug the 2 pin mains pl...

Страница 15: ...uct codes For all components the lowest maximum safe working load must always be adhered to Size Mackworth Sling Range Product Material and Code Polyester Solid Holly Stand Aid Transport Sling XS 1201...

Страница 16: ...CA801PXS CA801MXS CA801SXS CA801PAXS Small CA801PS CA801MS CA801SS CA801PAS Small Medium CA801PSM CA801MSM CA801SSM CA801PASM Medium CA801PM CA801MM CA801SM CA801PAM Medium Large CA801PML CA801MML CA...

Страница 17: ...999565 Revision A P a g e 17 of 32 TECHNICAL SPECIFICATION 6 1 Mackworth SA400 Dimensions All dimensions below are shown in millimetres Figure 27 Figure 28...

Страница 18: ...AC 50 60Hz Charger rated output 27 4 29 0 VDC 0 8A Electric Shock Protection Charger Class II Lift internal power source Degree of shock protection Type B Lift internal power source Duty cycle 10 Use...

Страница 19: ...its intended use safely the Stand Aid must be decommissioned by an approved Service Engineer The following specifies the importance of correct disposal procedure including local laws and being enviro...

Страница 20: ...and breaks Inspect the Control Box terminals for any damage e g burns and breaks Stand Aid doesn t lift Check if the Stand Aid is plugged into Charge Stand Aid will not raise and lower while on charge...

Страница 21: ...or service of your Stand Aid Notice any change in the performance Want to report an unexpected occurrence Want to arrange a service Need to ascertain necessary information for replacement parts and c...

Страница 22: ...into the base housing Check the operation of the mast locking hand wheel Check the actuator mounting brackets for excessive wear Boom Check the attachment of the boom to the mast ensure all fixing po...

Страница 23: ...al Clean 200 5 1 32gal 1 1 Dirty 1000 1 0 26gal 1 5 Fungicidal Clean 2000 1 0 26gal 2 15 Dirty 5000 1 0 26gal 5 15 Mycrobactericidal Clean 1000 1 0 26gal 1 15 Dirty 5000 1 0 26gal 5 15 Virucidal Clean...

Страница 24: ...nship Excluding Batteries 2 The liability of Mackworth under terms of this guarantee shall be limited to the replacement or the defective part s to the sales distributor dealer agent person or entity...

Страница 25: ...999565 Revision A P a g e 25 of 32 SERVICE RECORD HISTORY Complete this section after each service repair inspection and or maintenance...

Страница 26: ...999565 Revision A P a g e 26 of 32...

Страница 27: ...999565 Revision A P a g e 27 of 32...

Страница 28: ...999565 Revision A P a g e 28 of 32...

Страница 29: ...999565 Revision A P a g e 29 of 32...

Страница 30: ...999565 Revision A P a g e 30 of 32 User notes...

Страница 31: ...999565 Revision A P a g e 31 of 32 User notes...

Страница 32: ...y errors or omissions Prism Medical operates a policy of continuous improvement Specifications and other data are subject to change without notice Dealer service contact details Manufacturer contact d...

Отзывы: