background image

 

 

 

999061 – Revision A 

 

P a g e

 | 

10 of 28

 

4.2

 

Adjusting Knee/shin Pad (Double Knee Pad) 

1.

 

On the rear face of the product release the Knee/shin pad from its current location by pulling on the black locking 

plungers and the same time. (see Figure 11) 

2.

 

After releasing the knee/shin pad from its current location, it is now free to move up are down to the new preferred 

height for the patient. (see Figure 12) 

3.

 

Once you are happy with the new position of the pad, simply release the black locking plungers by letting go of them 

both at the same time. (see figure 13) 

4.

 

To adjust the individual pads inwards and outwards, using your hand slide each pad by pushing inwards or outwards to 

suit the need for the patient. (see figure 14 & 15) 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.3

 

Applying the brakes 

To operate the Raiser Transfer Aid brakes, in the following way to activate and deactivate the brakes: 

 

1.

 

To activate the brakes, take your foot or hand and push down vertically on the red cycle on the brake leaver, one brake 

leaver at a time. (see figure 16 & 18) 

 

2.

 

To deactivate the brakes, Take your foot or hand and push forward on the green dot on the brake leaver, one brake 

lever at a time. (see figure 17 & 18) 

 

 

 

 

 

 

 

 

 

 

 

Figure 18

 

GREEN 

RED 

Figure 17

 

Figure 16

 

Figure 11

 

Figure 12

 

Figure 13

 

Figure 14

 

Figure 15

 

Содержание Raiser

Страница 1: ...Doc No 999061 Revision of document A Revision Date 19 04 21 Raiser Transfer Aid User Manual...

Страница 2: ...ciples 11 5 1 Standing a user who requires no assistance 11 5 2 Standing a user who requires assistance with optional Ladder belt 11 5 3 Standing a user who requires assistance with the optional safet...

Страница 3: ...ts use a serious incident has occurred please report it to the manufacturer and to your national authority Store this manual with the documents included with the Transfer Aid Contents of this manual a...

Страница 4: ...ons before use Caution see instructions for use Manufacturer Safe Working Load represents the maximum load rated for safe operation Packaging indicator This way up Date of manufacture Serial number Pa...

Страница 5: ...re safe use can be established The belt s is a specially designed fabric accessory that attaches to the Transfer Aid by means of the hooks on the rear face of the handle this holds and aids an individ...

Страница 6: ...ce be tampered with Between Transfer Aid and Belt the lowest maximum load shall always be used You may need to seek specialist advice on how to assist some people with specific moving and handling nee...

Страница 7: ...show the contents of the Transfer Aid If you have not received all the components contact Prism Medical UK dealer immediately contact details are provided on the last page of this manual Item Descript...

Страница 8: ...within the area of the Transfer Aid The environment in which the Transfer Aid is situated in whilst carrying out a transfer is required to be on a flat surface with no steep inclines 3 2 Unboxing Tra...

Страница 9: ...pad height on the raiser in the following way 1 On the rear face of the product release the Knee shin pad from its current location by pulling on the black locking plungers and the same time see Figur...

Страница 10: ...h at the same time see figure 13 4 To adjust the individual pads inwards and outwards using your hand slide each pad by pushing inwards or outwards to suit the need for the patient see figure 14 15 4...

Страница 11: ...ions to the user telling them to stand whilst they are counterbalancing the raiser 5 Once the user is stood the caregiver may release the brakes with one foot Pull the Mackworth Raiser backwards and t...

Страница 12: ...spine and the solid section is place under the user s coccyx 2 Fasten in place using the Velcro straps and adjustable buckle fastening support belt ensure support belt is at maximum length 3 The user...

Страница 13: ...EN ISO 10535 before its use The belts with a safe working load of 160kg that can be used with the Mackworth Raiser are shown below in Table 3 complete with product codes For all components the lowest...

Страница 14: ...999061 Revision A P a g e 14 of 28 6 0 TECHNICAL SPECIFICATION 6 1 Raiser Dimensions Single Knee Pad Figure 28 Figure 29 Figure 30...

Страница 15: ...999061 Revision A P a g e 15 of 28 6 2 Raiser Dimensions Double Knee Pad Figure 31 Figure 32 Figure 33...

Страница 16: ...le Double Knee Pad 9 kg Handle 5 5 kg Base 11 5 kg Table 5 Operational Forces Operating Force with 160 kg 100N Operating Force with 0 kg 8N Operation of the Brake 75N Sliding the Knee Pad Up 60N Slidi...

Страница 17: ...its life cycle and can no longer perform to its intended use safely the Aid must be decommissioned by an approved Service Engineer The following specifies the importance of correct disposal procedure...

Страница 18: ...ler immediately so the Transfer Aid can be checked to ensure proper continued operation Table 8 10 0 GENERAL INSPECTION MAINTANANCE AND CLEANING 10 1 Service No service is to be carried out on the Rai...

Страница 19: ...contact your local authorised dealer immediately Examine the sling hooks on the handle bar for excessive wear and sharp edges Handle Assembly Ensure that the Installation of the handle to base is corr...

Страница 20: ...dirty device This is also ideal for use after an outbreak of the Norovirus winter vomiting and can be used as a precaution against C Diff It is effective against viruses bacteria spores yeasts and mou...

Страница 21: ...heet For a full review of the data please follow the link below http www nhsggc org uk media 236215 msds actichlor plus pdf 11 0 WARRANTY This guarantee does not affect or in any way limit your Statut...

Страница 22: ...999061 Revision A P a g e 22 of 28 12 0 SERVICE RECORD HISTORY Complete this section after each service repair inspection and or maintenance...

Страница 23: ...999061 Revision A P a g e 23 of 28...

Страница 24: ...999061 Revision A P a g e 24 of 28...

Страница 25: ...999061 Revision A P a g e 25 of 28...

Страница 26: ...999061 Revision A P a g e 26 of 28 User notes...

Страница 27: ...999061 Revision A P a g e 27 of 28 User notes...

Страница 28: ...or omissions Prism Medical UK operates a policy of continuous improvement Specifications and other data are subject to change without notice Dealer service contact details Manufacturer contact detail...

Отзывы: